Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: BLACK Revision Date: 01/29/01 SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: Part Number: Family: Company: e-STUDIO6CP Toner Cartridge -- Black 15A3106 Contains Toner Toshiba America Business Solutions, Inc. 2 Musick Irvine, CA 92618-163 Emergency Telephone No: 800-424-9300 SECTION 2 - GENERAL COMPOSITION OF TONER CONTAINED IN CARTRIDGE COMPONENT PERCENT (wt.) CAS# OSHA PEL ACGIH TLV Polyester Resin Polypropylene Wax Organic Boron Comp. Carbon Black Amorphous Silica 80-90 0.5-5 0.1-3 3-10 <3 41259-36-3 9003-07-0 114803-11-1 1333-86-4 68909-20-6 (1) (1) (1) 3.5 mg/m3(2) 80 mg/ m3 %SiO2 (1) (1) (1) 3.5 mg/m3(2) 10 mg/ m3 Notes: (1) Specific workplace limits have not been established. (2) Total dust, measured as carbon black. SECTION 3 - HAZARDS IDENTIFICATION The following information is based on data obtained from testing of the product or similar products and on the characteristics of component chemicals: Primary Routes of Entry: Toner is contained in cartridge. Exposure potential includes incidental inhalation of toner dust and possible minimal skin contact during cartridge change. There is no evidence that toner is absorbed through the skin. Signs and Symptoms of Exposure: Toner on skin or mucus membranes (mouth, eyes & nose). Medical Conditions Aggravated by Exposure: None known at intended levels of use. Exposure to high airborne dust concentrations, including toner, may aggravate existing respiratory conditions. Physical Hazards : As with most finely divided dusts, explosion is possible when extremely high concentrations of dust and an ignition source are present. Not a hazard under normal conditions of use. Page 1 of 5 TOSHIBA M ATERIAL SAFETY DATA SHEET e-STUDIO6CP FUSER OIL BOTTLE Revision Date: 02/13/01 SECTION 1 - CHEMICAL PRODUCTS AND COMPANY IDENTIFICATION Name: Part Number: Chemical Family: Product Use: Fuser Oil Bottle 15W0906 Bottle contains dimethylpolysiloxane oil Container of fuser oil for use in Toshiba e-STUDIO6CP printers SECTION 2 - COMPOSITION / INFORMATION ON INGREDIENTS COMPONENT Dimethylpolysiloxane Notes: PERCENT (wt.) 100 CAS# No Hazardous Materials Present OSHA PEL ACGIH TLV (1) (1) Specific work place exposure limits have not been established. SECTION 3 - HAZARDS IDENTIFICATION Primary Routes of Entry: Skin contact. Signs and Symptoms of Exposure: Oily skin. Medical Conditions Aggravated by Exposure: None known at intended levels of use. Physical Hazards: Spills can cause surfaces to be slippery. POTENTIAL HEALTH EFFECTS: Inhalation: Skin Contact: Eye Contact: Short Term Exposure - Long Term Exposure Short Term Exposure - Long Term Exposure - Short Term Exposure - Long Term Exposure - Low vapor pressure, inhalation unlikely unless oil mist inhaled. Exposure not probable with intended use. No adverse chronic effects known. Slight skin irritation possible in sensitive individuals. Significant exposure unlikely with intended use. No adverse chronic effects known. Significant exposure not probable with intended use. Slight, temporary irritation possible as with any oil. No adverse chronic effects known. Significant exposure not probable with intended use. Page 1 of 4 (1) TOSHIBA Ingestion: MATERIAL SAFETY DATA SHEET e-STUDIO6CP FUSER OIL BOTTLE Revision Date: 02/13/01 Short Term Exposure - Swallowing small amounts is not likely to cause harm. Swallowing large amounts may cause digestive discomfort. Exposure not probable with intended use. Long Term Exposure - No adverse chronic effects known. Exposure not probable with intended use. SECTION 4 - FIRST AID MEASURES Inhalation: If symptoms, such as shortness of breath or coughing are experienced, remove source of contamination and move individual to fresh air. If symptoms persist, seek medical attention. Skin Contact: Remove contaminated clothing. Wash affected area with soap and water. Should irritation occur, seek medical attention. Eye Contact: Flush immediately with plenty of water. Remove contact lenses and continue flushing for at least 15 minutes. Seek medical attention if irritation develops and persists. Ingestion: If conscious, stomach contents may be diluted by drinking several glasses of water. To avoid aspiration of oil, do not induce vomiting. Seek medical attention. SECTION 5 - FIRE FIGHTING MEASURES Flash Point: Expected to be > 200 o C (open cup) Autoignition: Not available Extinguishing Media: Water spray or fog, dry chemical, CO2 or foam. Firefighting: NIOSH approved self-contained breathing apparatus may be required if a large amount of fuser oil is involved. Unusual Fire and Explosion Hazard: None Hazardous Combustion Products: Carbon dioxide, carbon monoxide, formaldehyde and unidentified organics. SECTION 6 - ACCIDENTAL RELEASE MEASURES Occupational Spill: Soak up the spill with absorbent material and place in a closed container for disposal. Ensure the spill is completely cleaned up because the residue is slippery. SECTION 7 - HANDLING AND STORAGE Store in a cool location. Keep the lid closed tightly. Do not lay container on its side. 2 TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP FUSER OIL BOTTLE Revision Date: 02/13/01 SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION Exposure Limits: None established Ventilation: Mechanical room ventilation recommended. Eye Protection: Safety glasses with side shields recommended. Protective Clothing: None required for intended use in printer. Gloves: Impervious gloves recommended when handling large quantities of this material. Respirator: None required for intended use in printer. SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES Description: Clear liquid with slight odor Pressurized: No % Volatility: Not applicable pH: Not applicable Vapor Density (Air = 1): Not available Evaporation Rate: Negligible Melting Point: Not available Water Solubility: Negligible o o Boiling Point: > 600 F (315 C) @ 760 mmHg Vapor Pressure: Expected to be < 5 mmHg @ 77 o F (25 o C) Specific Gravity (H2 0 =1): Expected to be approx. 