Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
CM4-M35/50/70 CM4-H50/70 Catalog Number:____________________________ 4" Open HID Downlight Project:_____________________________________ Type:_______________________________________ Description Four inch vertical lamp HID downlight. Rated for use with 35, 50, or 70 watt metal halide lamps and 50 or 70 watt high pressure sodium. Wide variety of trim options. Features • Adjustable socket cup. • Pre-Installed quick connectors. • Easy, snap fit installation. • cUL listed for damp locations and through branch circuit Wiring. • Variety of wet location trim options. • Detachable ballast tray for easy maintenance. SAMPLE CATALOG NUMBER: CM4-M50-V45 CATALOG SYSTEM AND OPTIONS Plaster Frame CM4 - Electrical System Fuse Option _________ Metal Halide M35 _________ 1 CDM35/PAR30 CDM35/PAR20 (open rated) M502 Trims - _______ V45 - Clear Reflector V43 - Gold Reflector V44 - Black Reflector V46 - White Reflector V47 - Wheat Reflector V45BC - Black Baffle Clear Lens Insert4 V45BP - Black Baffle, C73 Prismatic Lens4 V45B - Clear Reflector, Black Baffle V45WB - Clear Reflector, White Baffle V45WBC - White Baffle Clear Lens Insert4 V45WBP - White Baffle, C73 Prismatic Lens4 V45C - Clear Cone , Clear Lens Insert4 V45P - Clear Cone, C73 Prismatic Lens4 V46C - White Splay, Clear Lens Insert4 V46P - White Splay, C73 Prismatic Lens4 FS2 FS4 FS6 3 MP50/C/U/MED (open rated) M702 3 MP70/C/U/MED (open rated) High Pressure Sodium H50 LU50/D/MED H70 LU70/D/MED ers for greater stability. Two L-brackets hold the ballast tray in place along the edge of the plaster tray. 2. Socket - Medium base screw porcelain socket rated for 650W, 250V maximum. 3. Socket Cup - The socket cup attaches to the trim without tools and incorporates a socket scale to provide for uniform socket positioning. 4. Junction Box - Plaster frame integrated 47 cu.in. junction box with four 1/2" and two 1" knockouts. Electrical connections are made through a single junction box door, which allows all electrical systems to snap into place on the frame. All electrical systems come standard with pre-installed quick connectors for fast and easy electrical connections. 5. cUL Listed - cUL approved for damp location and through branch circuit wiring with up to 8 #12 AWG conductors. Lens trims are cUL Listed for wet location. FRAME 1. Metal Plaster Frame - 20 gauge die stamped metal frame with flanged edges to provide a smooth handling surface. The frame can be easily converted in the field to 6'' and 8'' aperture sizes with optional interchangeable aperture rings. Frames can be installed before lamp source or wattage has been determined. Note: Suitable for installation in environmental air-handling ceilings. 2. Mounting - Adjustable spring steel butterfly brackets accommodate CH24 or CH48 channel bar hangers, BH3 flat bar hangers, or 1/2" EMT conduit. Frame can be supported with aircraft cable where required. Ballast trays attach via two butterfly nuts. Frame can be supported with aircraft cable where required. ELECTRICAL SYSTEM 1. Ballast - Systems come equipped with standard 120/277V, 60 Hertz, -20° F minimum starting temperature (120/347V ballast available as an option), dual 15" tap, high power factor magnetic ballasts. Ballasts attach (381 mm) to an adjustable ballast tray that straddles the bar hang- Footnotes: 1. HID fuse kits vary depending on wattage/wattage. 2. Use open rated fixture lamps only. 3. Protected lamp required. 4. UL Listed Wet Location. General Notes: See Fuse Kit Chart below to determine the correct fuse kit for your application. grooves to reduce aperture glare. Non-reflective matte black or white painted finishes. 3. Lenses - Tempered clear or C73 Prismatic glass lenses. Lenses are easily removable from below the ceiling for relamping. 4. Installation - Capri One trims attach directly to the frame via expandable torsion springs. 5. Lens Trims - cUL Listed wet location rated. ACCESSORIES (Order separately) 27" Flat Bar Hangers .............................................BH3 26" C-Channel Bar Hangers ................................CH24 50" C-Channel Bar Hangers ................................CH48 TRIMS 1. Reflector - Precision spun .050 aluminum. Removable polycarbonate trim ring is standard. 