Download DC to DC Isolated Converter

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Immunity-aware programming wikipedia , lookup

Virtual channel wikipedia , lookup

Ohm's law wikipedia , lookup

Audio power wikipedia , lookup

Standing wave ratio wikipedia , lookup

Multimeter wikipedia , lookup

Josephson voltage standard wikipedia , lookup

Radio transmitter design wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Amplifier wikipedia , lookup

Power MOSFET wikipedia , lookup

Integrating ADC wikipedia , lookup

Wilson current mirror wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Current source wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

CMOS wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

Surge protector wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Operational amplifier wikipedia , lookup

Schmitt trigger wikipedia , lookup

Current mirror wikipedia , lookup

Voltage regulator wikipedia , lookup

Power electronics wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Rectiverter wikipedia , lookup

Transcript
Prices as of April 27, 2016. Check Web site for most current prices.
RHINO DC to DC Isolated Converter
This isolated DC to DC power supply is used
for eliminating ground loops or addressing
isolation issues when interfacing to PLC
analog I/O modules. The design features
handle many types of configuration problems. The FA-DCDC-1 is a DIN-rail mount,
±10VDC, ±5VDC isolated power supply,
with each output rated at 125mA. The
input voltage range is 12-24V DC ±15% at
approximately 6.7 Watts.
FA-DCDC-1
$64.00
FA-DCDC-1 General Specifications1
Input Voltage Range
Input Power 2
Output Voltage 3 (25°C)
Output Current
Output Ripple
Line Regulation 4
Load Regulation 5
Isolation
Inrush Current (50ms)
Holdup Time (all channels)
Overshoot Protection
Input Protection (reverse DC input voltage)
Overload Protection
Output Protection
Peak Line Transient Voltage
Operating Temperature
Storage Temperature
Enclosure
Mounting
Connection
Relative Humidity
Environmental Air
Vibration
Shock
Noise Immunity
Agency Standards and Approvals
12V to 24VDC ± 15%
6.7 Watts, Vin 27.6V, 125mA load each channel
+5V ±1%, 125mA load,-5V ±1% 125mA load
+10V ±1% typical, ±2% maximum; -10V ±1% typical, ±2% maximum
125mA (per output voltage)
±5V channels: <10mV peak to peak, Vin 10.2V 125mA load on both channels
±10V channels: <25mV peak to peak, Vin 10.2V, 125mA load on both channels
±5V channels: <10mV, Vin 10.2V to 27.6V, 125mA load on both channels
±10V channels: <20mV, Vin 10.2V to 27.6V, 125mA load on both channels
±5V channels: <20mV, Vin 10.2V, 0 - 125mA load variation
±10V channels: <40mV, Vin 10.2V, 0 - 125mA load variation
Input to Output: 1500V; ±5V to ±10V: 1500V
970mA, Vin 10.2V, 125mA load all channels
30mS minimum, Vin 10V, 125mA load all channels
No overshoot - Turn on and turn off of Vin
Up to -50V reverse. ± Vin reverse polarity connection.
Auto shutdown. Short circuit. Cycle Vin post event
Indefinite duration. ±5V tied to ±10V
100V for 10mS. Voltage spike on input
0 to 60°C (32 to 140°F) full rated
-20 to 70°C (-4 to 158°F)
Clear Lexan 221-111 with UN5016 transparent blue colorant
35mm wide DIN rail: part # DN-R35S1 or DN-35HS1; surface mount
