Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
ODSL 9 Optical laser distance sensors en 01-2010/02 50112186 Dimensioned drawing 50 … 100mm 18 - 30 V A DC z High resolution 0.01mm z Reflection-independent distance information z Highly insensitive to extraneous light z Configurable measurement mode z Configurable measurement data preprocessing and filter z M12 turning connector B C D E F G H J Reference edge for the measurement Optical axis Device plug M12 Receiver Transmitter LCD display Indicator diode yellow Indicator diode green Control buttons Electrical connection We reserve the right to make changes • DS_ODSL9_100_en.fm ODSL 9/66… ODSL 9/C6… ODSL 9/C66… ODSL 9/D26… ODSL 9/D36… ODSL 9/V6… ODSL 9/V66… IP 67 IEC 60947... IEC 60947... Accessories: (available separately) z Mounting systems z Configuration software z Cable with M12 connector (K-D …) Leuze electronic GmbH + Co. KG [email protected] • www.leuze.com In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 ODSL 9/…-100-… - 01 ODSL 9 Specifications Tables Optical data Measurement range 1) Resolution Light source Wavelength Light spot Laser warning notice 50 … 100mm 0.01mm laser 655nm divergent, 1x1mm2 at 100mm see remarks Error limits (relative to measurement distance) Absolute measurement accuracy 1) Repeatability 2) B/W detection thresh. (6 … 90% rem.) Temperature compensation ± 0.5% ± 0.25% ≤ 0.5% yes 3) Timing Measurement time Response time 1) Delay before start-up 2ms ≤ 6ms ≤ 300ms Electrical data Operating voltage UB …C6/C66/V6/V66 …D26/D36/66 Residual ripple Open-circuit current Switching output Signal voltage high/low Analog output …V6/V66 …C6/C66 …D26/D36 Serial interface Transmission protocol Indicators Green LED Yellow LED 18 … 30VDC (incl. residual ripple) 10 … 30VDC (incl. residual ripple) ≤ 15% of UB ≤ 180mA push-pull switching output 4), PNP light switching, NPN dark switching ≥ (UB -2 V)/≤ 2V voltage 1 … 10V / 0 … 10V / 1 … 5V / 0 … 5V, RL ≥ 2kΩ current 4 … 20mA, RL ≤ 500Ω RS 232/RS 485, 9600 … 57600Bd, 1 start bit, 8 data bits, 1 stop bit, no parity 14 bit, 16 bit, ASCII, Remote Control Teach-in on GND continuous light flashing off continuous light flashing off Teach-in on +UB ready fault teaching procedure no voltage object inside teach-in measurement distance teaching procedure object outside teach-in measurement distance Remarks Mechanical data Housing Optics cover Weight Connection type plastic glass approx. 50g M12 connector, 5-pin Environmental data Ambient temp. (operation/storage) Protective circuit 5) VDE safety class 6) Protection class Laser class Standards applied -20°C … +50°C / -30°C … +70°C 1, 2, 3 II, all-insulated IP 67 2 (acc. to EN 60825-1) IEC 60947-5-2 1) Luminosity coefficient 6% … 90%, complete measurement range, "Standard" operating mode, at 20°C, medium range of UB, measurement object ≥ 50x50mm² 2) Same object, identical environmental conditions, measurement object ≥ 50x50mm² 3) Typ. ± 0.02 %/K 4) The push-pull switching outputs must not be connected in parallel 5) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs 6) Rating voltage 50VAC Order guide Analog current output 1 teachable push/pull output 2 push/pull outputs Analog voltage output 1 teachable push/pull output 2 push/pull outputs Serial digital output RS 232, 1 push/pull output RS 485, 1 push/pull output Only switching outputs 2 teachable push/pull outputs ODSL 9/…-100-… - 01 Diagrams Designation Part No. ODSL 9/C6-100-S12 ODSL 9/C66-100-S12 50111167 50111171 ODSL 9/V6-100-S12 ODSL 9/V66-100-S12 50111168 50111172 ODSL 9/D26-100-S12 ODSL 9/D36-100-S12 50111169 50111170 ODSL 9/66-100-S12 50111173 z Measurement time depends on the reflectivity of the measurement object and on the measurement mode. z Approved purpose: The ODSL 9 laser distance sensors are optoelectronic sensors for the optical, contactless measurement of the distance to objects. This product may only be used by qualified personnel and must only be used for the approved purpose. This sensor is not a safety sensor and is not to be used for the protection of persons. 2010/02 ODSL 9 Optical laser distance sensors Analog output: characteristic curve for factory setting A B C D E F Area not defined Linearity not defined Measurement range Object present No object detected Measurement distance Serial output: transmission protocol for factory setting 9600Bd, 1 start bit, 8 data bits, 1 stop bit, transmission protocol ASCII measurement values Transmission format: MMMMM<CR> MMMMM = 5-digit measurement value in mm (resolution 1mm) <CR> = ASCII character "Carriage Return" (x0D) Leuze electronic GmbH + Co. KG [email protected] • www.leuze.com In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0 ODSL 9/…-100-… - 01 ODSL 9 ODSL 9/…-100-… - 01 2010/02