Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
HEC-50LTA-XXPSAA Rev A A. Features High Efficiency (Up to 89%). Active Power Factor Correction (Typical 0.95). Isolation Class II All-Round Protection: OVP/SCP/OTP/OPP. Fully isolated plastic case with IP20 and dry location. 1-10V, PWM, and resistance dimming function. Class 2 and SELV. B. Description The HEC-50LTA-XXPSAA Series operate from a 90 ~ 305Vac input range. They are designed to be highly efficient and highly reliable. Features include over voltage protection, short circuit protection, and over temperature protection. C. Models Input Voltage Range Output Voltage Range Note 1 Note 4 1920mA 90 ~ 305Vac 1400mA Max. Output Power Efficiency Power Factor Note 2 Note 2 21V~28V 50 W 89% 0.95 HEC-50LTA-28PSAA 90 ~ 305Vac 27V~36V 50 W 89% 0.95 HEC-50LTA-36PSAA 1200mA 90 ~ 305Vac 31V~42V 50 W 89% 0.95 HEC-50LTA-42PSAA 1050mA 90 ~ 305Vac 36V~48V 50 W 89% 0.95 HEC-50LTA-48PSAA Output Current Model Number D. Electronic Specifications - Input Specifications Parameter Min. Typ. Max. Input Voltage (V) 90 - 305 Input Frequency (Hz) 47 Notes 63 - - 0.6 Measured at full load and 100Vac input. - - 0.3 Measured at full load and 277Vac input. Leakage Current (mA) - - 0.7 At 277Vac 60Hz input. Inrush Current (A) - - 40 - 0.16 A2s At 220Vac input 25°C Cold Start. Duration=100µs, 10%Ipk-10%Ipk. 0.92 - - - 20 25 Input AC Current (A) Inrush Current (I2t) Power Factor At 277Vac input, full load. THD (%) http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 1 HEC-50LTA-XXPSAA Rev A - Output Specifications Parameter Min. Typ. Max. Notes Output Current (mA) Io = 1920 mA 1824 2016 Io = 1400 mA 1330 1470 Io = 1200 mA 1140 1260 Io = 1050 mA 997 1103 No Load Output Voltage (V) Io = 1920 mA Io = 1400 mA 35 ---- ---- 50 Io = 1200 mA 63 Io = 1050 mA 63 Output Ripple Voltage (V) 10% ---- ---- Output Voltage Overshoot (%) - - 110 Line Regulation (%) - - ±3 Load Regulation (%) - - ±5 Turn-on Delay Time (s) - 0.5 1.0 Min. Typ. Max. - - - - - - Vomax There will be no damage or hazardous conditions occurred with no loading. Measured by 20 MHz bandwidth oscilloscopes and the output paralleled a 0.1uF ceramic capacitor and a 10uF electrolytic capacitor. At full load condition. Measured at 220Vac input. - General Specifications Parameter Notes Efficiency (%) Io = 1920 mA Io = 1400 mA Io = 1200 mA Io = 1050 mA 87 88 Measured at full load and 120Vac input. 88 88 Efficiency (%) Io = 1920 mA 89 Io = 1400 mA - - 89 Io = 1200 mA - - 89 Io = 1050 mA - - 89 MTBF (hours) 320,000 - - 100,000 - Life Time (hours) http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 Measured at full load and 277Vac input. Measured at full load 50°C ambient temperature (MIL-HDBK-217F). Measured at rated input voltage with full load, Case temperature=60°C @ Tc point.See life time vs. Tc curve for the details. 2 HEC-50LTA-XXPSAA Rev A Case Temperature (°C) - Dimensions Millimeters(L × W × H) - 80 186 × 62 × 37.1 Net Weight (g) - Protection Functions Parameter Min. Typ. Over Voltage Protection Max. 1.50 Vo Notes Hiccup mode. The power supply shall be self-recovery when the fault condition is removed. Protection-Tc Hiccup mode. When the case temperature is higher than 110°C, the power supply output will turn off automatically; when the case temperature is lower than 75°C, the power supply output will be auto recovery. Short Circuit