0.97 SECTION 10 - STABILITY AND REACTIVITY Stability: Stable under normal storage conditions Conditions to Avoid: None known Incompatibilities: Oxidizers Hazardous Decomposition: Carbon dioxide, carbon monoxide, silicon dioxide, formaldehyde and other organics. Hazardous Polymerization: This product will not polymerize. SECTION 11 - TOXICOLOGY INFORMATION Acute Toxicity: Dimethylpolysiloxanes are practically biologically inert polymers. LD50 expected to be > 24 g/kg (oral, rat). SECTION 12 - ECOLOGICAL INFORMATION Environmental impact rating (0-4): Not available Acute Aquatic Toxicity: Not available Degradability: Not available Log Bioconcentration Factor (BCF): Not available Log Octanol/Water Partition Coefficient: Not available 3 TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP FUSER OIL BOTTLE Revision Date: 02/13/01 SECTION 13 - WASTE DISPOSAL INFORMATION This product is not a listed or hazardous waste in accordance with Federal Regulation 40 CFR Part 261 or the Code of California Regulations Title 22. If discarded in its purchased form, this product would not be a hazardous waste either by listing or by characteristic. However, under US EPA RCRA, it is the responsibility of the product user to determine at the time of disposal whether a material has been contaminated and should be classified as a hazardous waste. Disposal is subject to local, state and federal regulations. Federal regulations prohibit disposal of liquid waste in municipal solid waste landfills. This material can be mixed with a solid absorbent and then disposed of at a landfill. SECTION 14 - TRANSPORTATION INFORMATION This product is not regulated as a hazardous material by the DOT. SECTION 15 - REGULATORY INFORMATION All ingredients are registered under the Toxic Substances Control Act (TSCA) or under polymer exemption. All ingredients are registered or considered registered (polymers) under European Inventory of Existing Commercial Chemical Substances (EINECS/ELINCS). None of the product ingredients are listed as Emergency Planning and Community Right-toKnow Act (EPCRA) - Section 302: Extremely Hazardous Substances (EHS). None of the product components are present above the minimum quantities of listed chemicals in EPCRA Section 313 Supplier Notification. This product contains no known materials at levels which the State of California has found to cause cancer, birth defects or other reproductive harm - California Proposition 65. SECTION 16 - OTHER Disclaimer: Data are most current known to Toshiba at the time of preparation and are believed to be accurate. No warranty as to their accuracy or completeness is expressed or implied. 4 TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: YELLOW Revision Date: 02/09/01 SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: Part Number: Family: Company: e-STUDIO6CP Toner Cartridge -- Yellow 15A3108 Contains Toner Toshiba America Business Solutions, Inc. 2 Musick Irvine, CA 92618-163 Emergency Telephone No: 800-424-9300 SECTION 2 - GENERAL COMPOSITION OF TONER CONTAINED IN CARTRIDGE COMPONENT PERCENT (wt.) CAS# OSHA PEL ACGIH TLV Polyester Resin Polypropylene Wax Organic Boron Comp. Organic Pigment Amorphous Silica 75-90 4-6 3-5 3-10 <3 (1) 9010-79-1 114803-11-1 4531-49-1 68611-44-9 7631-86-9 (2) (2) (2) (2) 80 mg/ m3 %SiO2 (2) (2) (2) (2) 10 mg/ m3 Notes: (1) Trade secret or patented molecule (NJTSRN 80100252-5001) (2) Specific workplace limits have not been established SECTION 3 - HAZARDS IDENTIFICATION The following information is based on data obtained from testing of the product or similar products and on the characteristics of component chemicals: Primary Routes of Entry: Toner is contained in cartridge. Exposure potential includes incidental inhalation of toner dust and possible minimal skin contact during cartridge change. There is no evidence that toner is absorbed through the skin. Signs and Symptoms of Exposure: Toner on skin or mucus membranes (mouth, eyes & nose). Medical Conditions Aggravated by Exposure: None known at intended levels of use. Exposure to high airborne dust concentrations, including toner, may aggravate existing respiratory conditions. Physical Hazards : As with most finely divided dusts, explosion is possible when extremely high concentrations of dust and an ignition source are present. Not a hazard under normal conditions of use. Page 1 of 5 TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: YELLOW Revision Date: 02/09/01 POTENTIAL HEALTH EFFECTS: Short Term Exposure Inhalation: -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Testing and/or information on this or similar toners, or on the constituents of this toner indicate low inhalation toxicity. As with exposure to high concentrations of any dust, minimal respiratory tract irritation may occur if excessive amounts of toner dust are inhaled. Exposure not probable with intended use. No adverse chronic effects known at expected