Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
MOTORES ELÉCTRICOS SECCIONADOS. MÓDULO AVANZADO Ref: 0492 ITEM 1 1 / 2 REFERENCIA DESCRIPCIÓN CANT. EMT-S MOTORES SECCIONADOS, COMPUESTO POR: 1 EMT-7BS MOTOR TRIFASICO DE JAULA ARDILLA (DOBLE) 1 EMT-10S MOTOR TRIFASICO SECCIONADO DE , 2 VELOCIDADES 1 EMT-14S MOTOR DE REPULSION 1 EMT-15S MOTOR C.C.DE IMANES PERMANENTES 1 EMT-17S MOTOR TRIFASICO DE JAULA DE ARDILLA CON CONEXIÓN "Y" 1 EMT-18S MOTOR BRUSHLESS 1 EMT-19S MOTOR PASO A PASO 1 EMT-20S MOTOR ASINCRONICO MONOFASICO DE FASE PARTIDA 1 EMT-21S MOTOR DE RELUCTANCIA 1 EMT-22S MOTOR MONOFÁSICO CON DEVANADO AUXILIAR EN CORTOCIRCUITO 1 2 0470PARTS COMPONENTES Y REPUESTOS 1 3 0470PA PARTIDA ALZADA 1 4 0470IYPM INSTALACIÓN Y PUESTA EN MARCHA 1 5 0470CAPRO CAPACITACIÓN Y ACTUALIZACIÓN DE PROFESORES 1 6 0470TD TÉCNICAS DIDÁCTICAS "KNOW-HOW" 1 7 0470MANU DOCUMENTACIÓN Y MANUALES 1 Ref: 0492 2 / 2 Notas: a)Opción de multipuesto: * Este módulo tiene una unidad solamente en cada item, nosotros podemos recomendar el número de unidades para que 10 o 30 estudiantes puedan trabajar simultáneamente. b)Condiciones de suministro: * Condiciones técnicas: - Adaptación de los laboratorios. - Instalación de todos los equipos. - Puesta en marcha de todos los equipos. - Entrenamiento de cada uno de los ejercicios a ser realizados con cada uno de los equipos. - Formación de profesores, relacionada con cada equipo didáctico y cada una de las técnicas de enseñanza aplicada. - Transferencia de tecnología. * Condiciones comerciales: - Embalaje. - Gastos de financiación. - Gastos C.I.F. * Otras condiciones: - 8 Manuales para cada uno de los equipos didácticos de EDIBON: . Manual de servicios requeridos. . Manual de montaje e instalación. . Manual de la interface y del software/consola de control. . Manual de puesta en marcha. . Manual de normas de seguridad. . Manual de prácticas. . Manual de mantenimiento. . Manual de calibración. Ver catálogos en las páginas siguientes 4.4- Electrical Machines (continuation) EMT-S. Cut Away Motors: Available cut away motors: -EMT1-S. -EMT2-S. -EMT3-S. -EMT4-S. -EMT5-S. -EMT6-S. -EMT7-S. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. -EMT8-S. Asynchronous three-phase motor with wound rotor. -EMT9-S. Dahlander three-phase (two-speeds). -EMT10-S. Asynchronous three-phase motor with two independent speeds. -EMT11-S. Asynchronous single-phase motor with starting capacitor. -EMT12-S. Universal motor (single-phase). -EMT14-S. Repulsion motor, single-phase with shortcircuited brushes. -EMT15-S. DC Permanent magnet motor. -EMT16-S. Asynchronous single-phase motor with starting and running capacitor. -EMT17-S. Three-phase motor of squirrel cage with “Y” connection. -EMT18-S. DC Brushless motor. -EMT19-S. Stepper motor. -EMT20-S. Asynchronous single-phase motor with split phase. -EMT21-S. Three-phase Reluctance motor. -EMT22-S. Single-phase Shaded Pole motor. ESAM. Faults Simulation Trainer in Electrical Motors More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAM.pdf PRACTICAL POSSIBILITIES 1.- Detection of fault on a phase. 2.- Detection of fault on the supply voltage. 3.- Coils with turns in short circuit. 4.- Measurement the resistance of the windings. 5.- Detection of open-ended coil. 6.- Detection of short circuit in coils from different phase. 7.- Measurement the resistance between coils from different phases. 8.- Detection of ground fault. 9.- Measurement of the insulation resistance between the winding and the motor case. 10.- Motor in star connection. 11.