Matrix Accessories
Bid-Spec
1.0 Description
Alarm Responder for matrix switcher/controller systems.
2.0 Performance Specifications
The alarm responder must be capable of simultaneously providing a relay output associated
with a matrix switcher/controller system’s video output that is currently displaying an alarmed
video input. The alarm responder shall provide 32 addressable Form-A relays, which can be
grouped in series or in two independent groups of 16.
The alarm responder must provide a means for setting one of up to 128 video outputs on the
system to “follow” for each group. The range of each relay group shall be selective in
increments of 16 for up to 128. Access to internal switches or jumpers shall not be required to
accomplish these.
The alarm responder shall provide a common set of input and output connections for each relay
group. The common input connections shall be used to connect a user-supplied voltage,
ground, and other unique input device or for cascading from another group or alarm responder.
The common output connections shall be used to cascade to an additional group or alarm
responder. Relay outputs shall be used to connect to a signal responding device, such as an
indicator light or LED. For ease of connection, all connectors shall be removable “euro-style”
screw-terminal strips.
The input to the alarm responder shall be provided by any one of a variety of matrix
switcher/controller systems and be either a 125 kbps high-speed data or an AD Manchester
control code output. For ease-of-connection, a looping pair of BNC connectors shall be
provided for the high-speed data line and a removable “euro-style” terminal strip for the AD
Manchester control code line.
The unit shall be of a universal mount design providing provisions for rack mounting in
standard 19-inch EIA racks or mounting to a wall, ceiling, or other surface. For ease of
installation and troubleshooting, visual indicators are required for confirmation of power and
control code.
The alarm responder shall be an American Dynamics AD2032 (120 VAC), ADS2032X (230
VAC) or equivalent.
AD2032 v1.0 3610-0223-12
Matrix Accessories
Page 1 of 3
Architect & Engineer Specification
Matrix Accessories
Quick-Spec
3.0 Minimum Performance Specifications
The alarm responder must meet the following operating requirements:
Operational
Common Inputs:............................... Connection to user-supplied voltage, ground, and
other unique input device or for cascading from
another group or alarm responder
Common Outputs: ............................ For cascading to an additional group or alarm
responder
Relay Outputs: ................................. 2 groups of 16 outputs—each group individually set
for a specific output range (1 to 128)
Connections
Commons: ........................................ One removable “euro-style” terminal strip for IN
and OUT
Relay Outputs: ................................. 32 total, four outputs per removable “euro-style”
terminal strip
High Speed Data Line:..................... In (BNC)/Out (BNC)
Manchester Control Code: ............... Removable “euro-style” terminal strip for black,
white and shield connection
Electrical
Supply Voltage:
AD2032: .................................... 120 VAC (50/60 Hz)
ADS2032X: ............................... 230 VAC (50/60 Hz)
Power Requirements: ....................... 8 watts (nominal)
Mechanical
Mounting: ........................................ Universal wall, surface, and rack mount (19-inch
EIA)
Dimensions (H × W × D): ............... 89 × 483 × 203 mm (3.5 × 19 × 8 in)
Weight: ............................................ 3.2 kg (7 lbs.)
Environmental
Operating Temperature: ................... 0–40 °C (32–104 °F)
Relative Humidity: ........................... 98% (non-condensing)
AD2032 v1.0 3610-0223-12
Matrix Accessories
Page 2 of 3
Architect & Engineer Specification
Matrix Accessories
Quick-Spec (continued)
Regulatory
Emissions:
AD2032: .................................... FCC Part 15, subpart B, Class A
ADS2032X: ............................... FCC Part 15, subpart B, Class A;
EN55022 Class B (CE)
Immunity:
ADS2032X: ............................... EN50082-1
Safety:
AD2032: .................................... UL2044
ADS2032X: ............................... EN60950
AD2032 v1.0 3610-0223-12