* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Vigilon Interfaces
Survey
Document related concepts
Linear time-invariant theory wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Control theory wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Voltage regulator wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Buck converter wikipedia , lookup
Integrating ADC wikipedia , lookup
Flip-flop (electronics) wikipedia , lookup
Control system wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Transcript
Vigilon Interfaces The new range of Vigilon Interfaces from Gent meets all the interfacing requirements demanded by today’s fire detection and alarm applications. Each interface is supplied with a compact protective casing as well as a complete range of mounting options and housings to give maximum installation flexibility. A comprehensive range of loop powered interfaces covers a wide number of interfacing options with high and low voltage output and input units to monitor and control, plant and conventional zones. All units are compliant with EN54 parts 17 and 18. As with all Vigilon devices every Interface includes a short circuit isolator as standard. Single Channel Input Interface The single input Interface has a number of different configurations. Monitoring normally open or closed contacts the input can be set to initiate a fire, fault or supervisory event. The input can also manage a conventional zone of detectors and MCPs (up to 20 per zone). All remote cabling is monitored for short and open circuit. Single Channel Output Interface This unit has an output channel that can switch loads of up to 1A at 30V. A separate input can be configured to provide a confirmation input confirming a signal to critical equipment has been received. It can also be set to perform the same standard input function as the single input device (except for zone functionality). Alternatively it can be set to provide an output to drive LEDs rated at 1.5mA at 24V. This makes the unit ideal for controlling plant and indicating alarm status. Flexible Mounting Options for Vigilon Interfaces Low Voltage Range DIN rail Slide & lock Module Allen key Box Door Module M4 Screws Four Channel Input / Output Unit Metal backbox This flexible Four Channel device is housed in the same small enclosure as the Single Channel Interface. Channels can be configured independently as inputs or outputs each with the same performance as the single channel devices (conventional zones can only be connected to channel 1). Mains Output Interface DIN rail mount bracket Lid M4 Screws Mains Output Interfaces The Mains switching interface is designed to switch heavy-duty circuits (13A at 230V ac). This makes it ideal for managing plant in an emergency. Single Output Interface Module DIN Rail Mountable Single Output Interface with Case (Medium Voltage) in a Metal box Vigilon Interfaces Additional features l Analogue addressable communications. l Soft or SAFE addressing. l Built-in type identification automatically identifies these devices to the control panel. l Common mounting options surface mount, panel mount and DIN rail mount. l Reliable communication technique with high noise immunity. l Plug-in terminal connections for ease of field wiring. Single Input S4-34410 Four Channel I/O S4-34450 TECHNICAL SPECIFICATION type Single Input S4-34410 Low Voltage Input/Output Range Output Interface (Mains) Four Channel Input/Output (I/O) S4-34450 S4-34415 / S4-34411 Single Input/Output S4-34420 Approval EN54-17: 2005 and EN54-18: 2005 (Approval pending) Approvals Approx Weight 92g ➀ 100g ➀ 100g ➀ DIN mountable: 138g PCB with cover in metal box: 800g -10ºC to +60ºC Operating Temperature Up to 95% – Temperature 5ºC to 45°C (Non condensing) Relative Humidity Ingress Protection IP31 for plastic box S4-34490, IP40 estimated for metal box S4-34492 Metal box – IP40 estimated Device Load factor Load Factor 1-4 switch inputs = 1 (maximum 200 per loop) 1-4 relay outputs = 2 (maximum 200 per loop only 8 individually sectored) Zone Input = 26 (maximum 30 per loop) Every LED output = + 5 (maximum 100 LED outputs per loop) 5 (maximum 200 devices per loop) PANEL COMPATIBILITY Single Input/Output S4-34420 Compatible with Loop = V3.93 / V4.35 and Main Control Card = V3.94 / V4.37 Dimensions (mm) Plastic Box 245mm 23mm 90mm Gent by Honeywell Depth 77mm 14 0 W a t e r s i d e R o a d Hamilton Industrial Park 202mm Plastic Box S4-34490 Metal Box S4-34492 125mm 93mm 227mm Metal Box Depth 50mm Leicester Te l ( U K ) + 4 4 ( 0 ) 11 6 2 4 6 2 0 0 0 Te l (I n t ’ l ) + 4 4 ( 0 ) 11 6 2 4 6 2 2 0 0 Fax (UK) + 4 4 ( 0 ) 11 6 2 4 6 2 3 0 0 Fax (Int’l) + 4 4 ( 0 ) 11 6 2 4 6 2 2 1 0 L E5 1T N E-mail UK gentenquir y@honey well.com Website w w w.ge nt.co.uk Literature ref: GEN066