Download Lighting and Heating control

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Buck converter wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

History of electric power transmission wikipedia , lookup

Voltage optimisation wikipedia , lookup

Electrical ballast wikipedia , lookup

Opto-isolator wikipedia , lookup

Switch wikipedia , lookup

Potentiometer wikipedia , lookup

Electrical substation wikipedia , lookup

Mains electricity wikipedia , lookup

Rectiverter wikipedia , lookup

Distribution management system wikipedia , lookup

Light switch wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

LED lamp wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Transcript
Tender Specification
SFTUNWD-082011
Wiring Devices
This specification sheet provides a summary of features relating to wiring devices
Wiring devices
1
Last updated on:
Tender Specification
SFTUNWD-082011
Table of contents
General
Construction
Installation
Component Specifications
Environmental directives
Wiring devices
2
Last updated on:
Tender Specification
SFTUNWD-082011
General
Wiring devices include all electrical and related fixtures which act to control the flow of
electric current such as switches, power sockets, Data sockets, Dimmers, etc.
Construction
The range shall offer mounting frames at 71mm or 57mm horizontally and vertically.
The aesthetics shall have in at least 4 color variants. Aesthetical frames shall allow
flexibility to mount 3, 4 modules, 2 rows of 4 modules and 2 rows of 6 modules.
Installation
Range shall be flush mounting, with provision for absorbing wall variations.
No screws will be visible after final installation.
Products must all be compatible with mounting on CE60 boxes.
Mounting on flush boxes will be made with screws on mounting frames made of Zamak
provided in the range.
For media claws, accessory claw extension is available in cases where the back-box is
placed too deeply. This accessory enhances the depth of 10 mm claws standards.
Components are fitted with quick connect terminals on mounting brackets without
screws.
Component specifications
1) Power Sockets
The sockets must be of type 2P + E. 2P is also a model for renovation projects only.
The capacity of the terminals must be 2 x 2.5 mm2. Color identification must be available
to differentiate phase terminals and Earth terminals. The rear connection terminals are
aligned, whatever the model outlet.
Taken for screwless terminals, strip length of the conductors is 11 mm, the
conductorshould then be inserted without tools to ensure the connection. Disconnection
of conductors is accomplished by simultaneously pressing the disconnect button and
dragging with a rotation of 1 / 4 turn on the driver.
Non removable Child protection mechanisms must be present in all sockets
2) Button Switches PUSH
The range must include:
A) 10A Switches
- One-way, 1 and 2 modules, screwless
Wiring devices
3
Last updated on:
Tender Specification
SFTUNWD-082011
- Two-way, 1 and 2 modules, screwless
- Two-way with LED locator pre-wired, 1 and 2 modules, screwless
- Two-way with indicator light pre-wired, 1 and 2 modules, screwless
- Double two-way switch module, 2 modules, screwless
- Double one-way switch, 2 modules, screwless
- Intermediate switch, 1 and 2 modules, screwless
- Switch for shutters, 2 modules, screwless
B) 16A Switches
- Double pole, 2 module, screw terminals
- Double pole, 2 modules with indicator light pre-wired, screw terminals
- Two-way, 2 module, screw terminals
C) Pushbuttons
- Push-button, NO, 1 and 2 modules, screwless
- Push-button, NC, 1 and 2 modules, screwless
- Push-button with LED locator NO pre-wired modules 1 and 2, screwless
- Push-button with bell symbol NO, 2 modules, screwless
- Push-button 12V NO with label holder, 2 modules, screwless
- Push-button for shutters, 2 modules, screwless
- Cord push-button, 2 modules, cable length 1 meter, screwless
3) Movement Detectors
Movement detectors must be equipped with two optical lenses to allow adjustment of the
detection to 90° right, 90° left or 180°. Movement detectors must be equipped with a
timer with 2 seconds to 20 minutes to extinguish after detecting the last movement. The
detectors must also be equipped with a potentiometer for adjusting the brightness
threshold from 5 to 1000 lux. Movement detectors can be set to automatic or
manual.Access to these different settings must be done in front of the product by
removing the plate beneath the infrared lenses.
For installation of the detector at 1.20 m above the ground, the detection range must be
around 9 meters by 18 meters. It should also be possible to transfer the command
