NANJING AH ELECTRONIC CO., LTD
AH6851 HALL-EFFECT SWITCH INTEGRATED CIRCUITS
These Hall-effect switch integrated circuits are monolithic integrated circuit consisting of a voltage regulator,
Hall-voltage generator, differential amplifier, schmitt trigger, temperature compensation circuit and open-collector
output stage. Its input is a magnetic flux density signal and output is a digital voltage signal.
FEATURES
TYPICAL APPLICATIONS
. Wide supply voltage range
. Contactless switch
. Position control
. Fast response time
. Speed measurement
. Revolution detection
. Wide frequency and temperature range
. Isolation measurement
. Long operating life
. Brushless DC motor
. Automotive ignitor
. Small size, convenient installing
. Output compatible with all digital logic families
ABSOLUTE MAXIMUM RATING
Parameter
Symbol
Value
Unit
Supply voltage
VCC
24
V
Magnetic flux density
B
Output OFF voltage
Vce
50
V
Continuous output current
IOL
50
mA
Operating temperature range
TA
-40~125
℃
Storage temperature range
TS
-55~150
℃
Unlimited
ELECTRICAL CHARACTERISTICS
mT
TA=25℃
Type and Value
Parameter
Symbol
Test conditions
Unit
min
typ
max
4.5
-
24
V
Supply voltage
VCC
Output saturation voltage
VOL
Iout=20mA B>BOP
-
200
400
mV
Output leakage current
IOH
Vout=24V B<BRP
-
0.1
10
μA
Supply current
ICC
VCC=Output open
-
-
10
mA
Output rise time
tr
RL=820Ω CL=20PF
-
0.12
-
μS
Output fall time
tf
RL=820Ω CL=20PF
-
0.18
-
μS
1
AH6851 HALL SWITCH
HALL SENSORS
MAGNET CHARACTERISTICS
VCC=4.5~24V
Type and Value
Parameter
Symbol
Unit
min
typ
Operate point
BOP
Release point
BRP
-10.0
Hysteresis
BH
2
max
10.0
mT
mT
-
mT
NOTE: 1mT=10GS
MAGNETIC-ELECTRICAL
TRANSFER CHARACTERISTICS
BLOCK DIAGRAM
1,Vcc
RL
REG
3, Vo
2, GND
DIMENSIONS
( in: mm)
2.0¡ À0.1
1.0
2.26
0.64
Active Area Depth
作用区深度
4.0¡ À0.1
1.34
4.5¡ À0.1
12.7min
2.70
2¡ ã
0.43
0.38
2¡ ã
Branded Surface
标志面
0.38
1
2
3
1.27
2.34
2¡ ã
1. Vcc
2. GND 3. OUTPUT
5¡ ã
TO –92T Package and Active Area
Cautions
1. When install, should as full
as possible decrease the
mechanical stress acting on the
Hall IC, to avoid the influence
of the operate point and
release point.
2. On the premise of ensuring
welding quality, use as possible
as low welding temperature as
short time.
ADD: ROOM 901,CNK INTERNATIONAL MANSION, NO.198, HONG WU ROAD,NANJING, P.R.CHINA
2
AH6851 HALL SWITCH
TEL: 0086-25-84609021
FAX: 0086-25-84670370
WEBSITE: WWW.AHEST.COM
E-MAIL: [email protected]