Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Digital Temperature Transmitter Head mounting, universally programmable for resistance thermometers, thermocouples, resistance sensors and mV sensors Characteristics • Input for 2-, 3- or 4-wire resistance thermometers; thermocouples of type T, E, J, L, K, N, U, R, S, B, W3 or W5; or mV sensors up to 800 mV • Configurable for PC, MS - Windows from 3.11 operating surface "DTM - Control" • Analog output 4 ... 20 mA, reversible, 2-wire technics • Temperature linear output for input signals for resistance thermometers and thermocouples • Galvanic insulation • Optional - protection, intrinsically safe EEx ia IIC T4 / T5 / T6 or EEx ib IIC T4 / T5 / T6 Description - The configuration is done with the help of a PC and the configuration set. The desired configuration is defined in the programme surface "DTM-Control". A communication interface (programming unit) conveys the data to the digital temperature transmitter. The bidirectional communication also enables the presentation of the measurement values on the PC. . Temperature transmitters installed in ex-areas are also configurable, as the communication interface is designed as a protection barrier between the ex- and the non-ex-area. Furthermore the PC is protected from damage by a galvanic insulation. The configuration set is available as supporting appliance. . The transmitters are delivered either with a standard configuration or configured according to the specifications of the customer when this is p o s s i b l e . . . + + 3 2 4 22 mm - 1 By means of configuration 16 input signals can be chosen among. Temperatures from -200 °C to +2300 °C can be measured. . mA 6 mm 33 mm 49,5 mm 28,5 mm Digital temperature transmitters are designed for universal use in industrial installations. These measurement value transmitters are characterized by the extensive possibilities for configuration, for example for sensor type, measure span and error indication, suitable and stable accuracy, galvanic insulation and immunity to interference from electro magnetic influence (EMI-protection). The compactly designed head mounting case can be fitted in almost all DIN connecting heads. . TM-DIG1E.CDR Technical data Input Measurement range (configurable): Resistance thermometers 2-, 3- or 4-wire -200 ... + 850 °C (Measure span min. 25K) - 60 ... + 500 °C (Measure span min. 25K) Thermocouples -200 ... + 400 °C (Measure span min. 50K) -100 ... +1000 °C (Measure span min. 50K) -100 ... +1200 °C (Measure span min. 50K) -100 ... + 900 °C (Measure span min. 50K) -180 ... +1372 °C (Measure span min. 50K) -180 ... +1300 °C (Measure span min. 100K) -200 ... + 600 °C (Measure span min. 75K) - 50 ... +1760 °C (Measure span min. 200K) - 50 ... +1760 °C (Measure span min. 200K) +400 ... +1820 °C (Measure span min. 200K) Resistance sensors 0 ... 5 kOhm (Measure span 30 Ohm) mV sensors -10 ... 800 mV (Measure span 5 mV) (Pt100) (Ni100) (type T) (type E) (type J) (type L) (type K) (type N) (type U) (type R) (type S) (type B) Configuration: By means of PC and configuration set (available as supp.) Software: DTM - Control Analog output (configurable): 4 - 20 mA, 20 - 4 mA programmable, 2-wire technics Output signal: Temperature linear Output limit (configurable): 3,8 mA ... 21,5 mA (specification of use) min. 3,8 mA ... max. 20,5 mA (NAMUR) min. 3,6 mA ... max. 21,5 mA (not active) Load: RA < (UB - 9V) 0,021 A Span drift: < ± 0,05 % of measure span Temperature effect: < ± 0,01 % of measure span / K Load effect: < ± 0,01 % of measure span / 100 Ohm Power supply effect: < 0,005 % of measure span / V Attenuation (configurable): min. 0,5 s, 1 s ... 60 s Measurement value updating: approx. 2 / s Indication signal in case of sensor failure and internal transmitter failure: 3,5 mA ... 23,0 mA (configurable substitute value) > 21,0 mA (saturated signal) < 3,6 mA (cut-off signal) Power supply Supply voltage: 9 - 36 VDC (no EEx-protection); 9 - 30 VDC (with EEx-prot.) Insulation voltage: 1500 VAC, 60 s Design EEx-protection (optional): EEx ia IIC T4 / T5 / T6 or EEx ib IIC T4 / T5 / T6 Ambient conditions Operating- / storing temperature: -40 ... +85 °C optionally -50 ... +105 °C Dimensions Case: Ø 49,5 mm x 28,5 mm Fixing: 2 threads for M 4 (at 33 mm distance) Material of case: synthetic Colour: blue Weight: approx. 0,07 kg Terminals: Screw terminal on the top panel for max. 1,5 mm². Screws captive. Output Accuracy TM-DIG2E.CDR Operating, adjustment instructions Load diagram Load RA in Ohm The allowable load is dependent on the voltage of the loop supply. 1286 1000 714 0 0 9 24 30 (Ex) 36 UB in Volt Configuration of terminals Input mV sensor + = - 2 3 4 - 20 mA loop Resistance thermometer / Resistance sensor in 4-wire 3-wire 2-wire 1 1 1 2 3 4 Thermocouple 1 + - 3 4 2 2 * 2 1 - mA mA 3 3 3 4 4 + * If the cold junction compensation is done with the help of an external resistance thermometer (2-wire-switch): Terminal 1 + Terminal 4 - + 4 + * Terminal connecting plan Pay careful attention to the terminal connecting plan, especially when the digital temperature transmitter is installed in an EEx area. Ex-Barrier Input Interrupt connection + - yellow * green * Transmitter + red / rot - black / schwarz Safe area EEx area + red black + + + + 4 43 3 mA - - - - 2 2 1111 1 Supply + yellow / gelb - green / grün COM DTM - System Programmiereinheit Digitales Temperaturmess - System ! D Müller Industrie - Elektronik GmbH Am kurzen Wege 2 a 31535 Neustadt Telefon 05032/64003 Telefax 05032/64004 RS 232-C Attention : " yellow * " and " green * " should be connected only if the digital temperature transmitter is to be configured during running operation. TM-DIG3E.CDR Ordering code W D X X X X No. Configuration Configuration Configuration Output 0 0 0 0 1 Basic configuration Thermocouple type T 2 Pt100 2-wire 3 X X XXX protection Error output Measurement range none none please specify Thermocouple 20 - 4 mA type B EEx ia IIC T4 / T5 / T6 saturated signal e.g. 0...600 °C Thermocouple type E Thermocouple type W3 EEx ib IIC T4 / T5 / T6 cut-off signal Pt100 3-wire Thermocouple type J Thermocouple type W5 4 Pt100 4-wire Thermocouple type L 5 Ni100 2-wire Thermocouple type K 6 Ni100 3-wire Thermocouple type N 7 Ni100 4-wire Thermocouple type U 8 Resistance sensor Thermocouple type R 9 mV sensor Thermocouple type S TM-DIG4E.CDR 4 - 20 mA Subject to change, as of 09/99