Download 4 Status Relay Output

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Audio power wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Power inverter wikipedia , lookup

Switch wikipedia , lookup

Transmission line loudspeaker wikipedia , lookup

Alternating current wikipedia , lookup

Current source wikipedia , lookup

Islanding wikipedia , lookup

Power engineering wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Electrification wikipedia , lookup

Three-phase electric power wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power electronics wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Protective relay wikipedia , lookup

Relay wikipedia , lookup

Transcript
Ultrasonics
Application Note 104
• Relay contact outputs are not attached to ground and can switch up to 28Vdc @ 2A
• Relay contact outputs can also switch resistive ac loads up to 120Vac @ 1A
• Single Pole Double Throw (SPDT) contacts offer normally open or normally closed
options
• Output state is jumper programmable with one of four selections on SH402 on
driver board
• Relay contacts are fused at 2 Amps to protect the internal generator circuitry
The Status Relay Output is a circuit board mounted inside the generator that provides a SPDT
relay contact output on the rear panel connector labeled J23 Status Relay. This output is useful
when a floating (non-grounded) mechanical switch is needed. The user must provide a load
to be switched and the load’s power source. The power source can be ac or dc within the
voltage switching capabilities of the internal relay. The load current must also be within the
relay switching capacity. A 2 Amp fuse is installed on the circuit board to protect the internal
generator circuitry, but the relay contacts may fail if it is connected to dc sources greater than
28Vdc, non-resistive ac loads, or ac loads exceeding 1 Amp.
The status relay contacts are controlled by the status driver output on the generator driver
board (Dukane Part #110-2586 or #110-2611). Using selections available on jumper block
SH402, the user can select one jumper for either ultrasound output status or overload fault
status. Jumper JU404 is installed at the factory. The jumper options available are as follows:
HEADER SH402 USER SELECTABLE JUMPER BLOCK OPTIONS
JUMPER BLOCK NOT INSTALLED ON SH402 - STATUS OUTPUT DISABLED
JU402 - RELAY COIL IS NORMALLY OFF - ACTIVATES WHEN ULTRASOUND IS ACTIVE
JU403 - RELAY COIL IS NORMALLY ON - DEACTIVATES WHEN ULTRASOUND IS ACTIVE
© Copyright 1998 Dukane Corporation. All rights reserved.
Application Notes
Model 110-2837 Status Relay Output
JU404 - RELAY COIL IS NORMALLY OFF - ACTIVATES IF AN OVERLOAD FAULT OCCURS
JU405 - RELAY COIL IS NORMALLY ON - DEACTIVATES IF AN OVERLOAD FAULT OCCURS
Note: It is recommended to select a jumper option that keeps the relay coil OFF for a majority of the time.
Only one jumper should be installed on SH402. Internal circuit damage will result if more
than one status jumper is installed.
Dukane Ultrasonics • 2900 Dukane Drive • St. Charles, Illinois 60174 USA
TEL (630) 584-2300 • FAX (630) 584-3162
www.dukane.com • [email protected]
A N 1 04
Application Note 104
The user must connect an external power source (ac or dc) and an appropriate load to the
J23 Status Relay connector on the generator rear panel. The power source common (or
negative) should be connected to one side of the load (negative side if the load is polarity
sensitive). The other side of the power source, hot (or positive), should connect to J23 pin
1 (relay common). The other side of the load (+ side) is connected to J23 pins 2 or 4, depending
on whether the load is supposed to be normally OFF or normally ON. If jumpers JU402 or
JU404 are installed on SH402, connecting the load (+ side) to J23 pin 2 will result in the load
being normally OFF. If jumpers JU403 or JU405 are installed on SH402, connecting the load
(+ side) to J23 pin 4 will also result in the load being normally OFF. For the load to be normally
ON, connect the load (+ side) to the opposite J23 pin number (i.e., pin 4 instead of pin 2, or
pin 2 instead of pin 4) that is described above. Refer to the connection diagram on the
following page for further details on how to correctly connect the external power source and
load.
(next page)
© Copyright 1998 Dukane Corporation. All rights reserved.
Application Notes
Ultrasonics
Dukane Ultrasonics •␣ 2900 Dukane Drive • St. Charles, Illinois 60174 USA
TEL (630) 584-2300 • FAX (630) 584-3162
www.dukane.com • [email protected]
2
Application Note 104
Status Relay Connection Diagram
Generator Internal Circuitry
+24V
Red
Driver Board PCB Assembly
110-2586 or 110-2611
JU402
JU403
JU404
JU405
Application Notes
Ultrasonics
F402
1.0 Amp
Status Relay PCB
Assembly 110-2837
1
Wht / Vio
Wht / Vio
3
Power
Source
J23
F601
2.0 Amps
1
K601
Red
2
2
P401
Pin 8
Q204
User Supplied
Items
Com.
(–)
Load
(+)
Blk
Normally Open Contact
3
Coil
ac
or
dc
Hot
(+)
Polarization Pin
4
Wht
Normally Closed Contact
Note: Connect the load to
either J23 pin 2 or pin 4, not
both.
4
P601
SG402
30 Vdc max
SH402
Blk
J20
P401
Pin 9
Status Driver Output
Note: Jumper JU404 is installed at the factory
Chassis Ground
Status Relay Cable
200-999 Wire Colors
Pin #1 = Red Wire
Pin #2 = Black Wire
Pin #3 = Polarization Pin
Pin #4 = White Wire
© Copyright 1998 Dukane Corporation. All rights reserved.
= Relay Common
= Normally Open Contact
= No Connection
= Normally Closed Contact
Wht / Vio
Status
Driver
Output
5
Blk 13
J23 Status Relay
Output
1
3
2
4
Connector Pin Locations
on Generator Rear Panel
3