Appendix B - NI ELVIS Specifications Analyzers Capacitance Oscilloscope Accuracy 0.02 Two channels Range 50 pF to 500 µF Data storage, cursors, auto scaling Test voltage range 1V p-p Max input bandwidth 50 kHz* Continuity Max sampling rate 500 kHz / channel* Resistance threshold Range ±10 V Inductance Input resolution 12 or 16 bits 15 Ω max Accuracy 0.01 Bode Analyzer Range 100 µH to 100 mH Frequency and phase plots Test frequency 950 Hz Frequency range and step control Test frequency voltage 1 V p-p Logarithmic or linear frequency spacing Source Data storage, cursors, auto scaling Function Generator 5 Hz – 35 kHz* Manual or software control Input range ±10 V Sine, triangle, square waveforms Frequency sweep Input resolution 12 or 16 bits TTL sync pulse out Frequency range Dynamic Signal Analyzer Impedance Analyzer Measurement frequency range AM, FM modulation 5 Hz to 35 kHz Two Wire Current Voltage Analyzer Frequency range 5 Hz to 250 kHz Frequency accuracy 0.03 Voltage range ±10 V Output amplitude ±2.5 V Current range ±10 mA Software amplitude resolution 8 bits Three Wire Current Voltage Analyzer Offset range ±5 V NPN BJT transistor only AM voltage 10 V max Data storage, cursors, auto scaling Amplitude modulation Up to 100% 10 V max Maximum Collector Voltage 10 V FM Voltage Minimum base increment 15 µA Amplitude flatness Digital Multimeter Resistance To 50 kHz 0.5 dB To 250 kHz 3 dB Accuracy 0.01 Range 5 Ω to 3 MΩ Arbitrary Waveform Generator Two channels Accuracy 0.003 One-shot or continuous generation Waveform editor Range ±20 V Amplitude ±10 V Input impedance 1MΩ Frequency range DC – 100 kHz * Output drive current 25 mA max DC Voltage AC Voltage Accuracy 0.003 Output impedance: 1 Range ±14 Vmrs Slew rate: 1.5V/µs Current DC accuracy 0.25% ±3 mA** AC accuracy 0.25% ±3 mA** Range ±250 mA Shunt resistance 0.5 Ω Maximum common mode voltage ±20 V Common mode rejection 70 dB 28 Power Supplies ±15 V Supply Output current Fused at 500 mA Ripple and noise 0.01 Line regulation 0.5% max 5 V Supply Output current Fused at 2 A Ripple and noise 0.01 Line regulation 0.5% max Variable power supplies 0 to +12 V and -12 V Ripple and noise 0.0025 Software resolution 7 bits Current limiting 0.5 V at 130 mA, 5 V at 275 mA, 12 V at 450 mA Digital I/O Digital input resolution 8 bits Digital output resolution 8 bits Digital addressing 4 bits * Specification depends on Data Acquisition device functionality ** Proper null correction at the common mode voltage can reduce ±3 mA error to 200 µA Full Data and Spec Sheet for the NI ELVIS System is available at: http://www.ni.com/pdf/products/us/ni_elvis.pdf 29