H07RN-F
Industrial flexible cable, insulation and outer sheath in elastomer
Description
Application
H07RN-F flexible cable is intended for installations with moving
equipment, electric appliances and for building sites. The cable may be
rated 0,6/1 kV where the installation has built-in protection and for motors
in lifting appliances - machine tools - etc.
This cable can be used in refrigerating installations.
Installation
This cable can be installed in open air or be buried but with extra
mechanical protection.
Conductors laid up
Assembled conductors.
Marking
USE <HAR> N (x ou G) S
• N = number of cores
• G = with Green-Yellow
• x = without Green-Yellow
• S = section in mm²
Nota
Max continuous operating conductor temperature in normal use :
Standards
International HD 22.4; HD
516; IEC 60245-4 type 66
National NF C 32-102-4
+60°C ( in every case of mobile installation)
+85°C ( fixed protected installation )
+200°C ( in short circuit )
Permissible current rating is measured for an ambient temperature of 30°C
and a maximum operating and conductor temperature of 85°C . For other
temperature please refer to correction factors .
Lead free
Yes
Mechanical resistance to
impacts
Cable flexibility
Chemical resistance
Water proof
Flexible
Accidental
Good
Very good
Generated 4/18/06 - http://www.nexans.fr/e-service/
Operating temperature,
range
-25 .. 55 °C
Page 1 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
H07RN-F
Contact
Nexans - Building activity
4-10 rue Mozart
92587 Clichy Cedex
France
[email protected]
Lead free
Yes
Mechanical resistance to
impacts
Cable flexibility
Chemical resistance
Water proof
Flexible
Accidental
Good
Very good
Generated 4/18/06 - http://www.nexans.fr/e-service/
Operating temperature,
range
-25 .. 55 °C
Page 2 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
H07RN-F
Characteristics
Construction characteristics
Outer sheath
Sheath colour
Insulation
Lead free
Mechanical characteristics
Mechanical resistance to impacts
Cable flexibility
Usage characteristics
Chemical resistance
Water proof
Short-circuit maximum core temperature
Operating temperature, range
Maximum core temperature still
Special cross-linked elastomer
Black
Special cross-linked elastomer
Yes
Very good
Flexible
Accidental
Good
200 °C
-25 .. 55 °C
60 °C
New cores identification
Core identification in accordance with HD 308 S2 (October 2001)Identification of cores in cables and flexible
cords.
Number of cores
HD 308 S2 since january 2004
G (earth core)
X (without earth core)
1
Black (preferential)
Black (preferential)
2
Blue + Brown
Blue + Brown
3*
Green - Yellow + Blue + Brown
Brown + Black + Grey
3**
Blue + Brown + Black
4
Green - Yellow + Brown + Black + Grey
Blue + Brown + Black + Grey
5
Green - Yellow + Blue + Brown + Black + Grey Blue + Brown + Black + Grey + Black
> 5
White printed numbers + 1 Green - Yellow
White printed numbers
* For the cables without Green/Yellow with a cross-section >4mm²
** For the cables without Green/Yellow with a cross-section of 1,5mm² & 2,5mm²
Single Core
Cross
section
mm²
1.5
2.5
4
6
10
16
Perm. current
rating open air
A
23
32
43
56
77
102
Voltage drop,
single phase
V/A.km
23.3
14.0
8.7
5.9
3.4
2.2
Max. outer
diam.
mm
7.1
7.9
9.0
9.8
11.9
13.4
Approx.
weight
kg/km
50
66
94
109
182
256
Generated 4/18/06 - http://www.nexans.fr/e-service/
Max. linear resistance,
phase conductor
Ohm/km
13.3
7.98
4.95
3.3
1.91
1.21
Page 3 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
H07RN-F
Cross
section
mm²
25
35
50
70
120
150
185
240
300
500
Perm. current
rating open air
A
136
168
203
254
363
416
475
559
637
833
Voltage drop,
single phase
V/A.km
1.4
1.04
0.75
0.56
0.36
0.31
0.28
0.23
0.2
0.16
Max. outer
diam.
mm
15.8
17.9
20.6
23.3
28.6
31.4
34.4
38.3
41.9
52.0
Approx.