3.5mm screw terminal, 28-16AWG, 1.7 lb-in torque
5 to 90% (non-condensing)
No corrosive gases permitted
MIL STD 810C 514.2
MIL STD 810C 516.2
NEMA ICS3-304
UL/cUL listed, UL file E200031, UL508/CSA - C22.2 No. 142-M1987 for ordinary locations.
Class I, Division 2, Groups A, B, C, D Hazardous Locations
Notes: 1 . All specifications are over the full operating temperature range (0°C to 60°C) unless stated otherwise.
2. “Channel” means Output Voltage. For example: +5V is one channel and -10V is another.
3. All output voltage channels are independent of each other. Changing loading on one will have no effect on the other voltage outputs.
4. LINE Regulation: varying the Input Voltage over entire range (12V to 24V ± 15%) and the resultant change in the Output Voltage(s) under worst case load
conditions (all output channels drawing 125mA).
5. LOAD Regulation: varying the output loads from no-load to a worst case 125mA load and measuring the resultant change in the Output Voltage(s) under a
worst case minimum Input Voltage (10.2V) condition.
"B"
V+
Com
12-24 V o lt
*internal
diagram
10-30 Volt
Controller
± 5 Volt Regulator
+5
Com2 -5
" C"
± 10 Volt Regulator
+10
Com1
-10
"A"
Book 3 (14.3)
www.automationdirect.com/dc-power-supplies
Power Supplies
ePW-69
Prices as of April 27, 2016. Check Web site for most current prices.
RHINO DC to DC Isolated Converter
Applications
Wetting Resistive Device
IN
Isolated Module Power Supply
ANALOG
4CH
ANALOG
2CH
+10V
COM1
+10V
+10V
Com1
18--30VDC
80mA
ANALOG IN
0--5VDC
- 5--+5VDC
0V
0V
+24V
+V
CH1--
COM
Resistive
Device
0 - 10V
FA-DCDC-1
FA-DCDC-1
Wiper
0V
+25V
+V
0V1
+V1
+V
CH1-V
COM
CH1+
* output in mV
N/C
CH2+
N/C
CH3--
0V2
CH3+
+V2
CH4-+5V
CH4+
0--10VDC
- 10--+10VDC
Com2
CH2-V
(Fig. 2)
F 2--04AD--2
(Fig. 3)
CH2+V
F 2--02DAS --2
When using a linear potentiometer, the +10V connects to the high
side of the potentiometer and the COM1 becomes the zero volt
reference. The wiper connects to the analog input. The result is 0
to 10V at the analog module input. (Fig. 1)
IN
TEMP
VOLT
F 2--04THM
COM
CH1+V
CH2--
(Fig. 1)
Load
Cell
- 10V
F 2--04AD--2
+V
Load Cell Application
OUT
FA-DCDC-1
FA-DCDC -1
CH1+
CH1
CH2+
CH2
CH3+
CH3
CH4+
CH4
+24V
0V
Note: F2-04THM must be set
for proper voltage range.
Use in a solar/battery application where unregulated 12VDC is available and the analog module requires 24VDC for operation, connect
the +10V to +24V module power, connect the -10V to the +5V and
the COM2 to the 0V module power. (Fig. 2)
Use to power a load cell application. (Fig. 3)
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2/ZONE 2, GROUPS A, B, C AND D NON-HAZARDOUS LOCATIONS ONLY.
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR
CLASS I, DIVISION 2/ZONE 2.
WARNING - EXPLOSION HAZARD - DO NOT CONNECT OR DISCONNECT CONNECTORS OR OPERATE
SWITCHES WHILE CIRCUIT IS LIVE UNLESS THE AREA IS KNOWN TO BE NON HAZARDOUS.
Dimensions, in(mm)
Dia. 0.24 (6.2)
Dia. 0.24 [6.2] (2)
FA-DCDC-1
+10
+10V 125mA
COM1
COM1
-10
-10V 125mA
A
FA-DCDC-1
DC DC CONVERTER
± 5VDC ISOLATED
± 10VDC ISOLATED
12-24V DC
V+
COM
4.06 [103.0]
4.53 [115.0]
12-24VDC ±15%
3.07 [77.9]
COM
B
+5
+5V 125mA
COM2
COM2
-5
-5V
C
125mA
4.34 [110.1]
0.91 [23.0]
4.67 [118.6]
Book 3 (14.3)
ePW-70
Power Supplies
1-800-633-0405