EOP-P61-003-6-001-06E/a PRODUCT SPECIFICATIONS for MODEL EG/EL-550 In-line type OZONE MONITOR Published on August 01, 2011 EBARA JITSUGYO CO., LTD. MEASURING INSTRUMENT AND MEDICAL DIVISION MEASURING INSTRUMENT SALES DEPARTMENT EAST JAPAN SALES BRANCH : 3-12, Kurigi 2-Chome, Asao-ku, Kawasaki-shi, Kanagawa, 215-0033 Japan Tel. +81-44-981-0560 Fax. +81-44-981-0561 E-mail [email protected] WEST JAPAN SALES BRANCH : 2-13, Hiranocho 3-Chome, Chuo-ku, Osaka-shi, Osaka, 541-0046 Japan Tel. +81-6-6231-3528 Fax. +81-6-6231-2929 E-mail [email protected] TECHNICAL ENGINEERING DEPARTMENT 3-12, Kurigi 2-Chome, Asao-ku, Kawasaki-shi, Kanagawa, 215-0033 Japan Tel. +81-44-981-0560 Fax. +81-44-981-0561 E-mail [email protected] E.J. OZONE PRODUCTS EOP-P61-003-6-001-06E/a Introduction The EG/EL-550 series, Ozone monitors designed on the specifications in this document, are USED for general application only, so that you can not use them in explosion environments. DANGER Explosion can result in death or serious injury. Do not USE this Ozone monitor in the explosive environments. - E.J. OZONE PRODUCTS 1 - EOP-P61-003-6-001-06E/a 1. General Description The ozone densitometer (hereafter referred as ozone monitor), EG/EL-550 series was actualized as a small instrument by designing the detector unit and the control unit to one package. Moreover, by only connecting a pipe on inlet for sample, the monitor can measure ozone concentration continuously. Still more, to indicate a light intensity for sensor and also value for span is available, so that can easily check the monitor and perform the maintenance. 2. Measuring Principle The monitor is a UV absorption type ozone monitor which detects and measures an absorptive quantity of UV rays by ozone in the sample gas (water) introduced into the monitor, and measure ozone concentration. A low-pressure mercury lamp (emission wavelength 253.7 nm) is used for the light source. As the light intensity absorbed by ozone existing within the optical path "T" obeys the Lambert-Beer's Law, ozone concentration can be measured as follows. C= A × Log αT Where; C α T Io Ix A = = = = = = Io Ix ・・・・・ equ. 1 Ozone concentration of sample Specific absorption coefficient Path length of cell Light intensity through the sample free of Ozone Light intensity passed through sample Ozone Constant Mercury lamp Sensor 1 Sample T Sensor 2 Figure 1: Logic Diagram - E.J. OZONE PRODUCTS 2 - EOP-P61-003-6-001-06E/a 3. Specifications 3.1 Dissolved ozone monitor Model : EL-550 Measuring principle : UV absorption method Object of measurement : Dissolved ozone in water Measuring Range : One range to be selected from among the following. 0~10 mg / L 0~20 mg / L 0~30 mg / L 0~50 mg / L 0~100 mg / L Note Measuring Interval Note : The monitor can measure high ozone concentration, but it can not be guaranteed that the piping and etc. are not deteriorated by ozone reaction. : Continuous measurement : Before supplying sample water, confirm zero point of the monitor Sampling Method : Intake from water pressure itself or pressure sucked with pump Sample flow rate : 0.05 ~ 3.0 litter per minute Note : When measuring the concentration at low flow late, pipe length should : be as short as possible so as not to decompose easily ozone. Continuous service Pressure : Less than 0.1 MPa (G) Span Drift : Within ± 1% of full scale per month Zero Drift : Within ± 3% of full scale per month Linearity : Within ± 1 % of full scale Repeatability : Less than 1 % of Full Scale Zero Adjustment : Adjustment with zero trimmer - E.J. OZONE PRODUCTS 3 - EOP-P61-003-6-001-06E/a Display function : Available (selection of ozone concentration, light intensity on the sensor, or span with rotary switch) Analog output : Voltage output ・・・・・ 0 ~ 1 V or 0 ~ 10 V DC Current output ・・・・・ 4 ~ 20 mA DC (isolated) Note (1) : Allowable resistance to be connectable, is over than 10 k Ω when voltage output. Specify either 1 V or 10 V when ordering. It is set before shipping. Note (2) : When current output, a resistance externally connectable is less than 750 Ω. Power requirement : 90 ~ 260 V AC, 50/60 Hz Connection method of power supply : Connection through a terminal block Power consumption : 50 VA Dimension : 220 W × 150 H × 105 D Note Piping connection : Protruding parts are not included : Flowell TM , 20 series, 1/4 inch PTFE Operating environment : 5 ~ 45 ℃, 90 % RH (non condensation) Enclosure material : SUS 304 Weight : 2.2 kg Accessory : Fuse ( 250 V AC, 1 A approved by UL) Options : Function for preventing the condensation. (needs dry air of 0.1 liter per minute) : Power supply for 24 V DC Note : The monitor should be installed in the system cabinet. - E.J. OZONE PRODUCTS 4 - EOP-P61-003-6-001-06E/a 3.2 Gas-phase ozone monitor Model : EG-550 Measuring principle : UV absorption method Object of measurement : Ozone gas Measuring Range : One range to be selected from among the following. 