www.hvac.vn
Ultrasonic Level Transmitters
The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees
as a resource only. www.hvac.vn
They may not be reproduced, published, or transmitted electronically for commercial purposes.
Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used
Overview
ULL
ULT
www.hvac.vn
UTC/UTS
ULTM
ULL Introduction
Designed for non-contact measurement of
liquid levels
Sophisticated algorithms are used to overcome
acoustic interferences and false echoes
www.hvac.vn
ULL - Specifications
Wetted Materials: Sensor: Polypropylene; Acoustic
window: ECTFE
Ranges:
ULL-1XXX: 0.25 to 5 m (0.82 to 16.4 ft )
ULL-2XXX: 0.6 to 15 m (1.96 to 49.2 ft)
Accuracy: 0.25% of max. range (at 20°C)
Enclosure: Plastic enclosure: ABS & UV resistant
body
Enclosure Rating: NEMA 4 (IP65)
www.hvac.vn
ULL- Features
Ultrasonic technology paired with automatic
temperature compensation to provide reliable and
accurate measurements in virtually all conditions
Sophisticated algorithms are used to overcome
acoustic interferences and false echoes
LCD screen and four push buttons allow for
quick and easy programming on a simple menu
structure
Diagnostic capabilities and a fail-safe output signal
www.hvac.vn
ULT - Introduction
Provides reliable, accurate, noncontact measurement of liquid
levels
Needs only a 7.6 cm diameter
column for effective measuring
surface
Purchase by range
www.hvac.vn
ULT - Specifications
Wetted Materials: Sensor: PVDF; Process connection:
303 SS; O-ring: fluoroelastomer
Ranges: 7.5 m (24.6´) , 10 m (32.8´)
Accuracy: ±0.2% of max range
Output Signal: 4 to 20 mA or 20 to 4 mA (Two-wire)
Enclosure Rating: Weather-proof meets NEMA 4X
(IP66), explosion-proof rated Class I, Div. 1, Groups B,
C, D; Class II/III, Div. 1, Groups E, F, G
Agency Approvals: CE, FM
www.hvac.vn
ULT Features
Weatherproof & Explosion Proof
Weather-proof meets IP 67
FM Approved Explosion-proof Housing
Rated Class I, Div. 1, Groups B, C, D; Class II/III, Div. 1,
Groups E, F, G.
6 digit local LCD display w/ Push Buttons
No handheld or laptop required for programming
Units selection
Tank dimensions
Easy Programming
www.hvac.vn
ULTM - Introduction
Ultrasonic level transmitter
Has embedded cellular communications and can
send SMS alerts
www.hvac.vn
ULTM - Specifications
Wetted Materials: PVDF
Range:
Liquids: 8 m (26.25´) ;
Solids: 6 m (19.69´) .
Accuracy: ±0.5 cm (±0.2˝) or 0.2% of max. range
Repeatability: 0.2% of measured range
Enclosure Material: Plastic PC/ABS+UV.
Enclosure Rating: IP65/IP67, IP68 (96 hours at
1.8 m (5.91’) water depth).
www.hvac.vn
ULTM - Features
Embedded and external temperature sensor for
any condition
Cellular Transmission data
USB for quick set up and local monitoring
Hourly alerts
Low Power consumption (battery powered)
www.hvac.vn
UTC/UTS – Introduction
Reliable, accurate, non-contact measurement of
liquid level and open channel flow even under
extremely harsh conditions
No moving parts to wear or jam
Modbus
Designed to be used with UTS sensors
www.hvac.vn
UTC - Specifications
Ranges: 0.6 to 25 m (2 to 82 ft)
Accuracy: 0.25% of max. range
Switch Type: 5 SPDT relays
Enclosure Material: ECTFE
Enclosure Rating: NEMA 4X (IP65)
Units: m, in, ft, m3/hr, GPM interchangeable
www.hvac.vn
UTS - Specifications
Wetted Materials: Polypropylene
Transducer Frequency: 25 kHz
Range: 0.6 to 25 m (2 to 82 ft)
Enclosure Rating: NEMA 4 (IP65)
www.hvac.vn
UTC/UTS – Features
Withstands extreme conditions
6-digit LCD display
Simple programming menu
5 SPDT relays
Easy to Install
Modbus RTU communication protocol
RS-232
4 to 20 mA communications
www.hvac.vn
ULL - Applications
Continuous Level Monitoring for:
Fuel Tank Level
Digester Tank Level
Chemical Tank Level
Cooling Tower Level
www.hvac.vn
ULT - Application
Continuous Level Monitoring for:
Fuel Tank Level
Digester Tank Level
Pump Lift Stations
Wet Well Level
Chemical Tank Level
Cooling Tower Level
www.hvac.vn
Beam path
ULTM - Applications
Fuel Tank Monitoring
Fuel Theft Prevention
Leakage Detection
Identification of overflow
Wastewater Monitoring
River flood Alerts
Remote Level
www.hvac.vn
UTC/UTS - Applications
Used as a flow monitor for open channels and
Level Monitoring
Designed to be mounted above open channels such
as:
Flumes
Weirs
www.hvac.vn