manually with 5 buttons up related to the movement detector.
There must be two models:
- Two wire connection: command up to 300 W incandescent lamps and up to 300 W
halogen lamps 230 V AC
- Three wire connection: command up to 2300 W incandescent lamps, halogen lamps
2000 W 230 V AC, 1050 VA low voltage halogen lamps with wire-wound transformer
(non toroidal), 1150 VA low voltage halogen lamps with electronic transformer, 500 VA
compact fluorescent lamps, 200 VA fans, 2300 W convectors and 200 VA contactors.
Wiring devices
4
Last updated on:
Tender Specification
SFTUNWD-082011
4) Timer switch
For control of incandescent lamps to 1840 W halogen lamps to 1840 W, low voltage
halogen lamps with ferromagnetic transformer.
The interval of the delay setting is 2 seconds to 12 minutes. The time switch must have a
blue LED tracking. Standard push buttons can also be used for manual control of the
load. Up to 25 illuminated pushbuttons and 5 illuminated pushbuttons can be installed for
manual control.
5) Dimmers
A) Rotary Dimmer 400 W
This drive must allows you to adjust the lighting of incandescent and halogen 230V from
40 to 400 W. It must also allow use with low voltage halogen lamps with ferromagnetic
transformer (non totoidal) up to 400 VA.
Pressing the center button must allow switching on or switching off, whie variation must
be achieved by rotating a knob.
A potentiometer for adjusting the minimum level of brightness must be located near the
front of the dimmer.
The dimmer can also be used in combination with a normal switch.
B) Rotary dimmer 1-10 V 400 VA
This drive lets you adjust the fluorescent lighting 1-10V, up to 400 VA.
Pressing the center button allows switching on or switching off, the variation is achieved
by rotating the knob.
A potentiometer for adjusting the minimum level of brightness is located under the front
of the dimmer.
C) Variable Universal pushbutton 350 W
This dimmer must allow you to adjust the lighting of incandescent and halogen 230V
from 20 to 350 W. It also should allow use with low voltage halogen lamps with
ferromagnetic, toroidal or electronic transformer 350VA. It also should allow for use with
fans up to 200 W and convectors up to 350 W. Continuous pressing should allow the
variation of light intensity, a short press should turn the power on or power off.
A potentiometer for adjusting the minimum level of brightness must be located nearthe
front of the dimmer. The dimmer can also be used in combination with push buttons: up
to 25 non-illuminated pushbuttons and 5 illuminated push buttons.
D) Rotary Dimmer 1000 W
This dimmer should allow you to adjust the lighting of incandescent and halogen lights at
230V from 40 to 1000 W. It should allow use with low voltage halogen lamps with
ferromagnetic transformer (non toroidal) up to 1000 VA. This dimmer should also have
provisions to be used with motors up to 600 W. Pressing the center button should allow
switching on or switching off, while the variation should be achieved by rotating the
knob. A potentiometer for adjusting the minimum level of brightness must be located
near the front of the dimmer.
Wiring devices
5
Last updated on:
Tender Specification
SFTUNWD-082011
6) Shutters and cable outlets 16A
The shutter should allow closing of a function that is no longer needed or put on hold.
The shutters should be available in 1 and 2 modules.
The cable outlets must be equipped with cable ties and a terminal block that allow the
connection of 3 wires of 2.5 mm ² section each.
7) Shutter control
The shutter control is done through:
- A double switch
- A double push-button.
Markings of "up" and "down" must be present on respective buttons to identify the
feature.
8) Phone Jack
Range must provide standard Belgium phone socket.
9) TV Socket
The range must include a TV plug-FM for individual facility (terminal) and a TV-FMapproved by Telenet - Interkabel.
10) Data sockets
Computer connections options must be
RJ11 to 4 contacts
RJ45 Category 5 UTP 1 module
RJ45 Category 5 STP 1 module
RJ45 Category 6 UTP 1 module
RJ45 Cat 6 STP 1 module
RJ45 Category 5 UTP 2 modules
RJ45 Category 5 STP 2 modules
RJ45 Category 6 UTP 2 modules
RJ45 Cat 6 STP 2 modules
For RJ45, two types of connectors must be available: LexCom connectors and Infraplus
connectors.
Wiring devices
6
Last updated on:
Tender Specification
SFTUNWD-082011
Environmental directives
The Products shall meet the requirements of the RoHS directive 2002/95/CE relating to
hazardous substances included in electric and electronic devices.
The product’s environmental profile shall be made available.
Wiring devices
7
Last updated on: