Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Linearly Regulated Power Supply 19"/3U 23.5W Triple Output CM 2 Ordering Information Type Output ( ) Power Boost Input Voltage * Installation Width Article No. *1 CM 2 O1 = 12V ; 0.5A O2 = 5V ; 0.5A O3 = 5V ; 3A 230 Vac 14HP/3U 130-000-00 * Range alterable by soldering (caution: fuse change) Dimensions *1 without front panel in mm Connector Pin Assignment H11 - Output 3 + Output 3 + Output 2 - Output 2 + Output 1 - Output 1 Live L1 Neutral N Earth PE 1 11/2014 Free pins may not be connected external! Pin 2 5 11 14 20 23 26 29 32 leading Doc.: 96320615.01 - also effective: description no.: 95930003 --- KNIEL does not accept any liability for typographical or other errors. All specifications are subject to change without prior notice. --- Linearly Regulated Power Supply 19"/3U 23.5W Triple Output CM 2 Technical Data Guaranteed values after a warm-up period of approx. 15 min. at nominal load, measured at the unit`s output. Output Output Voltage Adjustment Range (±) Output Current Nominal Current Limiting Characteristic Curve Type of Regulation Efficiency Voltage Deviation for Load Change 0... 100% (static) Mains Voltage Change Vin min-Vin max Residual Ripple (100Hz) Dynamic Voltage Deviation for ∆Io = 10... 90% Inom Regulation Time for ∆Io = 10... 90% Inom Starting Delay Overload Protection Temperature Coefficient O1 O2 O3 12 1 5 0.5 5 0.5 0.5 0.5 0.6 0.6 fold back linearly regulated ≥ 39 3 3.6 ≤ 15 ≤ 15 ≤ 10 ≤ 10 ≤ 10 ≤5 ≤ 10 ≤ 10 ≤5 [mV] ≤ 100 ≤ 100 ≤ 100 [µs] [ms] ≤ 100 ≤ 100 ≤ 150 continuous short-circuit-proof ≤ 200 [Vdc] [V] [A] [A] [%] [mV] [mV] [mVpp] [ppm/K] ≤ 100 Input Voltage Nominal [Vac] 115 230 Operating Range (alterable by soldering) [Vac] ±10% ≈ 103-127 ±10% Frequency [Hz] 50-400 ±10% ≈ 45-440 50-400 ±10% Max. Input Current (nominal range) [A] 0.6 0.3 Starting Inrush Current ∫ i 2 dt ; I p [A2 s] ; [A] ≤ 0.03 ; ≤ 6 Worst Case ≤ 0.01 ; ≤ 3 Unit Fuse (primary, internal) [A] T 0.63 T 0.315 Operating Temperature Range (measured 1cm from the heat sink) [ºC] -25 ... +70, without derating Storage Temperature Range [ºC] -40 ... +85 Weight approx. [kg] 2 For definitions, informations about electrical safety, EMC and mechanical stressability see description. Doc.: 96320615.01 - also effective: description no.: 95930003 ≈ 207-253 ≈ 45-440 11/2014 2