Download to Specifications

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
TJ33IS5A Diesel Generator Sets / 50 Hz
50 Hz / 400 V Power Output Ratings Standby Power (ESP) Prime Power (PRP) kVA kW kVA kW 33 FOTON 26 30 24 Standby Power (ESP) Manufacturer Model No of Cylinder / Configuration Displacement Bore / Stroke Compression Ratio Aspiration Governor Type Cooling System Coolant Capacity Lubrication Oil Capacity Electrical System Speed / Frequency Engine Gross Power Fuel Consumption g/kWh
Exhaust Outlet Temperature Exhaust Gas Flow Combustion Air Flow Cooling Air Flow lt mm lt lt VDC kWm 110 % 100 % 75 % 50 % °C m³/min m³/min m³/min 4JB1T 4 ­ INLINE 2,771 93 / 102 18,2:1 Turbocharged MECHANIC WATER TBA Standby Power
Standby power is defined as the maximum power available during a variable electrical power
sequence, under the stated operating conditions, for which a generating set is capable of delivering in the
event of a utility power outage or under test conditions for up to 500 hours of operation per year under average of 70% load. Overloading is not permissible. 4,5 12 1500 rpm / 50 Hz 31 218 222,4 245 Prime Power
Prime power is defined as being the maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can
be overloaded 10% for 1 hour per 12 hours. 260 500 7,86 2,55 96 Alternator Manufacturer Model No of Phase Power Factor No of Bearing No of Poles No of Leads Voltage Regulation ( Steady State) Insulation Class Degree of Protection Excitation System Connection Type Total Harmonic Content (No Load) Frequency Voltage Output Rated Power (Standby) Efficiency Hz VAC kVA % MARELLI MJB160MB4 3 0,8 SINGLE 4 12 ± %1 H IP 23 AVR (Automatic Voltage Regulator), Brushless STAR < %2 50 230 / 400 35 88,3 W x L x H (mm) Canopied Open Skid 950 x 2200 x 1450 950 x 1650 x 1030 Weight (kg) 824 566 lt Fuel Tank (lt) Noise dB(A) @ 1m 90 70 90 TBA ­ Technical information and values are according to ISO8528, ISO3046,NEMA MG­1.22, IEC 60034­1, BS 4999­5000, VDE 0530 standards. ­ Producing with ISO9001, ISO14001, OHSAS18001, TSE, CE standards. ­ All information given in this leaflet is intended for general purposes only. Due to a policy continuous improvement Teksan reserves the right to amend details and specifications without notice and all information given is subject to the Teksan's current condition of sales. TBA: To Be Ask TBD: To Be Determined NA: Not Avaliable N/A: Not Applicable www.teksangenerator.com TTD33IS5A0414­EN 04.09.2014 11:02