Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Measuring Air Changes per Hour with Carbon Dioxide Dr Rod Escombe MRCP DTM&H PhD Honorary Research Fellow, Wellcome Centre for Clinical Tropical Medicine & Department of Infectious Diseases & Immunity, Imperial College London, UK. Senior Investigator, Asociación Benéfica PRISMA, Lima, Perú. GP Registrar, St Mary’s Hospital, London, UK. HOSPITAL NACIONAL “DOS DE MAYO” Measuring room air exchange • Measure air supply & extract • Negative pressure: extract > supply by ~10% Calculating ACH • • • • Q = room ventilation (cfm) V = velocity (feet/min) A = duct area (square feet) ACH = Q/room volume 1 Measuring room air exchange in low resource settings Q=V x A ACH = Q/volume Measuring room air exchange using a tracer gas Principles: • • • • Use gas that is not usually present in the room air: SF6 Deliver gas and mix with room air Measure concentration decay to calculate air exchange US$ 30,000 Also a continuous release methodology Concentration decay 8000 7000 Standard tracer gas technique: 6000 5000 • • • American Standards and Test Material Committee. 1988. Standard test method for determining air leakage rate by tracer dilution. In Annual Book ASTM Standards & Test Materials. Wash DC. 568575 Standard test methods for determining air change in a single zone by means of a tracer gas dilution. Standard E741-00. Philadelphia, Pennsylvania: American Society for Testing Materials. Decker J. Evaluation of isolation rooms in health care settings using tracer gas analysis. Appl Occup Envir Hyg 1995;10:887-91. 4000 3000 2000 1000 0 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 Ti m e Other methods: theatrical fog • Gershey EL, Reiman J, Wood W, Party E. Evaluation of a room for tuberculosis patient isolation using theatrical fog. Infect Control Hosp Epidemiol. 1998 Oct;19(10):760-6. 2 Measuring natural ventilation Measuring room air exchange using carbon dioxide as a tracer gas • Infra-red gas analyser to measure CO2 concentrations • Advatanges: Cheap CO2 easily available (dry ice, fizzy drinks) Can use occupied rooms • Disadvantages: Not perfect CO2 present in air CO2 produced by occupants • Menzies R, Schwartzman K, Loo V, Pasztor J. Measuring ventilation of patient care areas in hospitals. Description of a new protocol. Am J Respir Crit Care Med 1995;152:1992-9. 3 CO2 release Windows opened 6000 CO2 concentration (ppm) 5000 4000 Slow CO2 concentration decay with windows closed 3000 Rapid decay with windows open 0.5 ACH 2000 12 ACH 1000 0 0 5 10 15 20 25 30 35 Time (minutes) Closing apertures 4 CO2 release Small rooms, little ventilation: Gas cylinder Large rooms, lots of ventilation: Fire extinguisher CO2 release Very big rooms – lots of fire extinguishers 5 Mixing: Aiming for complete mixing Mixing no electricity 6 CO2 release Windows opened 6000 CO2 concentration (ppm) 5000 4000 Slow CO2 concentration decay with windows closed 3000 Rapid decay with windows open 0.5 ACH 2000 12 ACH 1000 0 0 5 10 15 20 25 30 35 Time (minutes) Calculation of ACH CO2 release Calculation of ACH Windows opened 6000 ACH = Absolute ventilation / Room Volume =Q/V CO2 concentration (ppm) 5000 4000 3000 Slow CO2 concentration decay with windows closed Rapid decay with windows open 0.5 air-changes/hour 12 air-changes/hour 2000 1000 0 0 5 10 15 20 25 30 35 Time (minutes) Plot natural log of CO2 concentration against time ACH = slope of line of best fit Ln ppm Units: concentration (eg ppm) vs. time in hours Natural log of all data 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0 0.0 0.00 0.20 0.40 0.60 0.80 hours from start of experiment 7 CO2 release Windows opened 6000 Calculation of ACH CO2 concentration (ppm) 5000 4000 3000 Slow CO2 concentration decay with windows closed Rapid decay with windows open 0.5 air-changes/hour 12 air-changes/hour 2000 Natural logarithm CO2 concentration (ppm) 1000 0 Windows and doors CLOSED 0.5 ACH 0 5 10 15 20 25 30 35 Time (minutes) 8.7 y = -0.50x + 8.70 2 R = 0.89 8.6 8.5 0.00 0.05 0.10 0.15 0.20 0.25 0.30 0.35 Time (hours) CO2 release Windows opened 6000 Calculation of ACH CO2 concentration (ppm) 5000 4000 3000 Slow CO2 concentration decay with windows closed Rapid decay with windows open 0.5 air-changes/hour 12 air-changes/hour 2000 1000 0 0 5 10 15 20 25 30 35 Natural logarithm CO2 concentration (ppm) Time (minutes) 9 Windows and doors OPEN 12 ACH 8 7 6 5 4 y = -12.25x + 12.10 R2 = 0.88 3 2 1 0 0.30 0.35 0.40 0.45 0.50 Time (hours) 8 Where to stop? • Depends on room occupants • Within 200 ppm of baseline CO2 release Windows opened 6000 CO2 concentration (ppm) 5000 4000 3000 Slow CO2 concentration decay with windows closed Rapid decay with windows open 0.5 air-changes/hour 12 air-changes/hour 2000 1000 0 0 5 10 15 20 25 30 35 Time (minutes) ACH vs. Absolute ventilation Concentration (cfu/m3) 100 ACH = Q / V Q = ACH x V 80 60 4m V= 4x25 = 100 m3 12 ACH = 1,200 m3/h 2m V = 2x25 = 50 m3 12 ACH = 600 m3/h 40 20 1 ACH 0 0 1 8 2 4 2 3 4 Area 25 m3 Time (hours) In models of airborne infection, it is absolute ventilation that is a major determinant of disease transmission Wells-Riley equation: C=S(1-e –Iqpt/Q) 9 Effect of room volume if ACH is constant Wells-Riley equation: C=S(1-e –Iqpt/Q) ACH=12 Q=1,200 C=1x(1-e-1x13x0.6x8)/1,200 =0.05 Risk = 5% ACH=12 Q=600 C=1x(1-e-1x13x0.6x8)/1,200 =0.10 Risk = 10% C= new cases S=susceptibles I =number of infectors q=infectious quanta produced per hour p=pulmonary minute ventilation t=duration of exposure Q=absolute ventilation Mechanical ventilation can’t deliver high ACH in large rooms due to cost, drafts, fan noise etc More complex: room crowding / bed spacing / near-far effect Measuring room air exchange using carbon dioxide as a tracer gas Conclusions • Simple • Easy to do • Equipment relatively easily available • Cheap • A bit rough, but with inherent variability of natural ventilation (wind speed etc) and such high air exchange rates, high precision is less important • It’s fun! 10 Thank you 11