* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Wind converter
Survey
Document related concepts
Alternating current wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electrification wikipedia , lookup
Mains electricity wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power engineering wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power electronics wikipedia , lookup
Distributed generation wikipedia , lookup
Buck converter wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Transcript
Wind converter © Siemens AG 2012. All Rights Reserved. Application Wind converters adapt the changing speed continually to the fluctuating wind velocity therefore achieving the optimum efficiency. They decouple the power generation and therefore the complete mechanical system from the line frequency. As a consequence, in the case of a fault, the mechanical components are completely protected against the torque surges. September 2012 © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 Customer requirements Can handle typical control modes related to wind turbine operation Complies with the requirements regarding electrical grid compatibility, which are becoming increasingly more stringent (grid codes) Maximum reliability Simple integration and installation September 2012 © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 Overview of the converter portfolio for wind turbine systems Wind converters Two wind converter concepts available Focus on onshore wind turbines, with power ratings up to 5…6 MW: Low-voltage platform based on DYNAVERT XL technology Focus on offshore wind turbines, with power ratings above 5…6 MW: Medium-voltage platform based on SINAMICS technology September 2012 © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 Converter technology – an overview Wind converter types Double-fed induction generator (DFIG) Partial converter September 2012 Induction generator Direct drive Synchronous generator Full converter © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 Low-voltage platform based on DYNAVERT XL technology Existing product range 800 kW SM (special design) September 2012 1.5…2 MW partial converter New! 5.5 MW full converter 1…8 MW full converter © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 Low-voltage platform based on DYNAVERT XL technology Benefits Complete converter system with filter and circuit-breaker in one compact unit Air or water cooling State-of-the-art remote maintenance and remote diagnostics software Can be flexibly adapted to the wind turbine characteristics Control voltage can be supplied from the DC link With plenty of features like automatic encoder calibration etc. Power range Due to a modular design in Software and Hardware Dynavert XL is adaptable to nearly every request. This portfolio overview represents only the common product line / market level. September 2012 ! © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 Low-voltage platform based on DYNAVERT XL technology Key features modular design redundant Power Units easy to maintain – all spare parts are accessible with integrated Braking-chopper and resistor with all filter elements with all switching and safety equipment simply removable with quick fasteners and press-lock PU-module provides all relevant parts pollution level 3 max. spare-part weight: 25kg September 2012 Size comparison Up to seven power units in parallel for an adaptation to every turbine. © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 non non Medium-voltage platform based on SINAMICS technology 9 8 7 6 5 4 3 2 1 0 -1 10 8 0 6 4 2 0 -2 -4 -6 -8 -10 0 ^ V L1M VZ1 Vd/2 VZ2 30 60 90 120 150 180 210 240 270 300 330 360 210 240 270 300 330 360 t [°] VL1M VL12 30 60 90 120 150 180 t [°] Power range (water-cooled): Voltage range: 3.0MW – 12.0MW 3kV – 6.6kV New multi-level technology High-level output voltage characteristic Sine-wave filter not required September 2012 © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 Customer advantages LOHER Dynavert XL wind converters can handle all of the control modes typical for wind turbines Matching wind turbine systems with double-fed induction generators, induction generators, synchronous generators as well as permanent-magnet generators Tailored solutions to address individual wind turbines Both for onshore as well as offshore applications Simple integration All of the generally used interfaces are provided Low space requirement: as a result of an unbeatable power density Complete: converter system including filter and circuit breaker in one device Highest reliability: 100% quality check before being shipped Fast “time to market” through simple engineering Highest flexibility in the engineering, modular design for simple engineering according to specifications as well as easy scalability to 8 MW User-friendly Inverter Management System (IMS): parameterizing, operating and monitoring State-of-the-art remote maintenance and diagnostic software Aligned to address future requirements: All of the actual grid requirements are fully complied with September 2012 © Siemens AG 2012. All Rights Reserved. Industry Sector – HUSUM 2012 Thank you for your attention! © Siemens AG 2012. All Rights Reserved.