Vacuum Switch Pole mounted Vacuum switch for electricity distribution networks The vacuum switch reduces downtime, breaks and closes with full load. It reduces numbers of costumers affected by faults in the grid and increases the profitability in the network. VAI 150 is a pole mounted vacuum switch designed for use in overhead line distribution networks. The vacuum switch reduces downtime, breaks and closes with full load. It reduces the number of costumers affected by faults in the grid and increases the profitability in the network. Secure work can be performed during service, because of the visible open point and thanks to the integrated air break switch. MORE INTELLIGENCE AND FLEXIBLE COMMUNICATION By adding more intelligence, sectionalizing and flexible communication to the vacuum switch the opportunities for a more efficient handling of the interruptions in the net increases. Data and measurement of various values, such as phase current, voltage, power, frequency, earth fault, time stamp and history logging can be seen directly from the SCADA system. The vacuum switch acts quickly and cuts the power from the point where the vacuum switch is placed, this happens be- fore the substation even had time to react and cut, this means that fewer people are effected by the power cut. DESIGN The vacuum switches are cast in epoxy resin with a protective layer of silicone, which makes the poles very solid and protects the switches from bump and external impact of moisture and dust. The switches are equipped with robust cable connectors that ensures trouble-free life span and high service quality. Current is measured in two or three phases through current transformers and can be fitted with zero crossing CT to detect extremely low earth currents. INSTALLATION AND MAINTENANCE The vacuum switch is easy to install and is mainly made of stainless steel, it needs minimum of maintenance because of its surface that has good resistance against corrosion. • Breaks and closes with full load • Secure work with visible open point • Reduce downtime • Reduce numbers of costumers affected by faults • Increased profitability Solutions with Vacuum switch DIFFERENT SOLUTIONS VAI 150 - VACUUM SWITCH • Breaks and closes with full load • Reduce downtime • Reduce the number of affected costumers • Increased profitability • Maintenance-free and environmental friendly • Secure work with visible open point • Distinct indication for open/close • Indication for tension the spring ACR 150 - PROTECTION RELAY • Functions for measurements and controlling of current, voltage, power and frequency • Fault detection of phase and earth fault • Time stamp and log history • Automatic re-connection • Remote and local manoeuvring • Only a small part of the grid gets disconnected • Earth fault protection • Over current protection VIS 150 - REMOTE CONTROLLING • Manoeuvre up to three VAI 150 • Communicate with control system (SCADA) via PlexCom radio or other communication alternative • Self sectionalizing • Measure and calculate e.g. phase current, phase voltage, phase angle, phase power, reactive power, frequency and earth current with FRE 150 installed • Timestamp and log history S P E C I F I C AT I O N VA I 15 0 VOLTAGE/CURRENT Voltage: 12 kV (also available in 24 kV - VAI 160) Current: 630 A Short-circuit breaking current: 20 kA Max breaking current: 20 kA Max making current: 50 kA Max peak current: 50 kA Nominal resistance of power: 4 sec Isolation: 42/49 kV Nominal frequency: 50 Hz Operating sequence: 0-0.3s-CO-180s-C Short-circuit breaking current times: 30 times DIMENSIONS Vacuum switch + disconnector: H725 x L830 x W940 mm Weight: 180 kg ENVIRONMENTAL CLASSIFICATION Temperature: -40°C to +40°C Altitude: ≤ 1000 m Air pollution: class IV Intensity earthquake: ≤ degree 8 STANDARDS IEC 56: High voltage circuit breakers IEC62271-100: High voltage circuit breakers with control device (GB 1984) EXPERIENCE AREAS We have over 25 years of experience in digital radio communication in areas as VA-applications and network automation. Experienced employees and development in radio technology, automation and communication. Our units works as monitoring and control equipment in areas such as electricity distribution, oil & gas industry, water and wastewater, district heating, train systems, and in several other areas. Smart Grid Networks Sweden AB | Rombvägen 7 - SE-371 65 Lyckeby Sweden Operator +46 455 600 100 | [email protected] | www.smartgridnetworks.net PB-EN-2 © Smart Grid Networks Sweden AB Manoeuvres: 10 000 Rated operating voltage: 24 VDC Distance phases: 260 mm Contact resistance switch/with disconnector: ≤60/120 μΩ Manoeuvre: Switch - Manual/motor, Disconnector – Manual