levels of use. Exposure not probable with intended use. Skin Contact: Eye Contact: Ingestion: Testing and/or information on this or similar toners, or on the constituents of this toner indicate this toner is not a skin irritant and is of low dermal toxicity. Toner is not a dermal sensitizer. Exposure not probable with intended use. Rare individuals may note skin rash with repeated contact. Exposure not probable with intended use. Toner may act as a mechanical irritant. Exposure not probable with intended use. No adverse chronic effects known. Exposure not probable with intended use. Testing and/or information on this or similar toners, or on the constituents of this toner indicate low oral toxicity. Exposure not probable with intended use. No adverse chronic effects known. Exposure not probable with intended use. SECTION 4 - FIRST AID MEASURES Inhalation: If symptoms, such as shortness of breath or persistent coughing are experienced, remove source of contamination and move individual to fresh air. If symptoms persist, seek medical attention. Skin Contact: Wash affected area with soap and water. Should irritation occur, seek medical attention. Eye Contact: Do not rub eyes. Flush immediately with plenty of water. Remove contact lenses and continue flushing for at least 15 minutes. Seek medical attention if irritation develops and persists. Ingestion: If conscious, immediately wash mouth out with plenty of water. Seek medical attention. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: YELLOW Revision Date: 02/09/01 SECTION 5 - FIRE FIGHTING MEASURES Flash Point: Not applicable Autoignition: Not available Lower Flammability Limit: 34.5 g/m3 Extinguishing Media: CO2 , water spray or fog, dry chemical, or foam. Firefighting: NIOSH approved self-contained breathing apparatus may be required if a large number of cartridges are involved. Fire and Explosion Hazard: Like many finely divided materials, toner dust, in high concentrations can form an explosive mixture in air which, if ignited, could result in a dust explosion. Sensitivity to Mechanical Impact: None Sensitivity to Static Discharge: High concentrations can form an explosive mixture in air which, if ignited, could result in dust explosion. Hazardous Combustion Products: Carbon dioxide, carbon monoxide, phenol derivatives and low molecular weight organics. NFPA Ratings (Scale 0 – 4) Health = 1 Fire = 1 Reactivity = 0 SECTION 6 - ACCIDENTAL RELEASE MEASURES Occupational Spill: If a dust cloud is possible due to spills involving a large number of cartridges, remove all sources of ignition such as open sparks, flames or static discharge to prevent the ignition of the dust. Minimize dust generation during clean up. Sweep up spill with non-metallic broom and dustpan. To avoid possible dust explosion, do not use vacuum cleaners to cleanup spills. Contain for disposal. Oil permeated sweeping compound may assist in the cleanup of large amounts of toner spilled on nonporous surfaces. SECTION 7 - HANDLING AND STORAGE Store away from oxidizing materials. When handling, minimize generation of dust. Supply adequate ventilation. STORE IN A COOL, DRY PLACE [below 95o F (35o C) recommended to prevent caking]. SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION Ventilation: Eye Protection: Protective Clothing: Gloves: Mechanical room ventilation is recommended. None required for intended use in printer. None required for intended use in printer. None required for intended use in printer. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: YELLOW Revision Date: 02/09/01 SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES Description: Cartridge contains toner; finely divided yellow solid with plastic-like odor. Melting Point: Not available Softening Point: 95-101o C Pressurized: No Boiling Point: Not applicable pH: Not applicable Specific Gravity (H20 = 1): 1.16 @ 20o C Evaporation Rate: Not applicable, solid Water Solubility: Insoluble % Volatility: Not applicable, solid SECTION 10 - STABILITY AND REACTIVITY Stability: Stable Conditions to Avoid: Combustible atmospheres of toner dust. Ignition sources, excessive heat, sparks and open flame. Incompatibilities: Strong oxidizers, acids, and alkalines. Hazardous Decomposition: Carbon dioxide, carbon monoxide, nitrogen oxides, phenol derivatives and unidentified organics. Hazardous Polymerization: This product will not polymerize. SECTION 11 - TOXICOLOGY INFORMATION Acute Toxicity: Not expected to be acutely toxic: LD50 (oral, rat) expected to be >2000 mg/kg, based on data from similar toners. Chronic Toxicity: Not expected to be chronically toxic. Industry tests on similar generic toner showed no signs of overt toxicity. Rats exposed to high levels of toner showed a chronic inflammatory response and a mild to moderate degree of lung fibrosis. There were no pulmonary changes of any type at the lower toner exposure level, which is most relevant in regard to potential human exposures. Toner is not listed by IARC, NTP, or OSHA. SECTION 12 - ECOLOGICAL INFORMATION Environmental Impact rating (0-4): Not available Acute Aquatic Toxicity: Not available Degradability: Not available Log Bioconcentration Factor (BCF): Not available Log Octanol/Water Partition Coefficient: Not available SECTION 13 - DISPOSAL INFORMATION If discarded, this product is not a hazardous waste either by listing or by characteristic. However, it is the responsibility of the product user to determine at the time of disposal whether a material has been contaminated and should be classified as a hazardous waste. Disposal is subject to national and provincial regulations. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: YELLOW Revision Date: 02/09/01 SECTION 14 - TRANSPORTATION INFORMATION This product is not regulated as a hazardous material by the DOT. SECTION 15 - REGULATORY INFORMATION All ingredients are registered under the Toxic Substances Control Act (TSCA) or under polymer exemption. All ingredients are exempt, registered or considered registered (polymers) under the European Inventory of Existing Commercial Chemical Substances (EINECS/ELINCS). All ingredients are exempt, registered or considered registered (polymers) under the Canadian Domestic Substances List (DSL/NDSL). None of the product ingredients are listed as Emergency Planning and Community Right-toKnow Act (EPCRA) - Section 302: Extremely Hazardous Substances (EHS). None of the product components are present above the minimum quantities of listed chemicals in EPCRA Section 313 Supplier Notification. This product contains no known materials which the State of California has found to cause cancer, birth defects or other reproductive harm -California Proposition 65. SECTION 16 - OTHER Disclaimer: Data is most current known to Toshiba at the time of preparation and is believed to be accurate. No warranty as to its accuracy or completeness is expressed or implied. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: MAGENTA Revision Date: 02/09/01 SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: Part Number: Family: Company: e-STUDIO6CP Toner Cartridge --- Magenta 15A3109 Contains toner Toshiba America Business Solutions, Inc. 2 Musick Irvine, CA 92618-163 Emergency Telephone No: 800-424-9300 SECTION 2 - GENERAL COMPOSITION OF TONER CONTAINED IN CARTRIDGE COMPONENT PERCENT(wt.) CAS# Polyester Resin Polypropylene Wax Organic Boron Compound Organic Pigment Amorphous Silica 75-90 0.5-5 0.1-3 3-10 <3 41259-36-3 9003-07-0 114803-11-1 980-26-7 68909-20-6 OSHA PEL (1) (1) 66(1) (1) 80 mg/ m3 %SiO2 ACGIH TLV (1) (1) (1) (1) 10 mg/ m3 Notes: (1) Specific workplace limits have not been established. SECTION 3 - HAZARDS IDENTIFICATION The following information is based on data obtained from testing of the product or similar products and on the characteristics of component chemicals: Primary Routes of Entry: Toner is contained in cartridge. Exposure potential includes incidental inhalation of toner dust and possible minimal skin contact during cartridge change. There is no evidence that toner is absorbed through the skin. Signs and Symptoms of Exposure: Toner on skin or mucus membranes (mouth, eyes & nose). Medical Conditions Aggravated by Exposure: None known at intended levels of use. Exposure to high airborne dust concentrations, including toner, may aggravate existing respiratory conditions. Physical Hazards : As with most finely divided dusts, explosion is possible when extremely high concentrations of dust and an ignition source are present. Not a hazard under normal conditions of use. Page 1 of 5 TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: MAGENTA Revision Date: 02/09/01 POTENTIAL HEALTH EFFECTS: Short Term Exposure Inhalation: -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Testing and/or information on this or similar toners, or on the constituents of this toner indicate low inhalation toxicity. As with exposure to high concentrations of any dust, minimal respiratory tract irritation may occur if excessive amounts of toner dust are inhaled. Exposure not probable with intended use. No adverse chronic effects known at expected levels of use. Exposure not probable with intended use. Skin Contact: Eye Contact: Ingestion: Testing and/or information on this or similar toners, or on the constituents of this toner indicate this toner is not a skin irritant and is of low dermal toxicity. Toner is not a dermal sensitizer. Exposure not probable with intended use. Rare individuals may note skin rash with repeated contact. Exposure not probable with intended use. Toner may act as a mechanical irritant. Exposure not probable with intended use. No adverse chronic effects known. Exposure not probable with intended use. Testing and/or information on this or similar toners, or on the constituents of this toner indicate low oral toxicity. Exposure not probable with intended use. No adverse chronic effects known. Exposure not probable with intended use. SECTION 4 - FIRST AID MEASURES Inhalation: If symptoms, such as shortness of breath or persistent coughing are experienced, remove source of contamination and move individual to fresh air. If symptoms persist, seek medical attention. Skin Contact: Wash affected area with soap and water. Should irritation occur, seek medical attention. Eye Contact: Do not rub eyes. Flush immediately with plenty of water. Remove contact lenses and continue flushing for at least 15 minutes. Seek medical attention if irritation develops and persists. Ingestion: If conscious, immediately wash mouth out with plenty of water. Seek medical attention. Advice to Doctor: There are no specific antidotes. Milk or water may be given to dilute the product. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: MAGENTA Revision Date: 02/09/01 SECTION 5 - FIRE FIGHTING MEASURES Flash Point: Not applicable Autoignition: Not available Flammability Limits (%): Not applicable Extinguishing Media: CO2 , water spray or fog, dry chemical, or foam. Firefighting: NIOSH approved self-contained breathing apparatus may be required if a large number of cartridges are involved. Fire and Explosion Hazard: Like many finely divided materials, toner dust, in high concentrations can form an explosive mixture in air which, if ignited, could result in a dust explosion. Sensitivity to Mechanical Impact: None Sensitivity to Static Discharge: High concentrations can form an explosive mixture in air which, if ignited, could result in dust explosion. Hazardous Combustion Products: Carbon dioxide, carbon monoxide, and low molecular weight organics. NFPA Ratings (Scale 0 – 4) Health = 1 Fire = 1 Reactivity = 0 SECTION 6 - ACCIDENTAL RELEASE MEASURES Occupational Spill: If a dust cloud is possible due to spills involving a large number of cartridges, remove all sources of ignition such as open sparks, flames or static discharge to prevent the ignition of the dust. Minimize dust generation during clean up. Sweep up spill with non-metallic broom and dustpan. To avoid possible dust explosion, do not use vacuum cleaners to cleanup spills. Contain for disposal. Oil permeated sweeping compound may assist in the cleanup of large amounts of toner spilled on nonporous surfaces. SECTION 7 - HANDLING AND STORAGE Store away from oxidizing materials. When handling, minimize generation of dust. Supply adequate ventilation. STORE IN A COOL, DRY PLACE. SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION Ventilation: Eye Protection: Protective Clothing: Gloves: Mechanical room ventilation is recommended. None required for intended use in printer. None required for intended use in printer. None required for intended use in printer. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: MAGENTA Revision Date: 02/09/01 SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES Description: Cartridge contains toner; finely divided magenta solid with plastic-like odor. Melting Point: Not available Softening Point: 95-110o C Pressurized: No Boiling Point: Not applicable pH: Not applicable Specific Gravity (H20 = 1): 1.1 Evaporation Rate: Not applicable, solid Water Solubility: Insoluble % Volatility: Not applicable, solid SECTION 10 - STABILITY AND REACTIVITY Stability: Stable Conditions to Avoid: Combustible atmospheres of toner dust. Ignition sources, excessive heat, sparks and open flame. Incompatibilities: Strong oxidizers, acids, or alkalines. Hazardous Decomposition: Carbon dioxide, carbon monoxide, nitrogen oxides, phenol derivatives and unidentified organics. Hazardous Polymerization: This product will not polymerize. SECTION 11 - TOXICOLOGY INFORMATION Acute Toxicity: Not expected to be acutely toxic: LD50 (oral, rat) and LC50 (inhalation, rat) expected to be >5000 mg/kg, based on data from similar toners. Chronic Toxicity: Not expected to be chronically toxic. Industry tests on similar generic toner showed no signs of overt toxicity. Rats exposed to high levels of toner showed a chronic inflammatory response and a mild to moderate degree of lung fibrosis. There were no pulmonary changes of any type at the lower toner exposure level, which is most relevant in regard to potential human exposures. Toner is not listed by IARC, NTP, or OSHA. SECTION 12 - ECOLOGICAL INFORMATION Environmental Impact rating (0-4): Not available Acute Aquatic Toxicity: Not available Degradability: Not available Log Bioconcentration Factor (BCF): Not available Log Octanol/Water Partition Coefficient: Not available SECTION 13 - DISPOSAL INFORMATION If discarded, this product is not a hazardous waste either by listing or by characteristic. However, it is the responsibility of the product user to determine at the time of disposal whether a material has been contaminated and should be classified as a hazardous waste. Disposal is subject to national and provincial regulations. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: MAGENTA Revision Date: 02/09/01 SECTION 14 - TRANSPORTATION INFORMATION This product is not regulated as a hazardous material by the DOT. SECTION 15 - REGULATORY INFORMATION All ingredients are registered under the Toxic Substances Control Act (TSCA) or under polymer exemption. All ingredients are exempt, registered or considered registered (polymers) under the European Inventory of Existing Commercial Chemical Substances (EINECS/ELINCS). All ingredients are exempt, registered or considered registered (polymers) under the Canadian Domestic Substances List (DSL/NDSL). None of the product ingredients are listed as Emergency Planning and Community Right-toKnow Act (EPCRA) - Section 302: Extremely Hazardous Substances (EHS). None of the product components are present above the minimum quantities of listed chemicals in EPCRA Section 313 Supplier Notification. This product contains no known materials which the State of California has found to cause cancer, birth defects or other reproductive harm -California Proposition 65. SECTION 16 - OTHER Disclaimer: Data is most current known to Toshiba at the time of preparation and is believed to be accurate. No warranty as to its accuracy or completeness is expressed or implied. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: CYAN Revision Date: 02/09/01 SECTION 1 - CHEMICAL PRODUCT AND COMPANY IDENTIFICATION Product Name: P/N: Chemical Family: Company: Toshiba e-STUDIO6CP Toner Cartridge --- Cyan 15A3107 Contains toner Toshiba America Business Solutions, Inc. 2 Musick Irvine, CA 92618-1631 Emergency Telephone No: 800-424-9300 SECTION 2 - GENERAL COMPOSITION OF TONER CONTAINED IN CARTRIDGE COMPONENT Polyester Resin Polypropylene Wax Organic Boron Compound Organic Pigment Amorphous Silica Notes: PERCENT (WT.) 75-90 4-6 3-5 3-10 <3 CAS# OSHA PEL ACGIH TLV (1) 9010-79-1 114803-11-1 147-14-8 68611-44-9 7631-86-9 (2) (2) (2) (2) 80 mg/ m3 %SiO2 (2) (2) (2) (2) 10 mg/ m3 (1) Trade secret or patented molecule (NJTSRN 80100252-5001) (2) Specific workplace limits have not been established SECTION 3 - HAZARDS IDENTIFICATION The following information is based on data obtained from testing of the product or similar products and on the characteristics of component chemicals: Primary Routes of Entry: Toner is contained in cartridge. Exposure potential includes incidental inhalation of toner dust and possible minimal skin contact during cartridge change. There is no evidence that toner is absorbed through the skin. Signs and Symptoms of Exposure: Toner on skin or mucus membranes (mouth, eyes & nose). Medical Conditions Aggravated by Exposure: None known at intended levels of use. Exposure to high airborne dust concentrations, including toner, may aggravate existing respiratory conditions. Physical Hazards : As with most finely divided dusts, explosion is possible when extremely high concentrations of dust and an ignition source are present. Not a hazard under normal conditions of use. Page 1 of 5 TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: CYAN POTENTIAL HEALTH EFFECTS: Short Term Exposure Inhalation: -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Testing and/or information on this or similar toners, or on the constituents of this toner indicate low inhalation toxicity. As with exposure to high concentrations of any dust, minimal respiratory tract irritation may occur if excessive amounts of toner dust are inhaled. Exposure not probable with intended use. No adverse chronic effects known at expected levels of use. Exposure not probable with intended use. Skin Contact: Eye Contact: Ingestion: Testing and/or information on this or similar toners, or on the constituents of this toner indicate this toner is not a skin irritant and is of low dermal toxicity. Toner is not a dermal sensitizer. Exposure not probable with intended use. Rare individuals may note skin rash with repeated contact. Exposure not probable with intended use. Toner may act as a mechanical irritant. Exposure not probable with intended use. No adverse chronic effects known. Exposure not probable with intended use. Testing and/or information on this or similar toners, or on the constituents of this toner indicate low oral toxicity. Exposure not probable with intended use. No adverse chronic effects known. Exposure not probable with intended use. SECTION 4 - FIRST AID MEASURES Inhalation: If symptoms, such as shortness of breath or persistent coughing are experienced, remove source of contamination and move individual to fresh air. If symptoms persist, seek medical attention. Skin Contact: Wash affected area with soap and water. Should irritation occur, seek medical attention. Eye Contact: Do not rub eyes. Flush immediately with plenty of water. Remove contact lenses and continue flushing for at least 15 minutes. Seek medical attention if irritation develops and persists. Ingestion: If conscious, immediately wash mouth out with plenty of water. Seek medical attention. Page 2 of 5 TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: CYAN SECTION 5 - FIRE FIGHTING MEASURES Flash Point: Not applicable Autoignition: Not available Flammability Limits (%): Not applicable Extinguishing Media: CO2 , water spray or fog, dry chemical, or foam. Firefighting: NIOSH approved self-contained breathing apparatus may be required if a large number of cartridges are involved. Fire and Explosion Hazard: Like many finely divided materials, toner dust, in high concentrations can form an explosive mixture in air which, if ignited, could result in a dust explosion. Sensitivity to Mechanical Impact: None Sensitivity to Static Discharge: High concentrations can form an explosive mixture in air which, if ignited, could result in dust explosion. Hazardous Combustion Products: Carbon dioxide, carbon monoxide, nitrogen oxides, phenol derivatives and low molecular weight organics. NFPA Ratings (Scale 0 – 4) Health = 1 Fire = 1 Reactivity = 0 SECTION 6 - ACCIDENTAL RELEASE MEASURES Occupational Spill: If a dust cloud is possible due to spills involving a large number of cartridges, remove all sources of ignition such as open sparks, flames or static discharge to prevent the ignition of the dust. Minimize dust generation during clean up. Sweep up spill with non-metallic broom and dustpan. To avoid possible dust explosion, do not use vacuum cleaners to cleanup spills. Contain for disposal. Oil permeated sweeping compound may assist in the cleanup of large amounts of toner spilled on nonporous surfaces. SECTION 7 - HANDLING AND STORAGE Store away from oxidizing materials. When handling, minimize generation of dust. Supply adequate ventilation. STORE IN A COOL, DRY PLACE [below 95o F (35o C) recommended to prevent caking]. SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION Ventilation: Eye Protection: Protective Clothing: Gloves: Mechanical room ventilation is recommended. None required for intended use in printer. None required for intended use in printer. None required for intended use in printer. T Page 1 of 35˜˜ TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: CYAN SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES Description: Cartridge contains toner; finely divided cyan solid with plastic-like odor. Melting Point: Not available Softening Point: 95-101o C Pressurized: No Boiling Point: Not applicable pH: Not applicable Specific Gravity (H20 = 1): 1.16 @ 20o C Evaporation Rate: Not applicable, solid Water Solubility: Insoluble % Volatility: Not applicable, solid SECTION 10 - STABILITY AND REACTIVITY Stability: Stable Conditions to Avoid: Combustible atmospheres of toner dust. Ignition sources, excessive heat, sparks and open flame. Incompatibilities: Strong oxidizers, acids, and alkalines. Hazardous Decomposition: Carbon dioxide, carbon monoxide, phenol derivatives and unidentified organics. Hazardous Polymerization: This product will not polymerize. SECTION 11 - TOXICOLOGY INFORMATION Acute Toxicity: Not expected to be acutely toxic: LD50 (oral, rat) expected to be >2000 mg/kg, based on data from similar toners. Chronic Toxicity: Not expected to be chronically toxic. Industry tests on similar generic toner showed no signs of overt toxicity. Rats exposed to high levels of toner showed a chronic inflammatory response and a mild to moderate degree of lung fibrosis. There were no pulmonary changes of any type at the lower toner exposure level, which is most relevant in regard to potential human exposures. Toner is not listed by IARC, NTP, or OSHA. SECTION 12 - ECOLOGICAL INFORMATION Environmental Impact rating (0-4): Not available Acute Aquatic Toxicity: Not available Degradability: Not available Log Bioconcentration Factor (BCF): Not available Log Octanol/Water Partition Coefficient: Not available SECTION 13 - DISPOSAL INFORMATION If discarded, this product is not a hazardous waste either by listing or by characteristic. However, it is the responsibility of the product user to determine at the time of disposal whether a material has been contaminated and should be classified as a hazardous waste. Disposal is subject to national and provincial regulations. page 4 of 5 TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: CYAN SECTION 14 - TRANSPORTATION INFORMATION This product is not regulated as a hazardous material by the DOT. SECTION 15 - REGULATORY INFORMATION All ingredients are registered under the Toxic Substances Control Act (TSCA) or under polymer exemption. All ingredients are exempt, registered or considered registered (polymers) under the European Inventory of Existing Commercial Chemical Substances (EINECS/ELINCS). All ingredients are exempt, registered or considered registered (polymers) under the Canadian Domestic Substances List (DSL/NDSL). None of the product ingredients are listed as Emergency Planning and Community Right-toKnow Act (EPCRA) - Section 302: Extremely Hazardous Substances (EHS). None of the product components are present above the minimum quantities of listed chemicals in EPCRA Section 313 Supplier Notification. This product contains no known materials which the State of California has found to cause cancer, birth defects or other reproductive harm -California Proposition 65. SECTION 16 - OTHER Disclaimer: Data is most current known to Toshiba at the time of preparation and is believed to be accurate. No warranty as to its accuracy or completeness is expressed or implied. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: BLACK Revision Date: 01/29/01 POTENTIAL HEALTH EFFECTS: Short Term Exposure Inhalation: -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Short Term Exposure -- Long Term Exposure -- Testing and/or information on this or similar toners, or on the constituents of this toner indicate low inhalation toxicity. As with exposure to high concentrations of any dust, minimal respiratory tract irritation may occur if excessive amounts of toner dust are inhaled. Exposure not probable with intended use. No adverse chronic effects known at expected levels of use. Exposure not probable with intended use. Skin Contact: Eye Contact: Ingestion: Testing and/or information on this or similar toners, or on the constituents of this toner indicate this toner is not a skin irritant and is of low dermal toxicity. Toner is not a dermal sensitizer. Exposure not probable with intended use. Rare individuals may note skin rash with repeated contact. Exposure not probable with intended use. Toner may act as a mechanical irritant. Exposure not probable with intended use. No adverse chronic effects known. Exposure not probable with intended use. Testing and/or information on this or similar toners, or on the constituents of this toner indicate low oral toxicity. Exposure not probable with intended use. No adverse chronic effects known. Exposure not probable with intended use. SECTION 4 - FIRST AID MEASURES Inhalation: If symptoms, such as shortness of breath or persistent coughing are experienced, remove source of contamination and move individual to fresh air. If symptoms persist, seek medical attention. Skin Contact: Wash affected area with soap and water. Should irritation occur, seek medical attention. Eye Contact: Do not rub eyes. Flush immediately with plenty of water. Remove contact lenses and continue flushing for at least 15 minutes. Seek medical attention if irritation develops and persists. Ingestion: If conscious, immediately wash mouth out with plenty of water. Seek medical attention. Advice to Doctor: There are no specific antidotes. Milk or water may be given to dilute the product. