Download LA125-P - RGB Automatyka

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ground loop (electricity) wikipedia , lookup

Transistor wikipedia , lookup

Electric machine wikipedia , lookup

Transformer wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Thermal runaway wikipedia , lookup

Skin effect wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Electric power system wikipedia , lookup

Power inverter wikipedia , lookup

Electrification wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Stepper motor wikipedia , lookup

Islanding wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electrical ballast wikipedia , lookup

Power engineering wikipedia , lookup

Electrical substation wikipedia , lookup

Ground (electricity) wikipedia , lookup

Current source wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

Distribution management system wikipedia , lookup

Rectifier wikipedia , lookup

History of electric power transmission wikipedia , lookup

Ohm's law wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Power MOSFET wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power electronics wikipedia , lookup

Stray voltage wikipedia , lookup

Buck converter wikipedia , lookup

Surge protector wikipedia , lookup

Earthing system wikipedia , lookup

Voltage optimisation wikipedia , lookup

Opto-isolator wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
DATASHEET
LEM
LA125-P
OTHER SYMBOLS:
RGB ELEKTRONIKA AGACIAK CIACIEK
SPÓŁKA JAWNA
Jana Dlugosza 2-6 Street
51-162 Wrocław
Poland
www.rgbelektronika.pl
[email protected]
+48 71 325 15 05
www.rgbautomatyka.pl
www.rgbautomatyka.pl
www.rgbelektronika.pl
YOUR
PARTNER IN
MAINTENANCE
Repair this product with RGB ELEKTRONIKA
LINEAR
ENCODERS
ORDER A DIAGNOSIS ∠
PLC
SYSTEMS
INDUSTRIAL
COMPUTERS
ENCODERS
CNC
CONTROLS
SERVO AMPLIFIERS
MOTORS
CNC
MACHINES
OUR SERVICES
SERVO
DRIVERS
POWER
SUPPLIERS
OPERATOR
PANELS
At our premises in Wrocław, we have a fully equipped servicing facility. Here we perform all the repair
works and test each later sold unit. Our trained employees, equipped with a wide variety of tools and
having several testing stands at their disposal, are a guarantee of the highest quality service.
Buy this product at RGB AUTOMATYKA
BUY ∠
Current Transducer LA 125-P
IPN
=
125 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
16030
Electrical data
IPN
IPM
RM
Primary nominal current rms
Primary current, measuring range
Measuring resistance @
with ± 12 V
with ± 15 V
ISN
KN
VC
IC
125
0 .. ± 200
TA = 70°C
TA = 85°C
RM mini RM maxi RM mini RM maxi
@ ± 125 A maxi
@ ± 200 A maxi
@ ± 125 A maxi
@ ± 200 A maxi
5
5
25
25
Secondary nominal current rms
Conversion ratio
Supply voltage (± 5 %)
Current consumption
52
20
74
34
14
14
40
40 1)
50
18
72
40 1)
A
A
ε
Accuracy @ IPN , TA = 25°C
Ω
Ω
Ω
Ω
125
mA
1 : 1000
± 12 .. 15
V
16 (@ ± 15 V) + IS mA
@ ± 15 V (± 5 %)
@ ± 12 .. 15 V (± 5 %)
Linearity error
L
± 0.60
± 0.80
< 0.15
Typ
IO
IOM
IOT
tra
tr
di/dt
BW
%
%
%
Maxi
± 0.40
Offset current @ IP = 0, TA = 25°C
Magnetic offset current 2) @ IP = 0 and specified R M,
after an overload of 3 x IPN
Temperature variation of IO
0°C .. + 70°C
- 40°C .. + 85°C
± 0.50
± 0.15 ± 0.50
± 0.30 ± 0.95
Reaction time @ 10 % of IPN
Response time 3) 4) to 90 % of IPN step
di/dt accurately followed 4)
Frequency bandwidth 4) (- 1 dB)
< 500
<1
> 200
DC .. 100
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @
m
Mass
Standards
2)
3)
4)
according to UL 94-V0.
Advantages
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
• Current overload capability.
Applications
mA
mA
mA
ns
µs
A/µs
kHz
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
TA
TS
RS
1)
• Printed circuit board mounting
• Isolated plastic case recognized
mA
General data
Notes:
• Closed loop (compensated) current
transducer using the Hall effect
Accuracy - Dynamic performance data
X
Features
TA = 70°C
TA = 85°C
- 40 .. + 85
°C
- 40 .. + 90
°C
32
Ω
33.5
Ω
40
g
EN 50178: 1997
• Power supplies for welding
applications.
Application Domain
• Industrial.
Measuring range limited to ± 180 A maxi
The result of the coercive field of the magnetic circuit.
With a di/dt of 100 A/µs
The primary conductor is best filling the through-hole and/or the return
of the primary conductor is above the top of the transducer.
page 1/3
070806/12
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Current Transducer LA 125-P
Isolation characteristics
Vd
Vw
Rms voltage for AC isolation test, 50/60 Hz, 1 min
Impulse withstand voltage 1.2/50 µs
3
7
kV
kV
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative Tracking Index (Group IIIa)
Mini
6.7
6.7
175
mm
mm
Application examples
According to EN 50178 and IEC 61010-1 standards and following conditions:
• Over voltage category OV 3
• Pollution degree PD2
• Non-uniform field
EN 50178
IEC 61010-1
Rated isolation voltage
Nominal voltage
Single isolation
600 V
600 V
Reinforced isolation
300 V
300 V
dCp, dCI, V W
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the manufacturer's
operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
page 2/3
070806/12
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Dimensions LA 125-P
(in mm. 1 mm = 0.0394 inch)
Bottom view
Left view
Connection
Front view
Mechanical characteristics
Remarks
• General tolerance
± 0.2 mm
• Primary through-hole
17 x 11 mm
• Fastening & connection of secondary 4 pins 0.63 x 0.56 mm
• IS is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
Recommended PCB hole
• Supplementary fastening
Recommended PCB hole
Recommended screws
Recommended fastening torque
0.9 mm
2 holes ∅ 1.75 mm
2.4 mm
PT K A 22 x 6
0.5 Nm or .37 Lb. - Ft.
90°C.
• Dynamic performances (di/dt and response time) are best
with a primary bar in low position in the through-hole.
• In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
• This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
page 3/3
070806/12
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com