Download Reference in English

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
Reference conditions for photo taking of 20 items in kb3
1.mi-ma-mo(Focus on the finger-rest contact points in
the mouth)
①y dimension: Set the camera at the midsagittal plane of
a patient or a sim head.
②Use a stick like a sliding aerial to decide the direction
of the camera that covers the finger-rest contact points
(mi-ma-mo).
③Set the camera to the direction of the aerial.
④Take the aerial away and click the shutter.
➄ Include the end of the instrument held by the right hand
in the shooting range
⑥ Make sure that the directions of the mirror surface
and the handle in the left hand is clearly seen.
2. Photo of the side view of an operator’s upper body
① z dimension - Set the camera at the height of the
operator’s shoulder.
② x dimension – Set the camera parallel to the
midsagittal plane of the patient.
③ z dimension – Range from the top of the head to
the thigh.
④ y dimension – Range from the back of the operator
to the chest of the patient.
te1 me explorer
ta00
ma16 mo336682(33=facial surface, 66=distal-lingual line angle, 82=apical point)
te2 me explorer
ta00
ma36 mo365362(36=distal surface, 53=facial aspect, 62=gingival border)
te3 me impression tray
ta03
ma01 mo4162(41=apical alveolar aspect, 62=apical border
te4 me impression tray
ta03
ma02 mo4162(41=apical alveolar aspect, 62=apical border)
te5 me periapical x-ray film
ta06
ma16 mo33(33=facial surface, x=mesial-distal, z=occlusal-apical locations)
te6 me chart and aids (x-rays)
ta10
ma00 (treatment plan presentation, informed consent, full body relations)
te7 me band pusher
ta37
ma36 mo3365(33=facial surface, 66=distal border)
This orthodontic band pusher will be replaced by a newly designed one.
te8 me root scraper
ta44
ma17 mo19365382(19=unwanted substance, 36=distal surface, 53=facial aspect,
82-gingival point)
te9 me root scraper
ta44
ma36 mo19365462(19=unwanted substance, 36=distal surface, 54=lingual aspect,
62=gingival border)
te10 me handpiece
ta54
ma22 mo19344881(19=unwanted substance, 34=lingual surface,
48=cingulum-occlusal aspect, 81=occlusal point)
te11 me handpiece
ta57
ma17 mo364864(36=distal surface, 48=middle 3rd crown, 64=lingual line)
te12 me handpiece
ta57
ma46 mo364864(36=distal surface, 48=middle 3rd of crown, 64=lingual line)
te13 me endodontic file
ta66
ma16 mo05113291(05=pulp space, 1132=root, 91=mesial-facial)
?
te14 me endodontic file
ta66
ma36 mo05113291(05=pulp space, 1132=root, 91=mesial facial)
?
te15 me root tip remover
ta74
ma14 mo0681(06=periodontal ligament, 81=occlusal end)
te16 me extraction forceps
ta75
ma16 mo063163,64(06=periodontal ligament, 31=occlusal, 63,64=facial and
lingual lines)
te17 me extraction forceps
ta75
ma36 mo063163,64(06=periodontal ligament, 31=occlusal, 63,64= facial and
lingual lines)
te18 me anesthetic needle
ta77
ma17 mo33416285(33=facial surface, 62=alveolar border, 85=mesial point)
te19 me anesthetic needle
ta77
ma30 mo86z、x mm(86=distal end, z=occlussal-apical, x=mesial-distal location (mm)
from mo86)
Note: ta77ma40 inject with left fingers at mi1±0?
te20 me sim/clinical material
ma9363
ma00 mo31(31=occlusal surface)
Note: This material is isocompound (GC company).
Related documents