Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Features P16 Alarm system concept Hybrid modular system On-board wired zones 7/14 (doubling) 2-wire smoke detector input 1 On-board wireless zones 16 Maximum zones in system 16 On-board PGM 3 Maximum PGM in system 16 User + installer codes 31+1 Duress code Defaulting user code Yes Key switch zone Yes Partitions 4 "Shared" partition (common area) Yes System timers 16 Maximum keypads/modules in system 15 Event log buffer 512 PSTN communicator Plug-on In-built interface for backup communicator TTL Serial Data bus protocol KRBUS Total phone numbers: CMS reporting + personal dialing 9 Maximum phone numbers for personal dialing Up to 5 Maximum phone numbers for CMS reporting Up to 4 Reporting protocol Contact ID Voice guide for system control over PSTN Yes Voice guide for system programming over PSTN Yes P32 Features P16 "Roller" detector type Yes "Vibration" detector type Yes "Vibration" zone speed (sensitivity) 0.01 - 0.25 sec. Normal zone speed (sensitivity) 0.1 - 2.5 sec. Zone loop (detector) type Arming mode Zone definition Zone attributes PGM definition PGM attributes Rated voltage of power supply (AC) ~20 V Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) ~16 V Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) ~22 V Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge): ≤1.5 A Maximum current of slow blowing fuse used in primary AC 250 mA Maximum AC power consumption 150 mA Minimum voltage on +AUX, +BELL, +PGM outputs 12 V Maximum voltage on +AUX, +BELL, +PGM outputs 13.9 V Maximum current out of +AUX +1 A Maximum current out of +BELL +2 A Maximum current into -PGM -0.3 A Maximum current out of +PGM +0.5 A P32 Features P16 Short circuit, overload protection of +BELL, +PGM, +AUX Electronic Battery charge, +BELL, +AUX current measurement Yes Failed (waste) backup battery disconnection Yes Maximum battery charging current 0.35 A / 0.7 A Maximum current of fast blowing fuse used in battery circuit 3.15 A Control panel disconnect battery when it’s voltage less than 9.5 V Recommended backup battery 12 V, 7 Ah / 20 Hr Operational compliance +EN50131, Grade2 Overall dimensions W x H in mm 145 x 77 Environmental compliance ROHS Operating temperature Production status Latest firmware version In-field firmware upgrade (by USB) In production v0.03 Yes P32