Download PowerPoint-presentasjon

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
Aeon Gold – System Overview
Aeon 4000
w/Aeon Gold
& SMPS4000
*TCP/IP
*SNMP
Aeon Gold
Control Unit
Aeon Gold Display Unit
PC w/WinPower
*CAN Bus
*Advanced setup and
*monitoring through
*WinPower
*SW Download
Aeon Gold in Aeon 4000
2PR – Power
Rack System
Hinged door
Aeon Gold Display Unit
Rear view
2 rows with MCB’s for
internal distribution
Aeon Gold
Control Unit
AC MCB’s
Battery fuse
AC distribution
Load fuse
2 shelves,
each including
6 rectifiers
Aeon Gold – HW Specification
Graphical Display
Red LED
- Alarm
Green LED
- Power
3 Keys for
menu scroll
Keypad
10 Numerical keys
1 key for scroll back
User friendly interface with keypad and graphical display
System parameters can be seen and altered
Aeon Gold – HW Specification Cont.
Modem, TCP/IP, SNMP
WinPower
SW appload
10 Digital outputs (Relays)
7 Digital inputs
Red LED, when
in service mode
Upper position- control unit
alarm
Enabling sw
appload
Aeon Gold – HW Specification Cont.
Green LED, Heartbeat
Calibration output, 60mV
Keypad
connector
2 CAN bus
connectors
Reset button
DC Fuse
System connections:
5 Current inputs
AC & DC input
5 Voltage inputs
LVLD & LVBD
2 Temperature inputs
Battery & Load fuse alarm
Aeon Gold – Main Menus
Aeon Gold is divided into three main menus:
Aeon Gold
Graphical display
User Setup
Service Setup
Password Protected
Factory Setup
Password Protected
User Setup: Information accessible for everyone,
Read only.
Service Setup: Password protected, setup and
changing parameters.
Factory Setup: Password protected, installation
setup, usually done at factory.
Aeon Gold – Menu Structure
Aeon Gold
Graphical display
User Setup
Service Setup
Password Protected
Factory Setup
Password Protected
Alarm Info
Stop Test/Boost
Controller Setup
Alarm Reset
System ON/OFF
Diagnostics
Rectifier Status
Rectifier Control
Voltage Info
Voltage Config.
System Info
System Config.
Service Info
Battery Config
Battery Info
Communication
Input Monitor
Master Password
Aeon Gold - Functionality
Features:
Output voltage monitoring and control
Load and battery current monitoring and
control
Individual rectifier control
Temperature compensated charging
Boost charging
Battery testing
Fuse monitoring
Aeon Gold – Functionality Cont.
Features:
Alarm log
LVD disconnect for load and/or battery
Advanced alarm/event setup
Advanced configuration of relay outputs
Communication through IP
Symmetry monitoring
Capacity and backup time calculation
Aeon Gold – WinPower 4000
A Windows NT, Windows
98 software package for
Aeon Gold.
All configuration and
change of parameters
can be done here.
Communicating with
Aeon Gold through
PCOMM protocol.
Configuration of relay
outputs and trend data
is not available from
graphical display.
Winpower must be
used.
Aeon 4000 – Autoboost
(Dynamic Current Limiting & Equalize Thermal Stability)
Recharge (% of discharge) =
Boost factor [100-150%]
Battery Temp. limit reached
58
Battery Voltage (V)
56
56,0V
54,5V
54
52
50
48
Discharge > Threshold = Autoboost
Discharge < Threshold = Float
46
44
Mains OK
Mains failure
Mains OK, Autoboost
Mains
Mains OK, Float
Battery Current (A)
Aeon 4000 – Intelligent Re-charge
Battery current limit [A] = 0.3*C10
Float current
Mains OK
Mains failure
Mains OK, Recharge
Load current
Mains
Mains OK
Aeon 4000 – Temperature Comp.
Output Voltage [Vdc]
55,5
55
54,5
Slope
54
53,5
53
52,5
Min Comp, volt
o
Max Comp, Volt
Temperature T [ C]
Charge voltage is temp. dependant
Prevents gassing at high temperature
Obtain max. charging at low temperature and
maintain capacity
Aeon 4000 – Energy Management
1 shelf including 6 rectifiers, power output equal 450 A
When a fully equipped shelf powers a 200A load, we
have 2 scenarios. Aeon 4000 can handle both.
Current sharing between 6 rectifiers, which
means low efficiency and high utility cost
Current sharing between 3 rectifiers, with
decreased AC input current and high efficiency
6 rectifiers
Irect.=200Amp/6
Irect.=34 Amps
3 rectifiers
Irect.=200Amp/3
Irect.=66 Amps
Low Efficiency
High Efficiency
Related documents