- Motor in delta connection. ESAE. Electrical Faults Simulation Trainer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. With this trainer the following troubles or faults, among others, may be fixed and determined: -Power off. -Fuse blown. -Defective main circuit broker. Defective leak current coil relay. -Ground fault. -Detection of fault on the supply voltage. -Capacitor:Starting capacitor open and run capacitor open, starting capacitor shorted and run capacitor shorted. -Thermostat contacts stuck open and closed. -Relay contacts stuck closed. Relay windings open. -Fan:Fan motor windings open and shorted. Fan relay windings open and shorted. Fan relay contacts stuck closed. Fan relay contacts are rusting. Fan thermostat contacts stuck closed. Fan thermostat sensor bulb stuck opened. -Motor: Starting motor windings open and shorted. Running motor windings open and shorted. -Compressor: Thermal overload open. Compressor motor winding grounded. -Low voltage. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 400 x 330 x 400 mm. approx. Weight: 10 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAE.pdf EEA. Alternators Study Unit SPECIFICATIONS SUMMARY Unit for the study of alternators. Starting, operation and regulation of an alternator without load, half load and full load. The unit comprises: Base structure (painted steel and anodized aluminium). Couplings. Connectors. EMT7. Asyncrhonous Three-phase motor of squirrel cage: Power: 250-300W. Speed: 2769 r.p.m. (50Hz), 3330 r.p.m. (60Hz). Connections: Star/triangle. Frequency: 50/60 Hz. V.Armature:230/400V (50Hz), 250/440V. (60Hz). I.Armature nominal:1A-0.7A. EMT6. A. C. Syncrhonous alternator motor: Power: 250-300W. Speed: 3000 r.p.m. Frequency: 50Hz. Connections: Star/triangle. V.excitation nominal: 220V D.C. I.Excitation nominal: 0.59A. V.Armature.: 3x220/380V. VVCA/B. AC motors speed controller: This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a motor. Maximum power: 750 W. Frequency from 0 to 60Hz. Cables and accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 750 mm x 250 mm x 250mm approx. Weight: 30Kg. approx. PRACTICAL POSSIBILITIES 1.- Starting, voltage and frequency regulation in a three -phase alternator. 2.- Typical practices for a three-phase alternator. 3.- Characteristic curve of an alternator without load. 4.- Characteristic curve of an alternator in short circuit. 5.- Characteristic curve of an alternator with load. 6.- Synchronous motor starting. 7.- Working at a frequency given. 8.- Curves in V at constant power (1/4, 1/3, ½,1) PN and different power factors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/EEA.pdf Page 69 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY Teaching trainer for the simulation of non-destructive faults in three-phase motors. Application of diagnostic and localization. Unit and motor are mounted in a painted steel structure. Unit: Steel box. Electrical diagram of the motor on the front panel. The motor can be connected in star or delta connection. Connections for the measurements. The resistance of the windings can be measured. Pilot lamps. 6-position selector for the selection of the fault sequences. Switch for faults activation. Faults are implemented by means a PLC and internal relays. This lets the motor can keep on working in different conditions when certain faults are caused. 6 fuses of 2A to protect the motor. Automatic Magnetothermal Differential switch. Dahlander three-phase motor (0.3 to 0.5 CV), including cable and connector. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 800 mm x 400 mm x 400 mm approx. Weight: 30Kg. approx.