0~10 mg / m3 0~20 mg / m3 0~30 mg / m3 0~50 mg / m3 0~100 mg / m3 Note Measuring Interval Note : The monitor can measure high ozone concentration, but it can not be guaranteed that the piping and etc. are not deteriorated by ozone reaction. : Continuous measurement : Before supplying sample water, confirm zero point of the monitor Sampling Method : Intake from gas pressure itself or pressure sucked with pump Sample flow rate : 0.05 ~ 3.0 litter per minute Note Continuous service Pressure Note : When measuring the concentration at low flow late, pipe length should be as short as possible so as not to decompose easily ozone. : Less than 0.1 MPa (G) : But, outlet of the monitor should be free to atmosphere, when measuring the ozone. When the outlet is influenced with a pressure, perform to compensate the pressure. Span Drift : Within ± 1% of full scale per month Zero Drift : Within ± 3% of full scale per month Linearity : Within ± 1 % of full scale Repeatability : Less than 1 % of full scale Zero Adjustment : Adjustment with zero trimmer Display function : Available (selection of ozone concentration, light intensity on the sensor, - E.J. OZONE PRODUCTS 5 - EOP-P61-003-6-001-06E/a or span with rotary switch) : Voltage output ・・・・・ 0 ~ 1 V or 0 ~ 10 V DC Current output ・・・・・ 4 ~ 20 mA DC (isolated) Analog output Note (1) : Allowable resistance to be connectable, is over than 10 k Ω when voltage output. Specify either 1 V or 10 V when ordering. It is set before shipping. Note (2) : When current output, a resistance externally connectable is less than 750 Ω. Power requirement : 90 ~ 260 V AC, 50/60 Hz Connection method of power supply : Connection through a terminal block : Power consumption : 50 VA Dimension : 220 W × 150 H × 105 D Note Piping connection : Protruding parts are not included : Flowell TM , 20 series, 1/4 inch PTFE Operating environment : 5 ~ 45 ℃, 90 % RH (non condensation) Enclosure material : SUS 304 Weight : 2.2 kg Accessory : Fuse ( 250 V AC, 1 A approved by UL) Options : Function for preventing the condensation. (needs dry air of 0.1 liter per minute) Power supply for 24 V DC Note : The monitor should be installed in the system cabinet. - E.J. OZONE PRODUCTS 6 - EOP-P61-003-6-001-06E/a 4. Code Number EG ozone gas EL dissolved ozone ・ - 550 measurig power piping analog mounting privation ranges rating connection output method of [ mg/L ] 0 ~ 10 J [V] A 90 ~ ※3 2 TM Flowell 260 AC 20 series 24 DC inch pipe V1 0~ ※2 condensation B wall 1 available F Floor 0 none 1V DC for OD 1/4 B2 0 ~ 20 B3 0 ~ 30 D ※1 V10 joint: material 0~ 10V DC PTFE U5 0 ~ 50 U10 0 ~ 100 F TM Kurabo Final lock for OD 1/4 inch junction material : PTFE + PFA ※1 Note ※ 1: Mark means an optional good ※ 2: Customer is able to change a position of the fixing metal. ※ 3: The monitor has two kind of outputs for voltages and current. Regarding voltage, there are two outputs, select it. <Example of order> Specifications 1) 2) 3) 4) 5) 6) 0 ~ 50 mg per liter (dissolved ozone) ・・・ 100 V AC power supply ・・・・・・・・・ pipe connection with FlowelTM ・・・・・ analog output of 0 1 V DC ・・・・・・・・ Mounting on the floor ・・・・・・・・・ prevention of condensation (none) ・・・ Code number: EL-550 U5A2・V1F0 - E.J. OZONE PRODUCTS 7 - U5 A 2 V1 F 0 EOP-P61-003-6-001-06E/a 5. Warranty WARRANTY:We warrant the ozone monitor as follows. (1) ・ (2) ・ Warranty period 12 months after customer's acceptance inspection. Condition The ozone monitor should be operated under the specified condition deserved in this instruction manual. (3) Limitation of warranty ・ Liability and obligations are limited to the supply of parts for replacements. - E.J. OZONE PRODUCTS 8 - EOP-P61-003-6-001-06E/a - E.J. OZONE PRODUCTS 9 - EOP-P61-003-6-001-06E/a MEMO - E.J. OZONE PRODUCTS 10 - 荏 原 実 業 株 式 会 社 計測器・医療本部 計測器営業部 ■東日本営業課:〒215-0033 神奈川県川崎市麻生区栗木2丁目3番12号 TEL 044-981-0560 FAX 044-981-0561 E-mail ej-ozone@ejk.co.jp ■西日本営業課:〒541-0046 大阪市中央区平野町3丁目2番13号 平野町中央ビル5階 TEL 06-6231-3528 FAX 06-6231-2929 E-mail ozon-osaka@ejk.co.jp 技 術 部 :〒215-0033 神奈川県川崎市麻生区栗木2丁目3番12号 TEL 044-981-0560 FAX 044-981-0561 E-mail ejozndsn1@ejk.co.jp 取扱店: