ODSL 9
Optical laser distance sensors
en 01-2010/02 50112186
Dimensioned drawing
50 … 100mm
18 - 30 V
A
DC
z High resolution 0.01mm
z Reflection-independent distance
information
z Highly insensitive to extraneous light
z Configurable measurement mode
z Configurable measurement data preprocessing and filter
z M12 turning connector
B
C
D
E
F
G
H
J
Reference edge for the
measurement
Optical axis
Device plug M12
Receiver
Transmitter
LCD display
Indicator diode yellow
Indicator diode green
Control buttons
Electrical connection
We reserve the right to make changes • DS_ODSL9_100_en.fm
ODSL 9/66…
ODSL 9/C6…
ODSL 9/C66…
ODSL 9/D26…
ODSL 9/D36…
ODSL 9/V6…
ODSL 9/V66…
IP 67
IEC 60947...
IEC 60947...
Accessories:
(available separately)
z Mounting systems
z Configuration software
z Cable with M12 connector (K-D …)
Leuze electronic GmbH + Co. KG
[email protected] • www.leuze.com
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
ODSL 9/…-100-… - 01
ODSL 9
Specifications
Tables
Optical data
Measurement range 1)
Resolution
Light source
Wavelength
Light spot
Laser warning notice
50 … 100mm
0.01mm
laser
655nm
divergent, 1x1mm2 at 100mm
see remarks
Error limits (relative to measurement distance)
Absolute measurement accuracy 1)
Repeatability 2)
B/W detection thresh. (6 … 90% rem.)
Temperature compensation
± 0.5%
± 0.25%
≤ 0.5%
yes 3)
Timing
Measurement time
Response time 1)
Delay before start-up
2ms
≤ 6ms
≤ 300ms
Electrical data
Operating voltage UB
…C6/C66/V6/V66
…D26/D36/66
Residual ripple
Open-circuit current
Switching output
Signal voltage high/low
Analog output
…V6/V66
…C6/C66
…D26/D36
Serial interface
Transmission protocol
Indicators
Green LED
Yellow LED
18 … 30VDC (incl. residual ripple)
10 … 30VDC (incl. residual ripple)
≤ 15% of UB
≤ 180mA
push-pull switching output 4),
PNP light switching, NPN dark switching
≥ (UB -2 V)/≤ 2V
voltage 1 … 10V / 0 … 10V / 1 … 5V / 0 … 5V, RL ≥ 2kΩ
current 4 … 20mA, RL ≤ 500Ω
RS 232/RS 485, 9600 … 57600Bd,
1 start bit, 8 data bits, 1 stop bit, no parity
14 bit, 16 bit, ASCII, Remote Control
Teach-in on GND
continuous light
flashing
off
continuous light
flashing
off
Teach-in on +UB
ready
fault
teaching procedure
no voltage
object inside teach-in measurement distance
teaching procedure
object outside teach-in measurement distance
Remarks
Mechanical data
Housing
Optics cover
Weight
Connection type
plastic
glass
approx. 50g
M12 connector, 5-pin
Environmental data
Ambient temp. (operation/storage)
Protective circuit 5)
VDE safety class 6)
Protection class
Laser class
Standards applied
-20°C … +50°C / -30°C … +70°C
1, 2, 3
II, all-insulated
IP 67
2 (acc. to EN 60825-1)
IEC 60947-5-2
1) Luminosity coefficient 6% … 90%, complete measurement range, "Standard" operating mode, at 20°C,
medium range of UB, measurement object ≥ 50x50mm²
2) Same object, identical environmental conditions, measurement object ≥ 50x50mm²
3) Typ. ± 0.02 %/K
4) The push-pull switching outputs must not be connected in parallel
5) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
6) Rating voltage 50VAC
Order guide
Analog current output
1 teachable push/pull output
2 push/pull outputs
Analog voltage output
1 teachable push/pull output
2 push/pull outputs
Serial digital output
RS 232, 1 push/pull output
RS 485, 1 push/pull output
Only switching outputs
2 teachable push/pull outputs
ODSL 9/…-100-… - 01
Diagrams
Designation
Part No.
ODSL 9/C6-100-S12
ODSL 9/C66-100-S12
50111167
50111171
ODSL 9/V6-100-S12
ODSL 9/V66-100-S12
50111168
50111172
ODSL 9/D26-100-S12
ODSL 9/D36-100-S12
50111169
50111170
ODSL 9/66-100-S12
50111173
z Measurement time
depends on the reflectivity
of the measurement
object and on the measurement mode.
z Approved purpose:
The ODSL 9 laser
distance sensors are
optoelectronic sensors for
the optical, contactless
measurement of the
distance to objects.
This product may only be
used by qualified
personnel and must only
be used for the approved
purpose. This sensor is
not a safety sensor and is
not to be used for the
protection of persons.
2010/02
ODSL 9
Optical laser distance sensors
Analog output: characteristic curve for factory setting
A
B
C
D
E
F
Area not defined
Linearity not defined
Measurement range
Object present
No object detected
Measurement distance
Serial output: transmission protocol for factory setting
9600Bd, 1 start bit, 8 data bits, 1 stop bit,
transmission protocol ASCII measurement values
Transmission format: MMMMM<CR>
MMMMM = 5-digit measurement value in mm (resolution 1mm)
<CR> = ASCII character "Carriage Return" (x0D)
Leuze electronic GmbH + Co. KG
[email protected] • www.leuze.com
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
ODSL 9/…-100-… - 01
ODSL 9
ODSL 9/…-100-… - 01
2010/02
Related documents