3. TOWER VERSION UPS INSTALLATION 5 - MUTE function indicator Canceling messages Press the button to cancel the currently displayed message. Icon indicating the activation / deactivation of sound signal when the UPS is in back-up (battery) mode. The UPS alarm states is not muted. Increasing the value of parameters Press the button to increase the value of the edited parameter. 6 – GREEN function indicator Press the button shortly to scroll down between information screens. UPS SINLINE RT Icon activating / deactivating the function of saving energy stored in the batteries. When the UPS is in back-up (battery) mode and there are no receivers connected or power consumption is below the threshold value of 30 W, the UPS will automatically switch off after 15 minutes. Scrolling down QUICK REFERENCE GUIDE Press the button shortly to navigate down the menu options. x2 x2 7 – UPS operation indicator Note: to obtain detailed information, please read the full instruction manual, which can be downloaded from our website www.ever.eu. C Switching the sound alarm on/off Press and keep the button depressed for over 1 second to switch the UPS unit's sound alarm on/off. The function is only accessible from information screens. The icon is displayed if one of the following operation modes is activated: EMERGENCY, STOP or READY. Navigating to the end of the submenu Press and keep the button depressed for over 1 second to navigate to the end of the submenu. The UPS is on logically, the mains parameters are correct. After the UPS switches from the STANDBY mode, the unit waits until the battery is charged to a minimal, required level declared in % (CONFIGURATION; UPS; STB - ChargeMin). Decreasing the value of parameters Press the button shortly to decrease the value of the edited parameter. Confirming messages Press the button shortly to confirm the currently displayed message. 1. IN THE PACKAGING The UPS operates in STANDBY mode. The mains voltage fails to satisfy the correctness criteria, the UPS is on logically. The UPS operates in back-up (battery) mode - there is no mains power supply or threshold frequency value or effective value of supply voltage are exceeded. Quick reference guide b. Rear panel: 2 sets of Tower supports for installing the unit vertically 1 The UPS operates in mains (normal) mode. 2 3 4 5 6 7 The UPS operates in INIT (initialization) mode. 1. Output sockets PN-E-93201 (10 A) 2. Output sockets IEC 320 C13 (10 A) 3. Automatic fuse 4. Mains input: IEC 320 C14 (10 A) SINLINE RT 1000 – 1200 IEC 320 C20 (16 A) SINLINE RT 1600 – 3000 5. Fan 6. Ethernet communication port 7. USB communication port UPS unit 4. ELEMENTS OF THE UPS 1 a. Front panel: SINLINE RT 1000 | 1200 1 2 Warranty card *Depending on the UPS unit Power cord CEE 7/7 - IEC 320 C13 (10 A) lub CEE 7/7 - IEC 320 C19 (16 A)* 3 USB cable 2 3 4 5 6 Button Function Low battery charge level. The icon is displayed in case of an overload of the UPS. Battery is used up and must be replaced. In order to replace the battery and to deactivate the icon, please contact EVER Support Centre. Description 5. DESCRIPTION OF LCD DISPLAY ICONS 1 Switching on Switching off >10cm Press and keep the button depressed for over 1 second to switch the unit on (power supply is switched on). 5 The icon is displayed if the permissible temperature of the battery or inverter is exceeded. 2 6 7 3 4 8 9 There are no messages or they are not shown in graphical form (but are available from the Messages screen). When the UPS is on and the LCD display shows one of the information screens (screensavers), press and keep the button depressed for over 1 second to switch the unit off (power supply is switched off). 9 – Alarms If the icon is activated, the UPS unit's output is overloaded or shorted, or there is reversed voltage. The detailed description is available from the Alarms screen. A Access to main menu max. 1,8m Confirming / canceling the current setting SINLINE RT 1200 AVR system activity signalization (decreasing value). SINLINE RT 1600 | 2000 | 3000 Functions of the control panel buttons >10cm AVR system activity signalization (increasing value). C B A 2. ADDITIONAL REMARKS SINLINE RT 1000 7 1. Signaling LED 2. LCD display 3. Multi-function buttons: A, B, C 8 – Messages SINLINE RT 1600 SINLINE RT 2000 SINLINE RT 3000 Switching the unit on logically Switching the unit off logically When an information screen is displayed, press the button shortly to enter the main menu. When in MENU screen, press the button briefly to select or change the highlighted option (depending on what option is selected, the button's action is indicated by an icon shown on the LCD display, next to the button). When the value edit mode is selected, press the button briefly to change the active object (edited values or command keys). When in command selection mode, keep the button depressed to execute the operation assigned to the object. When the UPS is not on logically (not operating in back-up or normal mode), and the LCD display shows one of the information screens, press and keep the button depressed for over 1 second to switch the unit on logically (power supply to receiver's connected to the UPS's output is switched on). When the UPS is on logically (operating in back-up or normal mode), and the LCD display shows one of the information screens, press and keep the button depressed for over 1 second to switch the unit off logically (power supply to receiver's connected to the UPS's output is switched off). Symbol The icon is displayed in case of: internal error, EPO triggering or if the permissible temperature of the battery or inverter is exceeded. The detailed description is available from the Alarms screen. If there is an internal error, please contact the service department. Description 1 – UPS output load indicator Load level signaling. Further segments of the icon light up while the load increases. No alarms. 2 – LAN connection indicator Signal confirming that the UPS is connected to LAN and visualization of the direction of transferred data. Packets sent to the network (icon received from the network (icon ), packets ) 3 - USB connection indicator The icon is displayed if the UPS is connected with the PC through USB. B Press the button shortly to scroll up between information screens. Scrolling up 4 - Battery charge level indicator Press the button shortly to navigate up the menu options. +5 ÷ +35 °C Battery charge level indicator. Further segments of the icon light up SINLINE RT battery back-ups are not designed to power medical equipment, in particular life support machines! Type 01 Navigating to the beginning of the submenu Press and keep the button depressed for over 1 as the battery charge level increases. second to navigate to the beginning of the submenu. v3 20150917 6. BATTERY BACK-UP CONNECTION 8. CONTACT Ethernet USB EVER Sp. z o.o. IEC32 0 230V [email protected] www.ever.eu 7. FIRST START >1s DOWNLOAD WWW.EVER.EU 230V SOFTWARE 4h 230V 230V ON ON Type 01 v3 20150917