2. Baffle - Precision spun .040 aluminum with deep DIMENSIONS 20 1/32" (487 mm) 9 1/2" (241 mm) 15" (381 mm) 4 7/8" (124 mm) 5 3/32" (129 mm) 6 5/32" (156 mm) 20 1/32" (487 mm) 1 /2" (13 mm) Electrical Operating Characteristics Input Amps Starting Operating Input Lamp Wattage Watts 120v 277v 120v 277v M35 49 0.6 0.3 0.6 0.3 M50 72 0.8 0.4 0.7 0.3 M70 94 1.0 0.5 0.9 0.4 H50 65 0.7 0.4 0.7 0.3 H70 90 1.0 0.5 0.9 0.4 Fuse 120v 277v FS4 FS2 FS4 FS2 FS6 FS2 FS4 FS2 FS6 FS2 REV. 03/07 CM4-M39-V45 THOMAS LIGHTING CANADA: CAPRI LIGHTING 189 Bullock Drive, Markham, Ontario, Canada L3P 1W4 776 South Green St., Tupelo, MS 38804 PROTECTED LAMP Phone 905.294.9570 FAX 800.268.0003 Phone 662.842.7212 FAX 662.841.5501 9 1/2" (241 mm) 4 7/8" (124 mm) www.caprilighting.com 1 /2" (13 mm) www.thomaslightingcanada.com CO3-1 4" HID TRIMS V45 Clear Reflector V47 Wheat Reflector Gold Reflector V43 V45B V45WB Clear Reflector, Black Baffle Clear Reflector, White Baffle Black Baffle, Glass Lens Insert V42BC Clear Lens* V42BP C73 Prismatic Lens* (shown) White Baffle, Glass Lens Insert V45WBC Clear Lens* *UL Listed for wet location. V45WBP C73 Prismatic Lens*(shown) White Splay, Glass Lens Insert V46C Clear Lens* V46P C73 Prismatic Lens*(shown) Clear Cone, Glass Lens Insert V45C Clear Lens* V45P C73 Prismatic Lens* (shown) White Reflector V46 Black Reflector V44 PHOTOMETRICS CM4-M35-V42 4" H.I.D. 35W Metal Halide Downlight Clear Reflector Lamp: (1) CDM35/PAR30 IES Spacing Criteria: .5 Candlepower Summary Candlepower Curve 75° 65° 55° 45° 35° 25° 15° 5° Zone Degree 0° Candelas 90 .............................0 85 .............................0 80 .............................0 75 .............................0 70 .............................0 65 .............................2 60 .............................8 55 ............................16 50 ............................43 45 ............................77 40 ...........................157 35 ...........................340 30 ...........................644 25 ..........................1069 20 ..........................1770 15 ..........................3174 10 ..........................4875 5 ...........................6186 0 ...........................6650 Beam Angle: 29° Efficiency: 98.9% Coefficients of Utilization Conversion Factors Ceiling Cavity Reflectance 80 Room 50 Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 117 111 105 98 93 90 85 81 79 76 72 50 Wall Reflectance 30 10 50 30 10 50 CU for Floor Cavity Reflectance = 20% 117 117 110 110 110 101 109 107 105 103 102 97 101 97 100 96 94 93 94 92 94 92 90 91 90 85 91 88 84 86 84 81 86 82 80 83 81 77 83 80 77 81 77 73 80 76 72 78 73 70 77 72 69 75 70 68 73 69 67 72 68 65 71 68 65 69 10 30 10 101 96 93 89 84 81 78 75 71 68 67 101 95 91 86 82 79 76 71 69 67 64 For average footcandle calculations. Multiply footcandles by conversion factor. Trim Catalog # V43 V44 V46 V47 Conversion Factor .93 .87 .69 .89 These coefficients were computed by the zonal-cavity method, I.E.S. recommended practice, and prepared from the candlepower distribution data in photometric test no. 21268 90: 0: F21268 CM4-M50-V42 Lamp: (1) MP50/C/U/MED IES Spacing Criteria: 0.9 Efficiency: 40% Description: 4" H.I.D. 50W Metal Halide Downlight Clear Reflector Candlepower Summary Candlepower Curve 75° 65° 55° 45° 35° 25° 15° 5° Zone Degree 0° Candelas 90 .............................0 85 .............................0 80 .............................0 75 .............................0 70 .............................1 65 .............................2 60 .............................7 55 ............................26 50 ...........................136 45 ...........................355 40 ...........................554 35 ...........................688 30 ...........................763 25 ...........................846 20 ...........................954 15 ..........................1093 10 ..........................1214 5 ...........................1281 0 ...........................1282 Coefficients of Utilization 80 Room 50 Cavity Ratio 0 1 2 3 4 5 6 7 8 9 10 CO3-1 48 44 40 37 34 32 29 27 25 24 22 50 Wall Reflectance 30 10 CU for Floor 48 48 43 42 39 37 35 33 32 30 27 29 27 25 24 23 23 21 19 21 19 18 50 Cavity 44 41 38 36 33 31 28 26 25 23 22 30 10 50 Reflectance = 20% 44 44 41 41 40 39 37 36 36 34 32 34 31 29 31 27 29 28 26 24 27 24 22 25 22 21 24 21 19 22 19 18 21 10 30 10 41 38 35 32 30 28 25 24 22 20 19 41 38 34 31 29 26 24 22 20 19 18 For average footcandle calculations. Multiply footcandles by conversion factor. Trim Catalog # V43 V44 V46 V47 Conversion Factor .93 .87 .69 .89 These coefficients were computed by the zonal-cavity method, I.E.S. recommended practice, and prepared from the candlepower distribution data in photometric test no. 21279P 90: 0: F21279 Conversion Factors Ceiling Cavity Reflectance Capri Lighting reserves the right to make changes without notice.©2005 CAPRI LIGHTING: 776 South Green St., Tupelo, MS 38804 Phone 662.842.7212 FAX 662.841.5501 THOMAS LIGHTING CANADA: 189 Bullock Drive, Markham, Ontario, Canada L3P 1W4 Phone 905.294.9570 FAX 800.268.0003 www.thomaslightingcanada.com