Primary switch mode power supplies
CP range
Overview
2CDC 275 002 F0b06
4
Special features of CP range primary switch power supplies
Primary switch mode power supplies
High efficiency of approx. 90 %
Low power dissipation and low heating
Long lifetime
Open-circuit, overload and short-circuit proof
Integrated input fuse
Wide range of AC or DC supply voltages
World wide use also in high fluctuating networks and
battery-powered plants
Safety
Closed construction
Touch-proof connecting terminals
Electrical isolation
Constant or adjustable output voltage
(depending on type)
Easy and fast mounting
Mounting on DIN rail
Use in very harsh industrial environments
Reliable construction
According to EMC Directives
EN 61000-6-2 (Interference immunity) and
EN 61000-6-4 (Interference emission)
LED(s) for status indication
Example of application
Supply of programmable logic controllers (PLC)
e. g. AC31, AC500
www.klinkmann.com
www
Primary switch mode power supplies
CP range
Selection table
20 A
5A
10 A
CP-C
20 A
10 A
5A
20 A
5A
CP-S
10 A
40 A
20 A
5A
10 A
20 A
5A
CP-T
10 A
3A
2.5 A
1.25 A
0.75 A
4.2 A
0.625 A
CP-E
2.5 A
2.1 A
1.3 A
Rated output current
0.83 A
0.42 A
CP-D
5 V DC
Rated
output
voltage
12 V DC
24 V DC
48 V DC
12 V DC
10 W
24 V DC
15 W
5 V DC
18 W
24 V DC
12 V DC
30 W
24 V DC
48 V DC
Rated
output
power /
voltage
24 V DC
60 W
48 V DC
100 W
4
24 V DC
12 V DC
120 W
24 V DC
24 V DC
240 W
48 V DC
24 V DC
480 W
48 V DC
24 V DC
960 W
48 V DC
100-240 V AC
115 / 230 V AC auto select
1)
115-230 V AC
2)
Rated
input
voltage
110-240 V AC
110-120 V AC /
220-240 V AC
400-500 V AC
Redundancy unit
Control module
Accessories
Messaging module
Structure of the type designation
1)
2)
CP-x y/z.z
CP: Power supply
x: Product range
y: Rated output voltage
z: Rated output current
CP-E 12/10.0 and CP-E 24/10.0
CP-E 48/10.0
4/3
www.klinkmann.com
www
2CDC110004C0207
Primary switch mode power supplies
CP range
Approvals and marks
existing
pending
H
UL 60950, CAN/CSA C22.2 No.60950
D
GOST
E
CCC
CP-D 24/4.2
UL 1310, CAN/CSA C22.2 No.223
(Class 2 Power Supply)
CP-D 24/2.5
H
CP-D 24/1.3
UL 508, CAN/CSA C22.2 No.14
CP-D 24/0.42
A
CP-D 12/2.1
Approvals
CP-D 12/0.83
CP-D
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
Marks
CE
b
C-Tick
existing
pending
CP-E 24/2.5
CP-E 24/5.0
CP-E 24/10.0
CP-E 24/20.0
CP-E 48/0.62
CP-E 48/1.25
CP-E 48/5.0
CP-E 48/10.0
CP-T 24/5.0
CP-T 24/10.0
CP-T 24/20.0
CP-T 24/40.0
CP-T 48/5.0
CP-T 48/10.0
CP-T 48/20.0
H
CP-E 24/1.25
H
UL 508, CAN/CSA C22.2 No.14
CP-E 24/0.75
A
CP-E 12/10.0
4
CP-E 12/2.5
Approvals
CP-T
CP-E 5/3.0
CP-E
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
CP-RUD
a
UL 1310, CAN/CSA C22.2 No.223
(Class 2 Power Supply)
ANSI/ISA-12.12
(Class I, Div. 2, hazardous locations)
CAN/CSA C22.2 No. 213
H
UL 60950, CAN/CSA C22.2 No.60950
D
GOST
E
CCC
Marks
UL 508, CAN/CSA C22.2 No.14
H
UL 508, CAN/CSA C22.2 No.14
A
H
UL 60950, CAN/CSA C22.2 No.60950
GOST
K
CB scheme
E
CCC
1)
1)
1)
1)
CP-A CM
1)
CP-A RU
1)
CP-A
1)
UL 1604 (Class I, Div. 2, hazardous locations),
CAN/CSA C22.2 No.213
D
CP-C 24/20.0
A
CP-C 24/10.0
Approvals
CP-C
CP-C 24/5.0
CP-S
CP-C MM
existing
pending
CP-S 24/20.0
C-Tick
CP-S 24/10.0
CE
b
CP-S 24/5.0
a
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
1)
Marks
1)
a
CE
b
C-Tick
Approvals refer to the rated input voltage Uin.
ABB_Electronic_Products_and_Relays_CP_Overview_en_1111.pdf
Helsinki
St. Petersburg
Moscow
tel. +358 9 540 4940
automation@klinkmann.fi
tel. +7 812 327 3752
[email protected]
tel. +7 495 641 1616
[email protected]
Yekaterinburg
Samara
Кiev
tel. +7 343 376 5393
[email protected]
tel. +7 846 273 95 85
[email protected]
tel. +38 044 495 33 40
[email protected]
Riga
Vilnius
Tallinn
Мinsk
tel. +371 6738 1617
[email protected]
tel. +370 5 215 1646
[email protected]
tel. +372 668 4500
[email protected]
tel. +375 17 200 0876
[email protected]
www.klinkmann.com
Related documents