Annex - B Technical Compliance Sheet The following Technical data shall be furnished and filled by the bidders: 1-General 90 KVA (Prime Power) Generator # 1- Description Make: 2 Name of manufacturer Country of origin Reference standards: Ambient temperature : 345- 678910 1112 Relative Humidity : Altitude: System Voltage : No of phase : Frequency: Guarantee: Generator output Range 13 Maine MCCB breaker 14- Daily base tank 15 Submit Manufacturers’ UNDP specifications Original manufacturer (Locally assembled not acceptable) Offered specification IEC/ISO Maximum:55/C Minimum:-10/C 92% maximum 1000M above MSL 400V 3PH 50Hz one year ,1000HR / operation 90 KVA prime load at 55 deg 4pole 160 A… Minimum 8 -10 hour fuel capacity certification : 2-ENGINE 1- Description Make / Model : 234567891011- Name of manufacturer Country of Origin Reference standards: RPM: Prime : Type of Governor: Overload rating: Fuel filter : Type of fuel : Type of starting UNDP specifications Original manufacturer (Renovated, Engine not acceptable) ISO Maximum 1500 90 KVA prime load at 55 deg Mechanical /Electronic As per International standard Standard water separator filter Diesel 24 Volt DC Offered specification Annex - B Radiator–fan cooled–fan to be driven by the engine shaft. Turbo charge Indicator Submit :Operation and maintenance manual Submit Detail drawings, brochures and catalogues Submit type test certificates or reports 12- Type of cooling: 13141516- 3-Alternator Description UNDP specifications Make/Model : Name of manufacturer: Country of Origin IEC Reference standards: 0.400 KV Rated Voltage : 90 KVA Prime power at 55 deg C: Between 0.8 and 1 Rated power factor : 3Ph No. of Phase : 50Hz Frequency: Brushless, self-regulation Type of excitation: + -5% Percentage voltage regulation : Not less than 23 IP : Class H Insulation type : Digital AVR type : Submit detail drawings, brochures and catalogues Submit type test certificates or reports Offered specification 4-CONTROL PANEL Description Make / Model : UNDP specifications CONTROLLER INFORMATION Instrumentation tachometer switch switch Offered specification Annex - B SHUTDOWNS Fire Alarm . Submit detail drawings, brochures and catalogues 5-Automatic Transfer switch Description Make: UNDP specifications Original manufacturer (Locally assembled not acceptable) Offered specification Name of manufacturer: Country of Origin: Reference standards: IEC 60947 0.4 kV Rated voltage : 200 A Rate current : Submit detail drawings, brochures and catalogues 6-Enclosure Description Make: Noise Level : UNDP specifications Original manufacturer (Locally assembled not acceptable) Below 95 dB at a distance of 1meter. Offered specification