Installation technique Lighting time switch IL8811.41/100, SL8811.41/100 for fluorescent lamps with an electronic ballast unit 0222129 · VDE 0632 part 102 · Devices available in 2 enclosure versions: IL 8811: depth 58 mm, with terminals at the bottom for installation systems and industrial distribution systems according to DIN 43 880 SL 8811: depth 98 mm, with terminals at the top for cabinets with mounting plate and cable duct · For controlling a maximum of 20 fluorescent lamps with an electronic ballast unit · Control of bright and dimmed phase timing and operating time · Time setting for the bright phase · Reswitching of the bright phase possible · Variable degree of dimness · Remote control inputs for continuous light and dimmed light · With permanent light switch · Can be used in combination with Siemens dyn. electronic ballast unit 5LZ ... - 4 A; information about other lamps available on request · Width 35 mm Circuit diagrams A1 13 14 T A1 A2 A1 A2 T 13 + A2 T 14 13 - + Approvals and marking M7861 B2 M7860 B1 A1 13 14 T + - IL 8811.41/100, SL 8811.41/100 Applications 14 Staircase lighting time switch for controlling fluorescent lamps. Aim: to conserve energy. When the bright phase is over, the staircase is provided with dimmed light in accordance with DIN 18015 (draft). The life of the fluorescent lamp can be extended by using the electronic ballast unit. - Application examples: A2 + - IL 8811.41, SL 8811.41 Corridor lighting in old peoples homes During dinner time between 17.00 and 19.00 p.m. the corridor lights should be permanently switched on via a switch clock (contact B1). With switch 2 the light is dimmed between 19.00 and 20.00 p.m. while the local push button allows to activate bright light. At 22.00 p.m. the light goes off and can be switched on via the local buttons. Function diagram All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 IL 8811.41/100, SL 8811.41/100 / 21.11.01 bzd Applications Technical data Corridor lighting in hospitals During certain periods like lunch time, visiting time, shift change, doctor's round the light is switched on bright. During rest time, afternoon and night the light is dimmed. Using the locals push buttons the bright light can be activated individually. In the case of emergency a nurse can switch to bright light with switch B1 (no time limit). Weight IL 8811.41/100: SL 8811.41/100: Dimensions Width x height x depth IL 8811.41/100: SL 8811.41/100: Note The input (A1) and the pushbutton input (T) must be connected to the same phase (see connection example). Technical data Time range / bright phase: Repeat accuracy: Operating time: Degree of dimness: Nominal voltage UN: Control inputs B1, B2: Voltage range: Nominal consumption: + terminal: - terminal: Nominal frequency: Glow lamp load parallel to the pushbutton: 130 g 175 g 1 ... 10 min ± 2 % of the full scale value 30 min (fixed period) 90 ... 10 % AC 230 V AC 230 V (see Connection examples) 0,8 ... 1,1 UN 5,5 VA DC 10 V by electronic ballast unit DC 1 - 10 V from IL 8811 max. 20 electronic ballast units can be connected to the + - terminals 50 / 60 Hz 35 x 90 x 58 mm 35 x 90 x 98 mm Standard type IL 8811.41/100 AC 230 V 50/60 Hz · remote control inputs for continuous light and dimmed light · Output: 1 NO contact · Nominal voltage U N: AC 230 V · Width: 35 mm SL 8811.41/100 AC 230 V 50/60Hz · remote control inputs for continuous light and dimmed light · Output: 1 NO contact AC 230 V · Nominal voltage U N: · Width: 35 mm Connection examples + L N 10 mA Contacts IL 8811.41, SL 8811.41: Thermal current Ith: Switching capacity with fluorescent lamp load including electronic ballast unit: Electrical life AC 15 at 3 A, AC 230 V: Short circuit strength max. fuse rating: 1 NO contact, delayed 10 A B1 see connection diagrams EN 60 947-5-1 5 x 10 4 switching cycles 10 A gL A1 Housing: Vibration resistance: Climate resistance: Wire connection: Wire fixing: Mounting: A2 T + 14 1 2 EVG 3 4 M6974_b Connection example 1: One lamp: Max. 10 electronic ballast units with 16 / 32 W or 6 electronic ballast units with 58 W Two lamps: Max. 5 electronic ballast units with 16 / 32 W or 3 electronic ballast units with 58 W Continuous operation - 20 ... + 45°C 4 kV (air) 10 V/m 2 kV + L N 13 --------- only for IL8811.41/100 and SL8811.41/100 4 kV / 2 3 4 EN 60 947-5-1 General data Operating mode: Temperature range: Clearance and creepage distances overvoltage category/ contamination level: EMC Electrostatic discharge: HF irradiation: Fast transients: Surge voltages between wires for power supply: between wire and ground: Interference suppression: Degree of protection: B2 IL8811 SL8811 EVG ... Output 1 2 IEC 60 664-1 EN 61 000-4-2 EN 61 000-4-3 EN 61 000-4-4 2 kV EN 61 000-4-5 4 kV EN 61 000-4-5 Limit value class B EN 55 011 Housing: IP 40 EN 60 529 Terminals: IP 20 EN 60 529 Thermoplastic with V0 behaviour according to UL subject 94 Amplitude 0,35 mm EN 60 068-2-6 frequency 10 ... 55 Hz 20 / 045 / 04 EN 60 068-1 2 x 2,5 mm2 solid or 2 x 1,5 mm2 stranded ferruled DIN 46 228-1/-2/-3 Flat terminals with self-lifting clamping piece EN 60 999 DIN rail EN 50 022 2