80 PLUS Verification and Testing Report
91.12%
89.71%
YES
TYPICAL EFFICIENCY (50% Load):
AVERAGE EFFICIENCY :
80 PLUS COMPLIANT:
3584.1
Leapfrog Distribution Pte Ltd
Armaggeddon Voltron Gold 400
NA
2013
ATX12V
5/30/13
Rated Specifications
Value
Units
Input Voltage
Input Current
Input Frequency
Rated Output Power
100-240
8-4
60-50
400
Volts
Amps
Hz
Watts
200
4
150
3
100
2
50
1
0
0
-50 0
0.003
PF
ITHD (%)
Load
(%)
Input
Watts
0.95
0.98
0.99
1.00
25.93%
18.43%
7.50%
5.32%
10%
20%
50%
100%
47.48
90.52
221.64
448.20
-3
-4
Time (s)
Voltage
Current
Input AC Current Waveform (ITHD = 7.5%, 50% Load)
DC Terminal Voltage (V)/ DC Load Current (A)
-12V
3.3V
12V (cumulative of 12V1, 12V2, etc.)
12.1/2.2
12.3/0
3.3/1.5
12.1/4.5
12.3/0
3.3/3
12.1/11.3
12.3/0.1 3.3/7.5
12/22.5
12.2/0.2 3.2/14.9
5V
5Vsb
5.1/1.4
5.1/2.7
5.1/6.8
5/13.6
5/0.2
5/0.4
5/1.1
4.9/2.2
Output
Watts
40.47
80.87
201.95
397.40
Efficiency
%
85.24%
89.34%
91.12%
88.67%
Efficiency of the Power Supply
450.00
90%
400.00
80%
Efficiency (%)
350.00
Power (Watts)
-1
-200
100%
Input Watts
250.00
200.00
150.00
Output Watts
70%
60%
50%
40%
30%
20%
50.00
10%
0.00
0%
20%
0.015
-2
Input and Output Power
100.00
0.012
-150
500.00
300.00
0.009
-100
Note: All measurements were taken with input voltage at 115 V nominal at 60 Hz.
IRMS
A
0.44
0.81
1.94
3.91
0.006
Current (A)
Input Current and Voltage Waveforms
Voltage (V)
Ecos ID #
Manufacturer
Model Number
Serial Number
Year
Type
Test Date
50%
100%
Loading (% of Rated Output Power)
Efficiency %
0%
25%
50%
75%
100%
Loading (% of Rated Output Power)
These tests were conducted by a third party independent testing firm on
behalf of the 80 PLUS Program. 80 PLUS is a certification program to
promote highly-efficient power supplies (greater than 80% efficiency in the
active mode) in technology applications. http://www.80plus.org/
125%