weight
kg/km
369
482
662
895
1430
1740
2160
2730
3480
5700
Max. linear resistance,
phase conductor
Ohm/km
0.78
0.554
0.386
0.272
0.161
0.129
0.106
0.0801
0.0641
0.0384
Two cores
Cross
section
mm²
1
1.5
4
6
10
16
25
Perm. current
rating open air
A
18
23
43
56
77
102
136
Voltage drop,
single phase
V/A.km
39.4
27.0
10.1
6.7
3.8
2.5
1.68
Max. outer
diam.
mm
10.0
11.0
15.1
16.8
22.6
25.7
30.7
Approx.
weight
kg/km
99
111
238
279
538
744
1074
Max. linear resistance,
phase conductor
Ohm/km
19.5
13.3
4.95
3.3
1.91
1.21
0.78
Three cores
Cross
section
mm²
1.5
2.5
6
10
16
25
35
50
70
95
120
150
185
240
300
Perm. current
rating open air
A
23
32
56
77
102
136
168
203
262
320
373
432
495
587
680
Voltage drop,
single phase
V/A.km
27.0
16.2
7.0
4.0
2.5
1.7
1.21
0.87
0.64
0.5
0.4
0.35
0.3
0.26
0.22
Max. outer
diam.
mm
11.9
14.0
18.0
24.2
27.6
33.0
37.1
42.9
48.3
54.0
60.0
66.0
72.0
82.0
90.0
Approx.
weight
kg/km
134
195
346
663
924
1345
1760
2390
3110
4170
5080
6220
7730
9780
12620
Max. linear resistance,
phase conductor
Ohm/km
13.3
7.98
3.3
1.91
1.21
0.78
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.08
0.064
Generated 4/18/06 - http://www.nexans.fr/e-service/
Page 4 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
H07RN-F
Four cores
Cross
section
mm²
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
Five cores
Cross
section
mm²
1
1.5
2.5
4
6
10
16
25
35
50
70
95
Twelve cores
Cross
section
mm²
1.5
Perm. current
rating open air
A
16
21
29
38
50
68
92
122
150
182
232
281
325
373
425
500
Voltage drop,
single phase
V/A.km
34.08
23.3
14.0
8.71
5.84
3.42
2.2
1.44
1.04
0.75
0.56
0.44
0.36
0.31
0.28
0.23
Max. outer
diam.
mm
12.0
13.1
15.5
18.0
20.0
26.5
30.1
36.6
41.1
47.5
54.0
61.0
66.0
73.0
80.0
91.0
Approx.
weight
kg/km
144
165
245
357
443
818
1150
1700
2180
3030
3990
5360
6500
7990
9910
13120
Max. linear resistance,
phase conductor
Ohm/km
19.5
13.3
7.98
4.95
3.3
1.91
1.21
0.78
0.554
0.386
0.272
0.206
0.161
0.129
0.106
Perm. current
rating open air
A
16
21
29
38
50
68
92
122
Voltage drop,
single phase
V/A.km
34.1
23.6
14.0
8.72
5.84
3.43
2.2
1.44
Max. outer
diam.
mm
14.0
14.4
17.0
19.9
22.2
29.1
33.3
40.4
Approx.
weight
kg/km
180
238
297
453
557
1001
1430
2096
2716
3809
5087
6637
Max. linear resistance,
phase conductor
Ohm/km
19.5
13.3
7.98
4.95
3.3
1.91
1.21
0.78
Approx.
weight
kg/km
510
Max. linear resistance,
phase conductor
Ohm/km
13.3
Perm. current
rating open air
A
11
Voltage drop,
single phase
V/A.km
23.3
Max. outer
diam.
mm
22.14
Generated 4/18/06 - http://www.nexans.fr/e-service/
0.386
Page 5 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
H07RN-F
Eighteen cores
Cross
Perm. current
section
rating open air
mm²
A
1.5
9
thirty six cores
Cross
section
mm²
1.5
Voltage drop,
single phase
V/A.km
20.7
Perm. current rating
open air
A
6
Max. outer
diam.
mm
26.3
Max. outer
diam.
mm
35.2
Approx.
weight
kg/km
730
Approx.
weight
kg/km
1325
Generated 4/18/06 - http://www.nexans.fr/e-service/
Max. linear resistance,
phase conductor
Ohm/km
13.3
Max. linear resistance, phase
conductor
Ohm/km
13.3
Page 6 / 6
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans
is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Related documents