V
REMOTE INTERFACES
Technix offers 3 different Remote Interfaces:
-
With Standard Remote Interface the ground of the external control signals
(0 Volt reference) is the same as Power Supply ground.
With Insulated Remote Interface, 0 V reference of External Control is insulated
from Chassis ground up to 500 V.
With Optical Fiber, Isolated Remote Interface, 0 V reference of External
Control is completely insulated from Chassis Ground.
1) Standard Remote Interface
This is the standard Remote Interface we offer with our machine.
External Control ground (0 V reference) is the same as Power Supply ground.
High Voltage
Output
Generator
Standard
Remote
Interface
External
Control
CHASSIS
There is no insulation between Power Supply and External Control
Technix, 6-8 Rue Eugène Dupuis 94000 Créteil - France - Tel: +33.(0)1.56.71.28.60 - Fax: +33.(0)1.56.71.28.69
1/3 Remote Interfaces 091116
2) Insulated Remote Interface:
With this option, 0 V reference of External Control is insulated from chassis ground up
to 500 VDC.
High Voltage
Output
Generator
Isolated
Remote
Interface
CHASSIS
Galvanic
insulation
External
Control
0 Volt
Insulation between Power Supply and External control up to 500 Volts DC
Remark : Pin out of the connector of Insulated Remote Interface is the same as
the pin out of the connector of Standard Remote Interface without
10 V Reference (pin 14)
Reference of this option : ISOREMOTE
Technix, 6-8 Rue Eugène Dupuis 94000 Créteil - France - Tel: +33.(0)1.56.71.28.60 - Fax: +33.(0)1.56.71.28.69
2/3 Remote Interfaces 091116
3) Remote Interface insulated with optical fiber
With this option, 0 V reference of External Control is completely insulated from
Chassis Ground ( insulation
> 100 kV/meter of fiber).
High Voltage
Output
Generator
Optical Fiber kit
RS232 interface
CHASSIS
External
Control
0 Volt
Complete Insulation between Power Supply and its External control
Reference of this option : FIBER OPTICS
Optical fiber kit consists in is 2 Transmitter/Receiver and 25 m optical cable.
It has to be used in conjunction with RS232 interface (option : RS232).