Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Centralised ventilation unit WS 160 Flat BET Features Centralised ventilation unit with heat recovery for comfort ventilation. The WS 160 Flat… range of units is characterised by its compact and very flat design. The total height of just 23 cm makes space-saving installation possible in suspended ceilings. The highly efficient enthalpy heat exchanger fitted as standard means there is no need for a condensate drain. The installer is therefore free to select the unit's position on any ceiling, wall or inclined surface. Other benefits of the enthalpy heat exchanger with intelligent humidity control include humidity recovery and the ideal room climate, even in winter. The housing consists of expanded polypropylene (EPP) with thermal and sound insulation. The housing's EPP cover is covered with sheet steel for enhanced sound insulation. The flat units are very quiet, energy-efficient and hold an A-rating label in accordance with the ErP Directive. The fans with constant volumetric flow cover a volumetric flow range of 40 to 160 m³/h. The two supply air connections (fitted as standard) allow the supply air lines to be configured without crossing one another. There is therefore no need for unit variants in lefthand and right-hand versions. As standard, the unit has an F7 filter in the outside air and a G4 filter in the exhaust air. As an option, a G4 filter can also be retrofitted in the outside air. This filter cascade greatly extends the service life of the F7 filter. The controller is able to control a large number of external components, such as brine pump, external room heating or shutter for air/earth heat exchanger, and to extend the scope of the ventilation concept. KBZET variant: The use of the motorised zone shutter and needs-based zone regulation allows the supply air rooms to be split into 2 zones. Regulation of the volumetric flows between the 2 zones can be stored in the time programme or regulated by corresponding air quality sensors in the zones. BET, KBET, KBZET variants: The integrated bypass shutter (100 % bypass) with needsbased bypass control makes continuously variable bypass control possible. Depending on temperature differences and user settings, the room air can be cooled in an optimum manner without draughts. KET, KBET, KBZET variants: The performance-controlled electrical preheating register is regulated depending on various parameters recorded in the unit. The result is an efficient and energy-saving regulation strategy. Ventilation with a heat register therefore does not compromise on comfort even at low outside air temperatures. RLS 1 WR control unit Included in the scope of delivery. Switching the 4 ventilation levels, maintenance display, fault messages. Other control units can be connected in parallel. Auto Sensor automatic operating mode. Touch screen control unit RLS T1 WS Optional. Up to 6 operating modes possible. 2 automatic operating modes (Auto Sensor / Auto Time). 4 manual operating modes (ECO exhaust air / ECO supply air / MANUAL / OFF). air@home The units have an integrated web server. Can be controlled with an app when at home or out and about, e.g. using a smartphone. Live reports, user administration, control and setting using web tool. Via tablet, laptop and PC. Needs-based automatic mode / Time-controlled automatic mode. Manual operation / OFF. ECO mode supply air or ECO mode exhaust air. Filter queries, error messages. Registration needed. For more info, see www.air-home.de. Controller 3 temperature sensors in outside, outgoing and supply air connections. 1 combination sensor (temperature and humidity) in exhaust air connection. Integrated excess humidity avoidance function. Continuously variable needs-based adaptation of air volumes. Multi-function contact for controlling EW brine earth heat exchanger (uncontrolled pump), operating and fault display, preheating and postheating register, shutters. Can be extended with other PCBs. ModBus Integrated MODBUS interface enables integration in the building control technology. EnOcean Optional EnOcean plug-in module for integrating the ventilation unit into "EnOcean world" www.enocean-alliance.org. KNX Optional KNX plug-in module allows for connection to building control technology, www.knx.org. Heat exchanger Washable anti-microbial enthalpy heat exchanger made from plastic (PS). Frost protection Prevents the heat exchanger from freezing up at low temperatures. For "K" unit models, using integrated, demand-controlled, electrical PTC preheating register. For "non-K" unit models, by switching off the supply air fan. Energy-efficient fans 2 centrifugal DC fans, curved to the front. In the outside air or outgoing air. 4 ventilation levels between 40...160 m³/h can be adjusted continuously. Mounting instructions Easy, very time-saving installation Housing cover is easy to remove using guide pin and safety screw. Provide sound absorbers on the inlet and outlet sides. Electrical connection Ready for service. Prepared for assembly-friendly connection of sensors. Extendible, functional electronics box allows optional additional circuit boards (ZP 1 and ZP 2) to be fitted with ease. Condensation drain Not required. Technical data Article: Number of ventilation levels: Air flow volume: Volumetric flow constant: Energy efficiency class: Type of voltage: Rated voltage: Frequency: WS 160 Flat BET 4 40 m³/h - 160 m³/h yes A Alternating current 230 V 50 Hz / 60 Hz SPI value in accordance with DIN EN 13141-7 (A7): 0,32 Wh/m³ Power consumption in accordance with DIN EN 13141-7 (A7): 36 W Imax: 1,1 A Degree of protection: IP 00 DIBT approval: PHI certification: Installation site: Applied for yes Bathroom / Kitchen / Cellar / Storage tank / Jamb wall / Utility System type: Housing material: Heat exchanger material: Inner coating material: room / Heating room / Hall Centralised Plastic EPP/sheet steel Synthetic material Plastic EPP Colour: black / white aluminium Weight: 27 kg Filter class: Connection diameter: Connection diameter of condensation drain: G4/F7 125 mm / 160 mm not required Width: 582 mm Height: 230 mm Depth: 1.260 mm Airstream temperature at IMax: -20 °C up to 50 °C Degree of heat provision: 84 % Max. heat recovery rate in accordance with DIN EN 13141-7 (A/7): 76 % Heat exchanger construction type: Humidity conditions with enthalpy heat exchanger in accordance with DIN EN 13141-7 (A2): Enthalpy cross-counterflow 53 % Bypass, integrated: yes integrated frost protection: No Enthalpy heat exchanger: yes Antifreeze circuit: yes Summer circuit: Filter monitoring: Humidity control: CO2-control (optional): Air quality control (optional): KNX connection (optional): MODBUS interface: Control unit included in scope of delivery.: Control unit (optional): EnOcean wireless integration (optional): ECO exhaust air / ECO supply air time-controlled (controlled by differential pressure as option) integrated SKD EAQ 10/3 K-SM integrated RLS 1 WR, App RLS T1 WS E-SM Mobile control: Housing emission sound pressure level: yes 37 dB(A) Spacing 1m, sound absorption 10 m² Packing unit: 1 piece Range: EAN: K 4012799950929 Article number: Manufacturer: MAICO WS 160 Flat BET Centralised ventilation unit 0095.0092