Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
SiteRanger™ Internet-based Site Monitoring System Comprehensive Broadband/ Enterprise site monitoring device for Headend’s, Hub Sites Power Quality Retrofit Monitoring 8,16,24 or 32 isolated input channels Smart transducers for power system monitoring Analog measurements such as temperature, generator fuel levels, AC and DC power systemvoltage, current and power, ground current 1. 19”/23” Rack mount housing 2. Internal Circuit board with integrated electronic components. Internal webserver with TCP/IP, SNMP 3. 8,16,24, or 32 contact closure input channels - Normally open or closed. Accepts contact closures from UPS and DC systems, Generators, HVAC units, Fire Suppression, access control and other site devices 4. Input channels fed from remote relay / form-c dry contact closures. Internal opto isolators provide electrical isolation to web server module 5. LED indicators for Alarm and system status, power supply status. Extended feature version has VFD alphanumeric display 6. Flexible and redundant power supply input. Dual A/B -48VDC inputs for redundant DC plant power, 120VAC input 7. Set-screw terminal blocks for reliable compression connections for direct input wiring. 50 Conductor cable connectors and remote 66 block interface for cross-connect to existing site alarm connections provided 8. Compliant with MSO VOIP telemetry alarm requirements for site monitoring. SNMP trap output via internet connections, email, remote internet login webserver. Provides direct SNMP output support for Spectrum enterprise management software as well as generic SNMP for other Network management software systems for Regional/National NOC visibility 9. 120VAC, dual -48VDC inputs. Surge protected, fuse protected. PoE option for SiteRanger remote module powering 10. Extended version provides Integrated annunciator LCD panel including digital site status, webserver configuration, ethernet port status for communications to network infrastructure Available smart transducer system options include AC monitor module for Generator ATS or UPS power parameter monitoring, DC module for -48VDC power system voltage, current, distribution monitoring, Environmental module for HVAC alarm status, high/low temperature, condensate drain alarms. Generator status module for generator alarms, fuel level. Smart transducers are powered via Power over Ethernet (PoE) from main switch via the SiteRanger LAN for reliability and uninterrupted monitoring General Specifications Model # P/N 016-900-10 Configuration SiteRanger Basic -control module: Part # Description Rack mount housing. Accepts Doc# 048–600–00/Nov.01.06 Contact inputs, Smart transducer interface, internal DC/AC power supply. LED interface panel,Rack mount housing P/N 016-905-10 ACM AC power module Monitors single or three phase AC voltage, current, power parameters. . Use for ATS site power monitoring, UPS output monitoring P/N 016-910-10 DCM DC power module Monitors -48VDC rectifier and battery system status. Measures DC voltage, current, distribution circuit breaker trip, battery status, accepts alarm contact outputs from DC power system P/N 016-915-10 EVM Environmental module Monitors HVAC alarm contact outputs, temperature, condensate drain alarm, multiple temperature sensor inputs for zone temperature monitoring P/N 016-920-10 GSM Generator status module Monitors Generator contact closures, fuel level, starting battery voltage P/N 016-925-10 FSM Generator fuel status module Monitors Generator fuel level. (Diesel or propane) 8/16/24/32 contact inputs, interfaces with CSI smart transducer SiteRanger LAN. Ethernet 10/100 Base T jack with LED indicators. 48VDC/120VAC input, internal power supply Non-metallic housing with terminal block connections for AC voltage sense, current transformer input sense, ATS position sensing (generator/commercial power), 5 alarm contact inputs. SiteRanger LAN port. Specify 1,2 or 3 phase, 120V, 240V, 208V, 480V versions. Current transformers available for 100, 200, 400 and 600A systems Non-metallic housing with terminal block connections for DC voltage sense, DC power system contact closure inputs, distribution alarm contact inputs, SiteRanger LAN port. Specify input configuration, current monitoring kit, battery temperature probe kit Non-metallic housing with terminal block connections for 8 HVAC system alarm contact inputs. 4 Temperature sensor inputs, SiteRanger LAN port. Specify number of temperature sensors required (up to 4) Non-metallic housing with terminal block connections for generator output AC voltage/current sense, 8 alarm contact inputs. SiteRanger LAN port. Specify 1,2 or 3 phase. Monitors Generator fuel level. Specify diesel tank level sensor, propane tank transducer head (various Doc# 048–600–00/Nov.01.06 P/N 016-927-10 GNSM Ground network system monitor Multipoint ground current monitoring versions depending upon tank vendor) Monitors ground current / fault current. Supports up to 8 Hall effect or shunt based ground current detector modules Common Specifications for All Models Dimensions: 17" W x 3.75” (2RU) T x 12” D Weight: 10 lbs Rack mount with 19/23” reversable mounting flanges. Hinged cover w/LED or VFD control panel. Unit includes wiring diagram / instruction manual, software, spare fuses Electrical specifications: Input: 120VAC power supply and dual -48VDC redundant inputs. All three power inputs are redundant and will operate the unit. Order Information Shipping box packaging for UPS/FedEx shipment. Typical configuration includes bill of materials/parts kit as per customer site survey order form CSI Provides customer site surveys at no charge to provide customer proposals for the correct SiteRanger component and installation configurations. Doc# 048–600–00/Nov.01.06