Download Compare Syringe Pumps

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
Compare Syringe Pumps
Can?t decide which high-precision syringe pump to add to your lab? Use this chart to compare
features. For more help determining the best fit for your research application, or if you?re ready to
order, contact a Customer Care representative.
1-281-277-5499
[email protected]
Fusion 100
Fusion 200
NanoJet
1,300 USD
1,520 USD
1,520 USD
Movement Mode: Infuse Only
Movement Mode:
Infuse/Withdraw
Movement Mode:
Infuse/Withdraw
Min. Flow Rate: 100 pL/min (with
0.5 ?L syringe)
Min. Flow Rate: 100 pL/min
minimum flow (with 0.5 ?L
syringe)
Min. Flow Rate: 1 nL/min (with
0.5 ?L syringe)
Max. Flow Rate: 128 mL/min
(with 60 mL syringe)
Max. Flow Rate: 128 mL/min
maximum flow (with 60 mL
syringe)
Max. Flow Rate: 1 mL/min (with
1 mL syringe)
Linear Force: 9.1 kg (20 lb)
Linear Force: 16 kg (35 lb)
Linear Force: 4.5 kg (10 lb)
Max. Syringe Volume: 60 mL
Max. Syringe Volume: 60 mL
Max. Syringe Volume: 1 mL
Step Resolution: 0.098 microns
Step Resolution: 0.046 micron
Step Resolution: 0.298 microns
www.chemyx.com | 10905 Cash Rd., Stafford, TX 77477 | 1-281-277-5499 | [email protected]
Height: 11 cm (4.4 in.)
Height: 12 cm (4.7 in.)
Height: 10 cm (4 in.) control box,
5.6 cm (2.2 in.) header
www.chemyx.com | 10905 Cash Rd., Stafford, TX 77477 | 1-281-277-5499 | [email protected]
Fusion 100
Fusion 200
NanoJet
Length: 24 cm (9.5 in.)
Length: 24 cm (9.5 in.)
Length: 24 cm (9.5 in.) control
box, 22 cm (8.8 in.) with header
Depth: 17 cm (6.8 in.)
Depth: 17 cm (6.8 in.)
Depth: 14 cm (5.6 in.) control
box, 5.8 cm (2.3 in.) header
Weight: 3 kg (7 lb)
Weight: 3 kg (7 lb)
Weight: 2 kg (5 lb) control box,
0.5 kg (1.2 lb) header
Screen: 10.8 cm (4.25 in.)
diagonal
Screen: 10.8 cm (4.25 in.)
diagonal
Screen: 9.9 cm (3.9 in.) diagonal
Ports: RS232 (DB9 or USB-B) and
TTL (USB-B Pin 2 and 4) COM
Ports
Ports: RS232 (DB9 or USB-B) and
TTL (USB-B) COM Ports
Ports: RS232 (DB9) COM Port
Power: 110/220 VAC
Power: 110/220 VAC
Power: 110/220 VAC
Operation Temp.: 4°C to 40°C
(40°F to 104°F)
Operation Temp.: 4°C to 40°C
(40°F to 104°F)
Storage Temp.: -10°C to 70°C
(14°F to 158°F)
Storage Temp.: -10°C to 70°C
(14°F to 158°F)
Storage Temp.: -10°C to 70°C
(14°F to 158°F)
Humidity: 20% to 80% RH, noncondensing
Humidity: 20% to 80% RH, noncondensing
Humidity: 20% to 80% RH, noncondensing
Compliance: CE, RoHS, REACH,
FCC, IC
Compliance: CE, RoHS, REACH,
FCC, IC
Compliance: CE, RoHS, REACH,
FCC, IC
Computer Control:Windows: XP,
VISTA, 7, 10Mac: Mac OS X v10
or laterMost Linux
distributionsMATLAB and
LabVIEW controller programs;
Python coming soon
Computer Control:Windows: XP,
VISTA, 7, 10Mac: Mac OS X v10
or laterMost Linux
distributionsMATLAB and
LabVIEW controller programs;
Python coming soon
Computer Control:Windows: XP,
VISTA, 7, 10Mac: Mac OS X v10
or laterMost Linux
distributionsMATLAB and
LabVIEW controller programs;
Python coming soon
Accuracy: ± < 0.04% error
Accuracy: ± < 0.04% error
Accuracy: ± < 0.04% error
www.chemyx.com | 10905 Cash Rd., Stafford, TX 77477 | 1-281-277-5499 | [email protected]
www.chemyx.com | 10905 Cash Rd., Stafford, TX 77477 | 1-281-277-5499 | [email protected]
Reproducibility: ± < 0.05%
deviation
Reproducibility: ± < 0.05%
deviation
Reproducibility: ± < 0.05%
deviation
Purchase Includes: syringe
pump, power cable
Purchase Includes: syringe
pump, power cable
Purchase Includes: syringe
pump, power cable, one syringe
header
Available Accessories: , ,
Available Accessories: , , ,
Available Accessories:, , ,
www.chemyx.com | 10905 Cash Rd., Stafford, TX 77477 | 1-281-277-5499 | [email protected]