Download CM4-M35/50/70 CM4

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
CM4-M35/50/70
CM4-H50/70
Catalog Number:____________________________
4" Open HID Downlight
Project:_____________________________________
Type:_______________________________________
Description
Four inch vertical lamp HID downlight. Rated for use with 35, 50, or 70 watt metal halide lamps and 50 or 70 watt
high pressure sodium. Wide variety of trim options.
Features
• Adjustable socket cup.
• Pre-Installed quick connectors.
• Easy, snap fit installation.
• cUL listed for damp locations and through branch circuit
Wiring.
• Variety of wet location trim options.
• Detachable ballast tray for easy maintenance.
SAMPLE CATALOG NUMBER: CM4-M50-V45
CATALOG SYSTEM AND OPTIONS
Plaster Frame
CM4
-
Electrical System
Fuse Option
_________
Metal Halide
M35
_________
1
CDM35/PAR30
CDM35/PAR20 (open rated)
M502
Trims
-
_______
V45 - Clear Reflector
V43 - Gold Reflector
V44 - Black Reflector
V46 - White Reflector
V47 - Wheat Reflector
V45BC - Black Baffle Clear Lens Insert4
V45BP - Black Baffle, C73 Prismatic Lens4
V45B - Clear Reflector, Black Baffle
V45WB - Clear Reflector, White Baffle
V45WBC - White Baffle Clear Lens Insert4
V45WBP - White Baffle, C73 Prismatic Lens4
V45C - Clear Cone , Clear Lens Insert4
V45P - Clear Cone, C73 Prismatic Lens4
V46C - White Splay, Clear Lens Insert4
V46P - White Splay, C73 Prismatic Lens4
FS2
FS4
FS6
3
MP50/C/U/MED (open rated)
M702
3
MP70/C/U/MED (open rated)
High Pressure Sodium
H50
LU50/D/MED
H70
LU70/D/MED
ers for greater stability. Two L-brackets hold the ballast
tray in place along the edge of the plaster tray.
2. Socket - Medium base screw porcelain socket rated
for 650W, 250V maximum.
3. Socket Cup - The socket cup attaches to the trim without tools and incorporates a socket scale to provide for
uniform socket positioning.
4. Junction Box - Plaster frame integrated 47 cu.in. junction box with four 1/2" and two 1" knockouts. Electrical
connections are made through a single junction box
door, which allows all electrical systems to snap into
place on the frame. All electrical systems come standard
with pre-installed quick connectors for fast and easy
electrical connections.
5. cUL Listed - cUL approved for damp location and
through branch circuit wiring with up to 8 #12 AWG
conductors. Lens trims are cUL Listed for wet location.
FRAME
1. Metal Plaster Frame - 20 gauge die stamped metal
frame with flanged edges to provide a smooth handling
surface. The frame can be easily converted in the field to
6'' and 8'' aperture sizes with optional interchangeable
aperture rings. Frames can be installed before lamp
source or wattage has been determined.
Note: Suitable for installation in environmental air-handling ceilings.
2. Mounting - Adjustable spring steel butterfly brackets
accommodate CH24 or CH48 channel bar hangers, BH3
flat bar hangers, or 1/2" EMT conduit. Frame can be
supported with aircraft cable where required. Ballast
trays attach via two butterfly nuts. Frame can be supported with aircraft cable where required.
ELECTRICAL SYSTEM
1. Ballast - Systems come equipped with standard
120/277V, 60 Hertz, -20° F minimum starting temperature (120/347V ballast available as an option), dual
15"
tap, high power factor magnetic ballasts. Ballasts attach
(381 mm)
to an adjustable ballast tray that straddles the bar
hang-
Footnotes:
1. HID fuse kits vary depending on wattage/wattage.
2. Use open rated fixture lamps only.
3. Protected lamp required.
4. UL Listed Wet Location.
General Notes:
See Fuse Kit Chart below to determine the correct fuse kit
for your application.
grooves to reduce aperture glare. Non-reflective matte
black or white painted finishes.
3. Lenses - Tempered clear or C73 Prismatic glass lenses.
Lenses are easily removable from below the ceiling for
relamping.
4. Installation - Capri One trims attach directly to the
frame via expandable torsion springs.
5. Lens Trims - cUL Listed wet location rated.
ACCESSORIES
(Order separately)
27" Flat Bar Hangers .............................................BH3
26" C-Channel Bar Hangers ................................CH24
50" C-Channel Bar Hangers ................................CH48
TRIMS
1. Reflector - Precision spun .050 aluminum. Removable
polycarbonate trim ring is standard.
