Download High Frequency 1,000 Hz High Frequency 1,000 Hz (at 0.2 MPa)

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Blood pressure wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Heterodyne wikipedia , lookup

Delta-sigma modulation wikipedia , lookup

Transcript
High Frequency 1,000
Hz
(at 0.2 MPa)
2 Port Solenoid Valve
Maximum valve-turnover
frequency:
1,000 Hz
0.9 ±0.15 ms
(Supply pressure at 0.2 MPa)
ON response time (msec)
Response time/ON response:
1
0.95
0.9
0.85
0.8
0
0.1
Service life:
0.2
0.3
Supply pressure (MPa)
0.4
0.5
1
billion times
or more
m
m
1
1
th:
Wid
Faster selection of work pieces
Weight:
26 g
(not including sub-plate)
NPP-E06-13
Series VQJ01
Manifold available as a standard feature
(Up to 32 stations)
Please consult SMC for more than 32 stations.
Flow rate: 120
(Normally open, Supply pressure at 0.4 MPa)
C[dm3/(S·bar)]
0.4
b
0.28
Cv
0.11
C4 fittings
Flow
characteristics
l
C[dm3/(S·bar)]
0.4
b
0.37
Cv
0.11
C6 fittings
With one-touch fittings
Possible to change the fitting sizes.
Specifications
Type of port connection
For manifold (without sub-plate)
Construction
One-touch fitting
ø4, ø6
One-touch fittings (ø4/ø6)
Direct operated 2 port/Metal (Stainless steel) poppet seal
Action
N.C.
Min. operating pressure
0.2
Max. operating pressure
0.4
Rated voltage
24 VDC, 48 VDC
Valve leakage
1,500 cm3/min or less
Ambient and fluid
temperature
0 to 40°C
Enclosure
IP40
Mounting orientation
Free
Recommended Voltage Waveform
∗ The input voltage waveform is
subject to operating frequency.
Rated coil
Waveform
One-touch fitting
ø4, ø6
M5 x 0.8
0V
ON
Rated coil
24 VDC Note 1)
48 VDC
Operating frequency ON
500 Hz or less
OFF
501 to 1,000 Hz
OFF
0.7 to 0.8 msec
0.9 to 1 msec
1.2 msec or more
1.1 msec or more
ON
0.6 msec
0.7 msec
OFF
0.4 msec or more
0.3 msec or more
Note 1) Do not exceed 30 seconds of continuous use when using products with 24 VDC and an operating
frequency of 400 Hz or more. After using products continuously, the de-energizing time must be longer
than the energizing time.
Input signal waveform
····
Continuous use
(400 Hz or more)
30 seconds or less
····
OFF
More than the time of continuous use
Akihabara UDX 15F,
4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
URL http://www.smcworld.com
© 2007 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
D-KS
1st printing LY printing LY 11350KS Printed in Japan.
This catalog is printed on recycled paper with concern for the global environment.