Features
P16
Alarm system concept
Hybrid modular system
On-board wired zones
7/14 (doubling)
2-wire smoke detector input
1
On-board wireless zones
16
Maximum zones in system
16
On-board PGM
3
Maximum PGM in system
16
User + installer codes
31+1
Duress code
Defaulting user code
Yes
Key switch zone
Yes
Partitions
4
"Shared" partition (common area)
Yes
System timers
16
Maximum keypads/modules in system
15
Event log buffer
512
PSTN communicator
Plug-on
In-built interface for backup communicator
TTL Serial
Data bus protocol
KRBUS
Total phone numbers: CMS reporting + personal dialing
9
Maximum phone numbers for personal dialing
Up to 5
Maximum phone numbers for CMS reporting
Up to 4
Reporting protocol
Contact ID
Voice guide for system control over PSTN
Yes
Voice guide for system programming over PSTN
Yes
P32
Features
P16
"Roller" detector type
Yes
"Vibration" detector type
Yes
"Vibration" zone speed (sensitivity)
0.01 - 0.25 sec.
Normal zone speed (sensitivity)
0.1 - 2.5 sec.
Zone loop (detector) type
Arming mode
Zone definition
Zone attributes
PGM definition
PGM attributes
Rated voltage of power supply (AC)
~20 V
Minimum AC voltage
(note: ~16 V input voltage lets control panel to
generate max 0.7 A output current)
~16 V
Maximum AC voltage
(Note: higher than ~22 V voltage can damage control
panel)
~22 V
Maximum long term output current of control panel
(I+AUX + I+BELL + I+PGM + battery charge):
≤1.5 A
Maximum current of slow blowing fuse used in primary
AC
250 mA
Maximum AC power consumption
150 mA
Minimum voltage on +AUX, +BELL, +PGM outputs
12 V
Maximum voltage on +AUX, +BELL, +PGM outputs
13.9 V
Maximum current out of +AUX
+1 A
Maximum current out of +BELL
+2 A
Maximum current into -PGM
-0.3 A
Maximum current out of +PGM
+0.5 A
P32
Features
P16
Short circuit, overload protection of +BELL, +PGM,
+AUX
Electronic
Battery charge, +BELL, +AUX current measurement
Yes
Failed (waste) backup battery disconnection
Yes
Maximum battery charging current
0.35 A / 0.7 A
Maximum current of fast blowing fuse used in battery
circuit
3.15 A
Control panel disconnect battery when it’s voltage less
than
9.5 V
Recommended backup battery
12 V, 7 Ah / 20 Hr
Operational compliance
+EN50131, Grade2
Overall dimensions W x H in mm
145 x 77
Environmental compliance
ROHS
Operating temperature
Production status
Latest firmware version
In-field firmware upgrade (by USB)
In production
v0.03
Yes
P32