Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
14 Environmental Conditions for the Opera Flexicom Environmental Conditions for the Opera Flexicom............................... 3 1 Installing and positioning the Opera Flexicom Control Unit ........................................................ 3 Select a location which is: ................................................................................................................ 3 2 Installing and positioning the Battery Back-Up module ............................................................... 3 Select a location which is: ................................................................................................................ 3 3 Port Properties .............................................................................................................................. 4 4 Dimensions of the Opera Flexicom .............................................................................................. 5 5 Dimensions of Battery Back-up module ....................................................................................... 5 Depth: 80 mm .................................................................................................................... 5 6 Operating Voltage ........................................................................................................................ 5 Mains voltage 230 10% ................................................................................................................. 5 Max power consumption 66 W ......................................................................................................... 5 7 Environmental Specification ........................................................................................................ 5 Operating temperature -5C to + 45C .................................................................................................. 5 8 Space requirements ....................................................................................................................... 6 9 Headset Compatibility on theOperafone Executive Telephone Set .............................................. 7 10 Compatibility of some analogue phones with MDS Opera Flexicom PABX ........................... 8 Environmental Conditions for the Opera Flexicom The control unit is comprised of three printed circuit boards (PCBs) housed in a 3-part plastic enclosure. The enclosure consists of an access cover, a top cover and a base. Six slots in the top cover allow line, extension and applications modules to be added. The access cover encloses the connection area on which the wiring is terminated. 1 Installing and positioning the Opera Flexicom Control Unit Select a location which is: 2 Approximately one metre from the ground for ease of installation Easily accessible and well-lit to enable the wiring of the system Isolated from plumbing and electrical wiring Spacious enough to allow 300mm clearance around the system Not exposed to electromagnetic radiation e.g. lift machinery, arc welders etc. Within 2 metres of a dedicated electrical power point Within convenient reach of the NTU (ISDN line socket) or incoming PSTN wiring Not exposed to extremes of temperature, humidity, dust, damp or direct sunlight. Installing and positioning the Battery Back-Up module Select a location which is: Not exposed to extremes of temperature, humidity, dust, damp or direct sunlight. Spacious enough to allow 150mm clearance around the casing Within 2 metres of the Opera Flexicom Observe anti-static precautions Power down the system Remove the control unit main cover Mount the daughter card on the 4 mounting pillars above the power supply ensuring that the pins of the 12 way connector line up If required, wall-mount the external battery enclosure using the template supplied Terminate the interconnecting cable (system end first) Replace covers Power up the system Check operation with and without mains power. The battery will last up to one hour depending on traffic When adding or removing the encapsulated cards (e.g. line/extension) to the Opera Flexicom, the system MUST be powered down. If a battery back up module is connected to the system this too MUST be disconnected. 3 Port Properties When wiring extensions with 0.5mm copper conductor cable the following limits should be adhered to: 100 ohms or 600m for Operafone Executive and single line display feature sets 504 ohms or 3 km for standard analogue two-wire sets 1,200 ohms or 7 km for analogue extensions programmed to be long-line extensions Note: Any external wiring should have supplementary protection where deemed appropriate. This can be provided using, for example, the following items 100000177 Oneac Kit 6089-1-810-00 Strip Connection 237A 6526-1-022-00 Krone Connection Box 50A Additional line protectors and appropriate strips may be needed depending on the size of the installation 2 x Relays, normally open contacts, max. Current 1 Amp Music on Hold, external source Phono socket input impedance 600 Ohms Max input voltage 4 volts pk-pk Paging Phono socket input impedance 600 Ohms Max output voltage 4 volts pk-pk The Opera Flexicom is supplied with a protective earth connected. No additional external earth connection is necessary. There is a "Protective Bonding Conductor" (Earth Strap) internally in the system. At one end, it connects to the terminal on the MDF, which is labelled “PE”, and at the other end, it is connected to the third (Earth) terminal of the Mains connector in the PSU. It is a length of Green-and-Yellow insulated wire of the same thickness and type as the Earth wire in the three-core mains cable (to which it connects at the mains terminal). Fuse 1,6 Amp 250 Volt HBC (5mm x 20mm) 4 Dimensions of the Opera Flexicom Height: Width: Depth: Depth: Weight of CCU without expansion modules 5 Dimensions of Battery Back-up module 12 Volt Lead Acid 6Ah Height: Depth: Width: Weight: 6 132 mm 80 mm 187 mm 2 Kg (including battery) Operating Voltage Mains voltage Max power consumption 7 367 mm 425 mm 87 mm (without expansion modules) 152 mm (with expansion modules) 3.163 Kg 230 10% 66 W Environmental Specification Operating temperature Humidity Maximum AC V/A: Maximum input watts: Maximum input current at 230Vac: Maximum input current at 180Vac: Power Factor: Extreme working conditions Storage temperature Storage humidity -5C to + 45C 10% to 90% non-condensing 120VA 66W 0.52A 0.67A 0.55 -15C to + 55C -20%C to + 70%C 10% to 90% non-condensing 8 Space requirements The space requirements are outlined below 9 Headset Compatibility on theOperafone Executive Telephone Set The full range of Plantronics ‘H’ Top Headsets will work on the Operafone Executive Telephone Set. The headset will plug directly into the headset port using a Vista to QD (Quick Disconnect) Cable. Details are below for your information. Product Range Part Code Description Operafone Cable 26716-01 Vista Headset to QD (Quick Disconnect) 32184-04 32186-04 33647-01 33693-01 33645-41 33699-41 33646-11 33705-11 36363-01 H51 Headset (One Ear + Headband) H51N Noise Cancelling Headset (One Ear + Headband) H81 Tristar Headset (Over One Ear) H81N Noise Cancelling Tristar Headset (One Over Ear) H91 Headset (One Ear + Headband + Treble / Bass Control) H91N Noise Cancelling Headset (1 Ear + Headband + Treble/Bass Control H101 Headset (Two Ear + Headband + Treble / Bass Control) H101N Noise Cancelling Headset (Two Ear + Headband + Treble / Bass Control) Supra Tristar Encore DuoPro 36366-01 36568-01 DuoPro H171 Combo Headset (One Ear+Headband & Over Ear) DuoPro H171N Noise Cancelling Combo Headset (One Ear+Headband & Over Ear) DuoPro H181 Headset (Behind the Head) 10 Compatibility of some analogue phones with MDS Opera Flexicom PABX Last Number Redial Time Break Recall (transfer, etc) Rings with a different Internal and External Ring Cadence Message Waiting audible indication Message Waiting visual indication Caller Display (CLI) Programmable keys can be Programmed as MDS PABX function keys ULYTEL II PHONE WITH MESSAGE WAITING SIEMENS EUROSET 2010 SIEMENS EUROSET 2015 SIEMENS GIGASET 4010 CLASSIC SIEMENS 4012 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No * Yes No* Yes Yes Yes Yes Yes Yes No Not applicabl e No Not applicabl e Yes Yes No Not applicabl e No Yes** Yes Yes N/A N/A SIEMENS 5012 COLOUR SIEMENS GIGASET C 150 SIEMENS 4012 MICRO N/A N/A N/A Yes * Does not differentiate between Internal and External ring cadence. Rings with one cadence only. **It is necessary to insert a Pause after Recall when programming function keys.