The World Leader in High Performance Signal Processing Solutions Medical Applications Electrocardiogram (ECG) Glossary of Terms AED EKG/ECG Holter Monitor Defibrillation T-wave alterans Right Leg Drive RFI ESD 2 Automated External Defibrillator – Auto diagnosis with voice directed treatment. ElectroCardioGram – skin surface, heart monitor Portable device for continuously monitoring the electrical activity of the heart for at least 24 hours. Can be external or implantable. Delivering a therapeutic dose of electrical energy to the heart. A change in the shape of the heartbeat signal on an every other beat basis that is not apparent to the naked eye. An operational amplifier deriving common mode voltage is used to invert the common-mode signal and drive it back into the patient through the right leg. Radio Frequency Interference Electro Static Discharge ECG Markets ECG Professional Healthcare Consumer battery line line battery AED Commercial Fitness Equipment Above Diagnostic Defibrillators Diagnostic 3 Holter Monitor Home Products ECG Waveform (Filtered) 4 ECG – Waveform Characteristics ECG Signals have two components: ECG Waveform 0.05 Hz to 150 Hz bandwidth per Medical Standards Average R Wave Amplitude is 1.8mV Some waveforms can be as big as 10 mV p-p. T wave Alterans are only a few microvolts in amplitude Pacing ArtifactS Medical Standards require 2mV and 200µs detection Average pulse is 1 mV and 500µs but can be much smaller 5 ECG – Patient Skin Surface Characteristics Skin Impedance Standards require of common mode rejection at 51K ohms skin to electrode impedance at 10Hz Good Silver-Silver Chloride electrodes yield about 10 K ohm electrode to skin impedance Stainless Steel electrodes can yield skin impedances of several meg-ohms Defibrillation 5000 DC Voltage volts, 360 Joules Voltage Medical Standards require being capable of acquiring ECG with 300 mV of DC. Mostly due to half cell potential of electrodes, stainless steel can yield 500 mV of DC 60 Hz Noise Average 6 is several mV The World Leader in High Performance Signal Processing Solutions Signal Chains Diagnostic ECG (Clinical Use) 8 Diagnostic ECG In-amp + Right Leg Drive Instrumentation Amplifier G=14 A B 15kΩ +5V 2.2pF 10kΩ 10pF 10kΩ 2.2pF +5V 4.7μF 24.9kΩ -5V +5V24.9kΩ AD8220 220p F 4.12kΩ -5V -5V +5V From Lead I OP2177 C -5V op amps 68pF 866kΩ 499kΩ +5V OP2177 -5V 9 12.7kΩ switch ADG601 REF/2 From Lead II From Lead III 12.7kΩ ADG620 866kΩ Diagnostic ECG Filters + Pace Detection High PassFilter 0.033Hz Low Pass 5th Order Filter at 157Hz G=50 1.18kΩ 57.6kΩ 14kΩ 14kΩ 19.3kΩ 14.5kΩ 33nF 68nF REF/2 47nF +5V +5V 4.7μF 19.3kΩ +5V AD8618 AD8618 14.5kΩ +5V AD8618 AD8618 10nF 220p F switch ADG601 1MΩ 1.15kΩ 33nF REF/2 From Lead II From Lead III REF/2 12.7kΩ ADG620 866kΩ Lead Detection 50kHz 10 22nF 4.99kΩ REF/2 Pacing Artifact Detection Circuitry 33Ω REF/2 Diagnostic ECG ADC + Isolation + Processing 11 Low Power, Low Cost, Wireless ECG (Holter Monitor) 108pF AD623 RA Electrode RL Electrode G=10.6 499kΩ 12 AD8641 681kΩ ESD Defib Protect AD8603 5.23kΩ 10kΩ Anti-aliasFilter -3dB, 1592 Hz G = 22.05 0.47μF ESD Defibrillation Protection 5.23kΩ 5pF RL Electrode 475Ω High-PassPole 0.5Hz ADuC7022 Additional Digital Filter Level Shift Anti-Alias Total Gain ~ 220 ADF702x* Dependent on Frequency Band Used (WMTS or ISM) Low Cost, Low Power AED Single pole anti-alias filter Patient Pads Digital Filtering LCD Display ADR365 AD8220/4 AD8606 Filter and Protection Network AD7685 ADuC70xx or Blackfin® Blanking AD8605 High Voltage Discharge 13 Power Control ADP1712 Li Ion Battery Exercise Heart Rate Monitor (Example: treadmill with heart rate monitor) +5V 40 Hz Low PassFilter Input Protection AD8553 AD8692 AD8692 REF REF REF AD8691 REF High PassFilter 14 ADuC70xx