Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
MARATHON ELECTRIC GENERATORS TYPICAL SUBMITTAL DATA MODEL : 433RSL4021 Winding H-SG430039 BASE MODEL: 433RSL4021 Submittal Data: 480 Volts*, 404.8 kW, 506 kVA, 0.8 P.F., 1800 RPM, 60 Hz, 3 Phase Kilowatt ratings at 1800 RPM 60 Hertz kW (kVA) 3 Phase 0.8 Power Factor Class F Class B 105º C British Standard Voltage* 330 (413) 350 (438) 365 (456) 380 (475) 480/240 325 (406) 345 (431) 355 (444) 370 (463) 460/230 315 (394) 335 (419) 345 (431) 360 (450) 440/220 315 (394) 320 (400) 330 (413) 355 (444) 416/208 280 (350) 295 (369) 315 (394) 315 (394) 380/190 Rise by resistance method, Mil-Std-705, Method 680.1b. 80º C Continuous 90º C Lloyds 95º C ABS 12 LEADS 105º C Continuous 380 (475) 370 (463) 360 (450) 355 (444) 315 (394) 5/3/2013 Standard 3 phase Dripproof or Open Enclosure Class H 125º C 125º C British Continuous Standard 405 (506) 400 (500) 405 (506) 400 (500) 395 (494) 395 (494) 390 (488) 380 (475) 380 (475) 380 (475) 365 (456) 375 (469) 315 (394) 315 (394) 315 (394) British Standard Rating per BS 5000 130º C Standby 150º C Standby 440 (550) 425 (531) 410 (513) 400 (500) 315 (394) Submittal Data: 480 Volts*, 404.8 kW, 506 kVA, 0.8 P.F., 1800 RPM, 60 Hz, 3 Phase STD. CONNECTION Mil-Std-705B Mil-Std-705B Method Description Value Method Description Value 301.1b Insulation Resistance >1.5 Meg 505.3b Overspeed 2250 RPM 302.1a High Potential Test 507.1c Phase Sequence CCW CCW-ODE ODE ABC Main Stator 2000 Volts 508.1c Voltage Balance, L-L or L-N 0.20% Main Rotor 1500 Volts 601.4a L-L Harmonic Maximum - Total 5.0% Exciter Stator 1500 Volts (Distortion Factor) Exciter Rotor 1500 Volts 601.4a L-L Harmonic Maximum - Single 3.0% PMG Stator 1500 Volts 601.1c Deviation Factor 5.0% 401.1a Stator Resistance, Line to Line --TIF (1960 Weightings) < 50 High Wye Connection 0.0137 Ohms --THF (IEC, BS & NEMA Weightings) <2% Rotor Resistance 0.297 Ohms 652.1a Shaft Current < 0.1 ma E it St t 22 5 Oh Exciter Stator 22.5 Ohms Main Stator Capacitance to ground Exciter Rotor 0.022 Ohms --0.021 mfd PMG Stator 2.1 Ohms 410.1a No Load Exciter Field Amps 0.61 A DC at 240/480 Volts Line to Line Additional Prototype Mil-Std Methods 420.1a Short Circuit Ratio 0.533 are Available on Request. 421.1a Xd Synchronous Reactance 2.553 pu -Generator Frame 433 MAGNAMAXDVR 1.162 ohms -Type 422.1a X2 Negative g Sequence q React. 0.218 p pu -Insulation Class H 0.099 ohms -Coupling - Single Bearing Flexible 423.1a X0 Zero Sequence Reactance 0.039 pu -Amortisseur Windings Full Ext. Voltage Regulated, Brushless 0.018 ohms -Excitation 425.1a X'd Transient Reactance 0.13 pu -Voltage Regulator DVR2000E+ 0.059 ohms -Voltage Regulation 0.25% 426.1a X''d Subtransient Reactance 0.108 pu 0.049 ohms -Xq Quadrature Synchronous 1.14 pu -Cooling Air Volume 1050 CFM 0 519 ohms 0.519 427.1a T'd Transient Short Circuit -Heat rejection rate 1392 Btu's/min Time Constant 0.074 sec. 428.1a T''d Subtransient Short Circuit -Full load current 609 amps Time Constant 0.006 sec. 430.1a T'do Transient Open Circuit -Minimum Input hp required 575.4 Time Constant 1.55 sec. Efficiency at rated load : 94.3% 432.1a Ta Short Circuit Time Constant of Armature Winding 0.019 sec. -Full load torque 1678 Lb-ft * Voltages refer to wye (star) connection, unless otherwise specified. www.marathonelectric.com MARATHON ELECTRIC GENERATORS TYPICAL DYNAMIC CHARACTERISTICS MODEL : 433RSL4021 BASE MODEL: 433RSL4021 1 0 0 100 200 300 400 500 Recov very time / sec. Recov very time / sec. Winding H-SG430039 Submittal Data: 480 Volts*, 404.8 kW, 506 kVA, 0.8 P.F., 1800 RPM, 60 Hz, 3 Phase 1 0 0 100 300 400 500 400 500 Load rejection Load application 30% % Volta age Rise 30% % Voltag ge Dip 200 20% 10% 0% 0 100 200 300 400 500 kW 20% 10% 0% kW 0 100 200 300 Efficiency at rated voltage and frequency vs. load kW .8 pf 1.0 pf 9 0% 97.0% 96.0% 95.0% 94.0% 93.0% 92.0% 91.0% 90.0% 0 50 100 Percent dip 150 200 250 kW Output 300 350 400 450 500 Voltage dip with motor starting 40% 35% 30% 25% 0% 20% 15% 10% 5% 0% 0 500 1000 1500 2000 2500 Locked rotor kVA www.marathonelectric.com