2. Baffle - Precision spun .040 aluminum with deep
DIMENSIONS
20 1/32"
(487 mm)
9 1/2"
(241 mm)
15"
(381 mm)
4 7/8"
(124 mm)
5 3/32"
(129 mm)
6 5/32"
(156 mm)
20 1/32"
(487 mm)
1
/2"
(13 mm)
Electrical Operating Characteristics
Input Amps
Starting
Operating
Input
Lamp
Wattage Watts
120v 277v 120v
277v
M35
49
0.6
0.3
0.6
0.3
M50
72
0.8
0.4
0.7
0.3
M70
94
1.0
0.5
0.9
0.4
H50
65
0.7
0.4
0.7
0.3
H70
90
1.0
0.5
0.9
0.4
Fuse
120v 277v
FS4
FS2
FS4
FS2
FS6
FS2
FS4
FS2
FS6
FS2
REV. 03/07
CM4-M39-V45
THOMAS LIGHTING CANADA:
CAPRI LIGHTING
189 Bullock Drive, Markham, Ontario, Canada L3P 1W4
776 South Green St., Tupelo, MS 38804
PROTECTED
LAMP
Phone 905.294.9570 FAX 800.268.0003
Phone 662.842.7212 FAX 662.841.5501
9 1/2"
(241 mm)
4 7/8"
(124 mm)
www.caprilighting.com
1
/2"
(13 mm)
www.thomaslightingcanada.com
CO3-1
4" HID TRIMS
V45
Clear Reflector
V47
Wheat Reflector
Gold Reflector
V43
V45B
V45WB
Clear Reflector,
Black Baffle
Clear Reflector,
White Baffle
Black Baffle, Glass Lens Insert
V42BC Clear Lens*
V42BP C73 Prismatic Lens* (shown)
White Baffle, Glass Lens Insert
V45WBC Clear Lens*
*UL Listed for wet location.
V45WBP C73 Prismatic Lens*(shown)
White Splay, Glass Lens Insert
V46C Clear Lens*
V46P C73 Prismatic Lens*(shown)
Clear Cone, Glass Lens Insert
V45C Clear Lens*
V45P C73 Prismatic Lens* (shown)
White Reflector
V46
Black Reflector
V44
PHOTOMETRICS
CM4-M35-V42
4" H.I.D. 35W Metal Halide Downlight
Clear Reflector
Lamp: (1) CDM35/PAR30
IES Spacing Criteria: .5
Candlepower Summary
Candlepower Curve
75°
65°
55°
45°
35°
25°
15°
5°
Zone Degree
0° Candelas
90 .............................0
85 .............................0
80 .............................0
75 .............................0
70 .............................0
65 .............................2
60 .............................8
55 ............................16
50 ............................43
45 ............................77
40 ...........................157
35 ...........................340
30 ...........................644
25 ..........................1069
20 ..........................1770
15 ..........................3174
10 ..........................4875
5 ...........................6186
0 ...........................6650
Beam Angle: 29°
Efficiency: 98.9%
Coefficients of Utilization
Conversion Factors
Ceiling Cavity Reflectance
80
Room
50
Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
117
111
105
98
93
90
85
81
79
76
72
50
Wall Reflectance
30
10
50
30
10
50
CU for Floor Cavity Reflectance = 20%
117
117
110 110
110
101
109
107
105 103
102
97
101
97
100
96
94
93
94
92
94
92
90
91
90
85
91
88
84
86
84
81
86
82
80
83
81
77
83
80
77
81
77
73
80
76
72
78
73
70
77
72
69
75
70
68
73
69
67
72
68
65
71
68
65
69
10
30
10
101
96
93
89
84
81
78
75
71
68
67
101
95
91
86
82
79
76
71
69
67
64
For average footcandle calculations.
Multiply footcandles by conversion factor.
Trim
Catalog #
V43
V44
V46
V47
Conversion
Factor
.93
.87
.69
.89
These coefficients were computed by the zonal-cavity method, I.E.S. recommended practice, and prepared from the candlepower distribution data in
photometric test no. 21268
90:
0:
F21268
CM4-M50-V42
Lamp: (1) MP50/C/U/MED
IES Spacing Criteria: 0.9
Efficiency: 40%
Description: 4" H.I.D. 50W Metal Halide Downlight
Clear Reflector
Candlepower Summary
Candlepower Curve
75°
65°
55°
45°
35°
25°
15°
5°
Zone Degree
0° Candelas
90 .............................0
85 .............................0
80 .............................0
75 .............................0
70 .............................1
65 .............................2
60 .............................7
55 ............................26
50 ...........................136
45 ...........................355
40 ...........................554
35 ...........................688
30 ...........................763
25 ...........................846
20 ...........................954
15 ..........................1093
10 ..........................1214
5 ...........................1281
0 ...........................1282
Coefficients of Utilization
80
Room
50
Cavity Ratio
0
1
2
3
4
5
6
7
8
9
10
CO3-1
48
44
40
37
34
32
29
27
25
24
22
50
Wall Reflectance
30
10
CU for Floor
48
48
43
42
39
37
35
33
32
30
27
29
27
25
24
23
23
21
19
21
19
18
50
Cavity
44
41
38
36
33
31
28
26
25
23
22
30
10
50
Reflectance = 20%
44
44
41
41
40
39
37
36
36
34
32
34
31
29
31
27
29
28
26
24
27
24
22
25
22
21
24
21
19
22
19
18
21
10
30
10
41
38
35
32
30
28
25
24
22
20
19
41
38
34
31
29
26
24
22
20
19
18
For average footcandle calculations.
Multiply footcandles by conversion factor.
Trim
Catalog #
V43
V44
V46
V47
Conversion
Factor
.93
.87
.69
.89
These coefficients were computed by the zonal-cavity method, I.E.S. recommended practice, and prepared from the candlepower distribution data in
photometric test no. 21279P
90:
0:
F21279
Conversion Factors
Ceiling Cavity Reflectance
Capri Lighting reserves the right to make changes without notice.©2005
CAPRI LIGHTING:
776 South Green St., Tupelo, MS 38804
Phone 662.842.7212 FAX 662.841.5501
THOMAS LIGHTING CANADA:
189 Bullock Drive, Markham, Ontario, Canada L3P 1W4
Phone 905.294.9570 FAX 800.268.0003
www.thomaslightingcanada.com
Related documents