LM‐321/322
Multi‐function level meter
LM‐321
LM‐322
[ Summary ]
This portable “Multi‐Function Level Meter” (LM‐321/LM‐322) is suitable for maintenance of
communication equipment and analyzing in‐field operation in voice frequency band. It is
equipped with several essential devices such as, oscillator, level meter, voltmeter and
ohmmeter.
[ Features ]
・ Oscillator
・ Level meter
・ Voltmeter
・ Ohmmeter
・Filter (for LM‐322)
・Frequency counter ・Monitor function ・Peak‐Hold function
・Unique frequency measurement ・Talk function ・Data storage function
(for LM‐322)
It is composed of oscillator, level meter, AC and DC voltmeter and ohmmeter. Due to its
light weight and small size, it is convenient as a hand‐held type device.
It is equipped with ITU‐T O.41 Psophometer filter, BPF and BEF to evaluate voice
communication lines. Weighted‐noise measurement or measurements of cross talk etc.
is also simple.
Frequency counter works together with the level meter to identify the frequency of the
measuring signal.
Monitor function works together with the level meter. The signal in measuring
can be listened by the speaker (or handset).
By the Peak‐Hold function, maximum and minimum values are measured, so that the variation span of signal level, voltage and resistance for a long period can be easily identified.
By a single frequency measuring function, it is possible to measure the answer tone of facsimile and modem.
Talk between two terminals on 4W‐line can be operated. Measured data can be stored in the MMC (Multi Media Card) as CSV format, which can
be transferred to the personal computer in the form of spreadsheet program and thus
it is editable.
Specification
Item Specification Specification LM‐321 LM‐322 Input impedance range 600Ω ( 600Ω±2% ) Balance or HIGH (more than 50kΩ)
Frequency Meas. range 80Hz ~ 25kHz L
E
V
E
L
Filter
M E
T
E
R
Level range for measurement
‐60 ~ +10dBm
(↑/↓:Over/under flow display) Accurate/Resolution
in level measurement
<±1.0dB for 80Hz~300Hz, < ±0.5dB for 300kHz~4kHz, < ±1.0dB for 4kHz~25kHz
/ Display resolution : 0.1dB
Absolute Max input +20dBm
O
S
C
I
L
L
A
T
O
R
D
C
V M
・T
R
A
C
V M
・T
R
O
H
MM
E
T
E
R Filter Psophometer
Filter Characteristic:ITU‐T 0.41 Conforming
Band Pass Filter/Band Elimination filter
f0:800Hz、1000Hz、1020Hz、1500Hz
Passband:f0±10Hz; attenuation:f0±10dB
Stopband:f0±100Hz; attenuation:>45dB
FLAT ‐60 ~ +10dBm FILTER ‐70 ~ +10dBm
(↑/↓:Over/under flow display) ※When in HIGH‐Z mode, it can be connected to normal subscriber lines Frequency counter 80Hz ~ 25kHz / Display resolution : 1Hz / Error:±2Hz (in sinusoidal wave measurement) Output Impedance 600Ω Balance (within 600Ω±10%) Output Frequency
200Hz~25kHz MANUAL:Frequency selective with 10Hz step STEP1:0.3/0.6/0.8/1.0/1.3/1.5/1.8/2.0/2.5/3.0/3.4kHz
STEP2:0.2/0.3/0.4/0.6/0.8/1.0/1.5/2.4/3.0/3.4/3.5kHz Output Level
‐50 ~ +5dBm / Level selective with 1dBm step
Freq. Accuracy Within ±0.01 % Accuracy in output level
200Hz~300Hz:<±0.5dB, 300~4kHz:<±0.2dB, 4kHz~10kHz:<±0.3dB,
10kHz~25kHz:<±0.5dB Signal purity Total distortion :< ‐40dB, at frequency of 300Hz~3.4kHz, at level of 0dBm
Impurity level :4kHz~ 8kHz:< p‐30dB, 8kHz~12kHz:< p‐50dB, 12kHz~50kHz
:< p‐60dB, P:1kHz/0dBm Measuring Voltage range 0~±300V (↑↓:Overflow / Underflow display) Accuracy < ±(0.5% reading ± 2digit) Input resistance > 5MΩ Absolute Max. Vin 500V (for DC / AC voltage) Meas. V. range 0~300V (↑:Overflow display) Accuracy < ±(2% reading ± 2digit) Input resistance 5MΩ Absolute Max. Vin 500V (for DC / AC voltage) Measuring Ω range 0~3MΩ (↑:Overflow display) Accuracy /Resolution in display Accuracy : < ±(2% rdg ± 2digit)
Resolution : 0Ω~999Ω、1.000kΩ~3.299kΩ:1Ω 3.30kΩ~32.99KΩ:10Ω
33.0kΩ~329.9KΩ:100Ω 330kΩ~999kΩ、1.000MΩ ~3.000MΩ: 1KΩ
Absolute Max. Voltage 450V (for DC / AC voltage) Connection check Buzzer sounds for less than 200Ω
Peak‐Hold function Max. & Min values in current measurement are held after the function ON Unique frequency
measurement function A frequency setting
: Between 300Hz ~ 24kHz with 10Hz step
Detectable freq. Width : The frequency selected ±50Hz (Error: within ±5Hz)
Detection time : Continuous detection more than 1500msec
Talk function Possible to talk on 4W private line Data storage function Measured data can be stored by the key
Power supplies 4 “AA” size batteries, AC adapter (ACP‐311M) usable Recommended conditions Temperature:0~40℃, Humidity:20~85% (No condensation allowed) Dimensions & Weight D90×H32×W195 mm: Ignoring protrusion (s) Approx. 450g (batteries not included) ・External power unit
WARNING
Operation with external power unit, the designated AC adapter (ACP‐311M) must be used.
Other adapter may damage the internal power supply, may cause fire, electric shock or failure.
Optional Parts
Standard Parts
・Level Meter
・Cord
・Tester probe
・Handset
・Case
・Dry battery
・OP. Manual
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
PWT‐121 (M1PS alligator clip 1m) ・・・・・・
PWT‐290 (Red/Black 50cm) ・・・・・・・
HS‐107 ・・・・・・・・・・・・・・・・・・・・・・・・・・
PC‐972 ・・・・・・・・・・・・・・・・・・・・・・・・・・・
“AA” size battery ・・・・・・・・・・・・・・・・・・・
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
1
2
1 pair
1
1
4
1
・AC adapter
・Soft case
・Hard case
・Cord for Measurements
・Retardation coil unit
ACP‐311M
PC‐800
PC‐916
PWT‐101
PWT‐103
PWT‐113
PWT‐123
PWT‐311
PWT‐313
RC‐101
:M1P-M1P, 1m
:M1P-M1P, 2m
:M1PS-I214APS, 2m
:M1PS-alligator clip, 2m
:M1PS-M1PS, 1m
:M1PS-M1PS, 2m
Specifications are subject to change without notice.