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: BLACK Revision Date: 01/29/01 SECTION 5 - FIRE FIGHTING MEASURES Flash Point: Not applicable Autoignition: Not available Flammability Limits (%): Not applicable Extinguishing Media: CO2 , water spray or fog, dry chemical, or foam. Firefighting: NIOSH approved self-contained breathing apparatus may be required if a large number of cartridges are involved. Fire and Explosion Hazard: Like many finely divided materials, toner dust, in high concentrations can form an explosive mixture in air which, if ignited, could result in a dust explosion. Sensitivity to Mechanical Impact: None Sensitivity to Static Discharge: High concentrations can form an explosive mixture in air which, if ignited, could result in dust explosion. Hazardous Combustion Products: Carbon dioxide, carbon monoxide, and low molecular weight organics. NFPA Ratings (Scale 0 – 4) Health = 1 Fire = 1 Reactivity = 0 SECTION 6 - ACCIDENTAL RELEASE MEASURES Occupational Spill: If a dust cloud is possible due to spills involving a large number of cartridges, remove all sources of ignition such as open sparks, flames or static discharge to prevent the ignition of the dust. Minimize dust generation during clean up. Sweep up spill with non-metallic broom and dustpan. To avoid possible dust explosion, do not use vacuum cleaners to cleanup spills. Contain for disposal. Oil permeated sweeping compound may assist in the cleanup of large amounts of toner spilled on nonporous surfaces. SECTION 7 - HANDLING AND STORAGE Store away from oxidizing materials. When handling, minimize generation of dust. Supply adequate ventilation. STORE IN A COOL, DRY PLACE. SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION Ventilation: Eye Protection: Protective Clothing: Gloves: Mechanical room ventilation is recommended. None required for intended use in printer. None required for intended use in printer. None required for intended use in printer. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: BLACK Revision Date: 01/29/01 SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES Description: Cartridge contains toner; finely divided black solid with plastic-like odor. Melting Point: Not available Softening Point: 95-110o C Pressurized: No Boiling Point: Not applicable pH: Not applicable Specific Gravity (H20 = 1): 1.1 Evaporation Rate: Not applicable, solid Water Solubility: Insoluble % Volatility: Not applicable, solid SECTION 10 - STABILITY AND REACTIVITY Stability: Stable Conditions to Avoid: Combustible atmospheres of toner dust. Ignition sources, excessive heat, sparks and open flame. Incompatibilities: Strong oxidizers Hazardous Decomposition: Carbon dioxide, carbon monoxide, and unidentified organics. Hazardous Polymerization: This product will not polymerize. SECTION 11 - TOXICOLOGY INFORMATION Acute Toxicity: Not expected to be acutely toxic: LD50 (oral, rat) and LC50 (inhalation, rat) expected to be >5000 mg/kg, based on data from similar toners. Chronic Toxicity: Not expected to be chronically toxic. Industry tests on similar generic toner showed no signs of overt toxicity. Rats exposed to high levels of toner showed a chronic inflammatory response and a mild to moderate degree of lung fibrosis. There were no pulmonary changes of any type at the lower toner exposure level, which is most relevant in regard to potential human exposures. Pure carbon black, a minor component of this toner, has been listed by IARC as a group 2B (possible carcinogen) based on rat “lung particulate overload” studies. Toner is not listed by IARC, NTP, or OSHA. SECTION 12 - ECOLOGICAL INFORMATION Environmental Impact rating (0-4): Not available Acute Aquatic Toxicity: Not available Degradability: Not available Log Bioconcentration Factor (BCF): Not available Log Octanol/Water Partition Coefficient: Not available SECTION 13 - DISPOSAL INFORMATION If discarded, this product is not a hazardous waste either by listing or by characteristic. However, it is the responsibility of the product user to determine at the time of disposal whether a material has been contaminated and should be classified as a hazardous waste. Disposal is subject to national and provincial regulations. TOSHIBA MATERIAL SAFETY DATA SHEET e-STUDIO6CP TONER CARTRIDGE: BLACK Revision Date: 01/29/01 SECTION 14 - TRANSPORTATION INFORMATION This product is not regulated as a hazardous material by the DOT. SECTION 15 - REGULATORY INFORMATION All ingredients are registered under the Toxic Substances Control Act (TSCA) or under polymer exemption. All ingredients are exempt, registered or considered registered (polymers) under the European Inventory of Existing Commercial Chemical Substances (EINECS/ELINCS). All ingredients are exempt, registered or considered registered (polymers) under the Canadian Domestic Substances List (DSL/NDSL). None of the product ingredients are listed as Emergency Planning and Community Right-toKnow Act (EPCRA) - Section 302: Extremely Hazardous Substances (EHS). None of the product components are present above the minimum quantities of listed chemicals in EPCRA Section 313 Supplier Notification. This product contains no known materials which the State of California has found to cause cancer, birth defects or other reproductive harm -California Proposition 65. SECTION 16 - OTHER Disclaimer: Data is most current known to Toshiba at the time of preparation and is believed to be accurate. No warranty as to its accuracy or completeness is expressed or implied.