Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
H07RN-F Industrial flexible cable, insulation and outer sheath in elastomer Description Application H07RN-F flexible cable is intended for installations with moving equipment, electric appliances and for building sites. The cable may be rated 0,6/1 kV where the installation has built-in protection and for motors in lifting appliances - machine tools - etc. This cable can be used in refrigerating installations. Installation This cable can be installed in open air or be buried but with extra mechanical protection. Conductors laid up Assembled conductors. Marking USE <HAR> N (x ou G) S • N = number of cores • G = with Green-Yellow • x = without Green-Yellow • S = section in mm² Nota Max continuous operating conductor temperature in normal use : Standards International HD 22.4; HD 516; IEC 60245-4 type 66 National NF C 32-102-4 +60°C ( in every case of mobile installation) +85°C ( fixed protected installation ) +200°C ( in short circuit ) Permissible current rating is measured for an ambient temperature of 30°C and a maximum operating and conductor temperature of 85°C . For other temperature please refer to correction factors . Lead free Yes Mechanical resistance to impacts Cable flexibility Chemical resistance Water proof Flexible Accidental Good Very good Generated 4/18/06 - http://www.nexans.fr/e-service/ Operating temperature, range -25 .. 55 °C Page 1 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. H07RN-F Contact Nexans - Building activity 4-10 rue Mozart 92587 Clichy Cedex France [email protected] Lead free Yes Mechanical resistance to impacts Cable flexibility Chemical resistance Water proof Flexible Accidental Good Very good Generated 4/18/06 - http://www.nexans.fr/e-service/ Operating temperature, range -25 .. 55 °C Page 2 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. H07RN-F Characteristics Construction characteristics Outer sheath Sheath colour Insulation Lead free Mechanical characteristics Mechanical resistance to impacts Cable flexibility Usage characteristics Chemical resistance Water proof Short-circuit maximum core temperature Operating temperature, range Maximum core temperature still Special cross-linked elastomer Black Special cross-linked elastomer Yes Very good Flexible Accidental Good 200 °C -25 .. 55 °C 60 °C New cores identification Core identification in accordance with HD 308 S2 (October 2001)Identification of cores in cables and flexible cords. Number of cores HD 308 S2 since january 2004 G (earth core) X (without earth core) 1 Black (preferential) Black (preferential) 2 Blue + Brown Blue + Brown 3* Green - Yellow + Blue + Brown Brown + Black + Grey 3** Blue + Brown + Black 4 Green - Yellow + Brown + Black + Grey Blue + Brown + Black + Grey 5 Green - Yellow + Blue + Brown + Black + Grey Blue + Brown + Black + Grey + Black > 5 White printed numbers + 1 Green - Yellow White printed numbers * For the cables without Green/Yellow with a cross-section >4mm² ** For the cables without Green/Yellow with a cross-section of 1,5mm² & 2,5mm² Single Core Cross section mm² 1.5 2.5 4 6 10 16 Perm. current rating open air A 23 32 43 56 77 102 Voltage drop, single phase V/A.km 23.3 14.0 8.7 5.9 3.4 2.2 Max. outer diam. mm 7.1 7.9 9.0 9.8 11.9 13.4 Approx. weight kg/km 50 66 94 109 182 256 Generated 4/18/06 - http://www.nexans.fr/e-service/ Max. linear resistance, phase conductor Ohm/km 13.3 7.98 4.95 3.3 1.91 1.21 Page 3 