UTILITY MATRIX Parameter Maximum height of indoor equipment (Skid) Maximum height of outdoor equipment Units m (ft) Measurement 2.7 (8’-10”) m (ft) n/a 2 2 5.9 (63) 2 2 n/a 2 2 Approximate footprint of indoor equipment (Skid) m (ft ) Approximate footprint of outdoor equipment m (ft ) Overall system footprint Empty (Shipping) Weight – Skid Max. (Operating Weight - Skid m (ft ) kg (lbs) kg (lbs) Table Connection Point size / type / location Details 1,150 (2,530) 2,600 (5,720) Tank sizes 3 Equalization/Lift Tank m (gallons) 9.0 (2,400) 3 Recirculation Tank m (gallons) 1.0 (264) 3 Permeate Tank m (gallons) 0.3 (80) Utility Requirements Power kw-hrs/yr 119,000 3 Natural Gas Nm /hr n/a 3 Cooling Water m /hr n/a 3 Chilled Water m /hr n/a 3 Hot Water m /hr n/a 3 Plant Air Nm /hr 16.0 ¼” Swagelok, SS 3 Nitrogen Nm /hr n/a 3 Soft Water or Industrial Water m /hr n/a Chemical kg/hr n/a Other kg/hr Waste Product Liquid Waste DN15 Union, PP 3 Volume m /day 2.2 TSS Concentration % Ave – 1% : Max – 5% CHRIST WATER USA, INC. 4018 112 TH AVENUE. SUITE D2 VANCOUVER, WA 98682 PHONE (360) 253-3440 FAX (360) 253-3445