Download SYS03510 - AE Light

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
AUERSWALD SYSTEMS GmbH
SYS03510
Description:
PRODUCT INFORMATION
Electronic Ballast with Igniter 35 W / 50 W
Electronic ballast with integrated igniter for D2 style lamp types.
Proprietary system intended for customized applications.
Technical Specifications*:
Input Voltage UB:
Nom. 13.2 V, 10 - 16 V DC intended for battery supply
Ratings:
Min. turn-on voltage: 10.0 V +/- 0.8 V
Min. turn-off voltage: 8.0 V +/- 1 V
Max. input voltage: 16.8 V
Input Current IE:
Nom. 3.0 A (UE = 13.2 V / PL = 35 W)
Nom. 4.3 A (UE = 13.2 V / PL = 50 W)
< 6.8 A during start-up, < 10 µA standby
Operating Temperature:
-20 °C to 105 °C, decreasing life time at higher
temperatures, > 5000 h at 105 °C
Efficiency:
Approx. 89 % +/- 2 %, depending on lamp voltage, power and input voltage. > 85 % at 50 W operation
5/8/2017
582770581
Page 1 of 5
AUERSWALD SYSTEMS GmbH
PRODUCT INFORMATION
Cooling:
Requirements for additional heat sink or cooling
depend on final application
Mechanical, Dimensions:
Cylindrical aluminum housing AlMgSi1,
64 mm diameter x 48 mm length, including igniter
Weight:
Approx. 230 g / 8.1 oz
Lamp Control:
Constant power regulation with max. run-up current limit
Power Output PL:
35 W / 50 W depending on control input J3 – J4
Power decreasing with decreasing supply voltage
Output Power Ripple:
< 3 % at 35 W operation
Ignition:
Internal igniter IG035G05 with integrated lamp socket,
"instant" / hot restrike capability
Ignition Time Limit:
Max. 1.2 seconds
Protection:
Thermal turn-off, turn-off if lamp voltage > 150 V or lamp
fails to ignite - restart possible after cooling down and
disconnecting supply or control input for > 5 seconds
Integrated Lamp Socket for P32-d Base:
5/8/2017
582770581
Page 2 of 5
AUERSWALD SYSTEMS GmbH
Location of Input / Output Terminals:
5/8/2017
PRODUCT INFORMATION
582770581
Page 3 of 5
AUERSWALD SYSTEMS GmbH
Input/Output:
PRODUCT INFORMATION
Solder pad terminals
J1:
J2:
JP1:
+BAT, positive supply input
-BAT, negative supply input / GND
ON/OFF control switch,
ON if shortened or applied to +BAT
J3-J4: DIM input, 35W output with resistor 56 Ohm
Wiring option -W1:
UL / AWM style 1007/1569, 105 °C, 200 mm length
Wire color identification:
J1:
J2:
JP1:
Output Connector:
+ UE, AWG20, RED
- UE/GND, AWG20, BLACK
+ ON/OFF input, AWG24, RED
Integrated socket for P32-d lamp base
CAUTION!
Short-circuit and reverse polarity protection with external input fuse 8 A F must
be secured within the final application.
An additional voltage suppressor close to the ballast input behind the fuse is
necessary in case of longer input wiring distances.
DANGER! HIGH VOLTAGE!
This device generates potentially dangerous voltages during operation.
Voltages up to 24,000 V can be present in certain sections of the unit.
Death or serious injury may result if personnel fail to observe safety
precautions. Do not touch open PCB side or lamp socket when power is
applied. Do not apply supply without properly inserted lamp. Make sure that
input supply is disconnected before handling the device.
Further information available from:
AE Light
P.O. Box 1869
Rogue River, OR 97537
Phone: 01-541-471-8988
Fax:
01-541-471-8988
Email: [email protected]
5/8/2017
582770581
Page 4 of 5
AUERSWALD SYSTEMS GmbH
PRODUCT INFORMATION
* At 23 °C +/- 5 °C during normal operation unless otherwise specified. Technical modifications subject to change without notice!
5/8/2017
582770581
Page 5 of 5
Related documents