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. H07RN-F Cross section mm² 25 35 50 70 120 150 185 240 300 500 Perm. current rating open air A 136 168 203 254 363 416 475 559 637 833 Voltage drop, single phase V/A.km 1.4 1.04 0.75 0.56 0.36 0.31 0.28 0.23 0.2 0.16 Max. outer diam. mm 15.8 17.9 20.6 23.3 28.6 31.4 34.4 38.3 41.9 52.0 Approx. weight kg/km 369 482 662 895 1430 1740 2160 2730 3480 5700 Max. linear resistance, phase conductor Ohm/km 0.78 0.554 0.386 0.272 0.161 0.129 0.106 0.0801 0.0641 0.0384 Two cores Cross section mm² 1 1.5 4 6 10 16 25 Perm. current rating open air A 18 23 43 56 77 102 136 Voltage drop, single phase V/A.km 39.4 27.0 10.1 6.7 3.8 2.5 1.68 Max. outer diam. mm 10.0 11.0 15.1 16.8 22.6 25.7 30.7 Approx. weight kg/km 99 111 238 279 538 744 1074 Max. linear resistance, phase conductor Ohm/km 19.5 13.3 4.95 3.3 1.91 1.21 0.78 Three cores Cross section mm² 1.5 2.5 6 10 16 25 35 50 70 95 120 150 185 240 300 Perm. current rating open air A 23 32 56 77 102 136 168 203 262 320 373 432 495 587 680 Voltage drop, single phase V/A.km 27.0 16.2 7.0 4.0 2.5 1.7 1.21 0.87 0.64 0.5 0.4 0.35 0.3 0.26 0.22 Max. outer diam. mm 11.9 14.0 18.0 24.2 27.6 33.0 37.1 42.9 48.3 54.0 60.0 66.0 72.0 82.0 90.0 Approx. weight kg/km 134 195 346 663 924 1345 1760 2390 3110 4170 5080 6220 7730 9780 12620 Max. linear resistance, phase conductor Ohm/km 13.3 7.98 3.3 1.91 1.21 0.78 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0.08 0.064 Generated 4/18/06 - http://www.nexans.fr/e-service/ Page 4 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. H07RN-F Four cores Cross section mm² 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 Five cores Cross section mm² 1 1.5 2.5 4 6 10 16 25 35 50 70 95 Twelve cores Cross section mm² 1.5 Perm. current rating open air A 16 21 29 38 50 68 92 122 150 182 232 281 325 373 425 500 Voltage drop, single phase V/A.km 34.08 23.3 14.0 8.71 5.84 3.42 2.2 1.44 1.04 0.75 0.56 0.44 0.36 0.31 0.28 0.23 Max. outer diam. mm 12.0 13.1 15.5 18.0 20.0 26.5 30.1 36.6 41.1 47.5 54.0 61.0 66.0 73.0 80.0 91.0 Approx. weight kg/km 144 165 245 357 443 818 1150 1700 2180 3030 3990 5360 6500 7990 9910 13120 Max. linear resistance, phase conductor Ohm/km 19.5 13.3 7.98 4.95 3.3 1.91 1.21 0.78 0.554 0.386 0.272 0.206 0.161 0.129 0.106 Perm. current rating open air A 16 21 29 38 50 68 92 122 Voltage drop, single phase V/A.km 34.1 23.6 14.0 8.72 5.84 3.43 2.2 1.44 Max. outer diam. mm 14.0 14.4 17.0 19.9 22.2 29.1 33.3 40.4 Approx. weight kg/km 180 238 297 453 557 1001 1430 2096 2716 3809 5087 6637 Max. linear resistance, phase conductor Ohm/km 19.5 13.3 7.98 4.95 3.3 1.91 1.21 0.78 Approx. weight kg/km 510 Max. linear resistance, phase conductor Ohm/km 13.3 Perm. current rating open air A 11 Voltage drop, single phase V/A.km 23.3 Max. outer diam. mm 22.14 Generated 4/18/06 - http://www.nexans.fr/e-service/ 0.386 Page 5 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. H07RN-F Eighteen cores Cross Perm. current section rating open air mm² A 1.5 9 thirty six cores Cross section mm² 1.5 Voltage drop, single phase V/A.km 20.7 Perm. current rating open air A 6 Max. outer diam. mm 26.3 Max. outer diam. mm 35.2 Approx. weight kg/km 730 Approx. weight kg/km 1325 Generated 4/18/06 - http://www.nexans.fr/e-service/ Max. linear resistance, phase conductor Ohm/km 13.3 Max. linear resistance, phase conductor Ohm/km 13.3 Page 6 / 6 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.