Protection No damage shall occur when any output operating in a short circuit condition. The power supply shall be self-recovery when the fault condition is removed. Over Temperature - Environmental Specifications Parameter Min. Typ. Max. Notes Operating Temperature (°C) -40 - +60 Humidity: 20% RH to 80% RH; See Derating Curve for more details. Storage Temperature (°C) -40 - +80 Humidity: 10% RH to 90% RH. - Safety and EMC Compliance Safety Category Standard UL/CUL UL8750, UL1310 Class 2, CSA C22.2 NO. 223-M91 Class 2. CE EN 61347-1, EN61347-2-13. EMI Standards Note 6 Notes EN 55015 Conducted emission Test & Radiated emission Test. EN 61000-3-2 Harmonic current emissions. EN 61000-3-3 Voltage fluctuations & flicker. FCC Part 15 FCC 47 CFR Part 15 Subpart B, ICES-003 Issue 4 ANSI C63.4-2003 EMS Standards Notes EN 61000-4-2 Electrostatic Discharge (ESD): 8 KV air discharge, 4 KV contact discharge. EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test-RS. EN 61000-4-4 Electrical Fast Transient / Burst-EFT: Level 2, Criteria A. EN 61000-4-5 Surge Immunity Test: AC Power Line: line to line 1 KV. EN 61000-4-6 Conducted Radio Frequency Disturbances Test-CS. http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 3 HEC-50LTA-XXPSAA Rev A EN 61000-4-8 Power Frequency Magnetic Field Test. EN 61000-4-11 Voltage Dips. EN 61547 Electromagnetic Immunity Requirements Applies To Lighting Equipment. Notes: 1. Normal input voltage range 100~277Vac. 2. Measured at input 220V with a full load. 3. All specifications are typical at 25 °C unless otherwise stated. 4. Constant current operation region is preferably 80%~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static curve for more details. 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again E. Dimming Control The dimmer control is operated from an input signal (DC voltage / PWM signal / Variable Resistor). Please refer to the diagram. Notes: 1. If the dimming pin is not used, Dimming pin can be open. Parameter Min. Typ. Max. 1-10V Dimming Voltage (V) 1 - + 10.8 PWM Signal 5 10 + 10.8 -0 - +10K Ω 0~10K Variable Resistor ( Ω) http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 Notes 4 HEC-50LTA-XXPSAA Rev A - Dimming Model Output Voltage Range Parameter Min. Typ. Max. Notes Io = 1920 mA 22 - 28 Measured at 100-277Vac input. Io = 1400 mA 30 - 36 Measured at 100-277Vac input. Io = 1200 mA 36 - 42 Measured at 100-277Vac input. Io = 1050 mA 36 - 42 Measured at 100-277Vac input. - DC Voltage Dimming Curve - PWM Signal Dimming Curve http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 5 HEC-50LTA-XXPSAA Rev A - Variable Resistor Curve F. Electronic Curve - Derating Curve http://www.hec-group.com.tw/ [email protected] - Static Curve TEL:+886-6-356-0606 FAX:+886-6-356-0505 6 HEC-50LTA-XXPSAA Rev A - Power Factor Characteristics Curve - Efficiency Characteristics Curve - Life Time vs. Case Temperature Curve http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 7 HEC-50LTA-XXPSAA Rev A G. Mechanical Outline H. RoHS Compliance Outline Our products comply with the European Directive 2011/65/EU, calling for the elimination of lead and other hazardous substances from electronic products. I. Revision History Change Date Description of Change Rev. Item 2013-11-01 A Datasheets Release http://www.hec-group.com.tw/ [email protected] TEL:+886-6-356-0606 FAX:+886-6-356-0505 From To / / 8