Selection Guide I/O Wiring Conversion Systems PLC-5 1771 to ControlLogix 1756 I/O Wiring Conversion Systems What’s Inside Topic Page Product Selection 3 Approximate Dimensions 11 Wiring Diagrams - Digital Inputs 19 Wiring Diagrams - Digital Outputs 47 Wiring Diagrams - Analog Inputs and Outputs 77 Wiring Diagrams - High Resolution Isolated Analog 103 Summary of Changes This publication contains new and updated information as indicated in the following table. Topic Page Analog Inputs and Outputs Product Selection - added new options for 1771-IL, 1771-OFE1 and 1771-OFE2 conversions 7 1771-N High Resolution Isolated Analog I/O Modules - New conversion options in standard and combination 8 2 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Product Selection 1771 I/O to 1756 I/O Conversion Modules I/O Conversion Modules provide a fast and efficient method for converting 1771 PLC-5 I/O to 1756 ControlLogix I/O. The I/O conversion is accomplished without removing any field wires from the existing swing arm, virtually removing the risk of wiring errors. The existing swing arms fit directly onto the edge connector of the conversion modules. The cables are pre-wired and have a connector for the conversion module on one end and a removable terminal block (RTB) on the other end. The I/O signals are routed through the conversion module and the cable to the appropriate terminals on the I/O module. The I/O Conversion System includes: • Conversion Modules (Ex: Cat No: 1492-CM1771-LD001) • Cables (Ex: Cat No: 1492-CONACAB005X) • Conversion Mounting Assembly (Ex: Cat No: 1492-MUA4-A13-A17) Conversion Modules, Cables, and Mounting Assemblies Pre-wired Cables, 25-pin Conversion Modules Pre-wired Cables, 37-pin Cover Plate Base Plate The Conversion Modules are housed in a Conversion Mounting Assembly Base Plate. This base plate has the same footprint and mounting holes as the 1771 chassis. There is no need to drill and tap new mounting holes in the control cabinet. The Conversion Mounting Assembly Cover Plate covers and helps protect the Conversion Modules while providing a place to mount the new 1756 chassis. The Cover Plate has pre-drilled and tapped mounting holes allowing the new 1756 chassis to be mounted in several locations – centered, right-justified or left-justified. There is no need to drill and tap new mounting holes in the control cabinet. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 3 Product Selection Conversion Mounting Assembly Selection Conversion Modules must be installed in a 1492 Conversion Mounting Assembly (see table below, a complete System Installation Manual is included with each assembly. Use the following steps to select the proper conversion mounting assembly: 1. Determine the quantity of each type of 1771 I/O modules used in the I/O chassis to be converted. 2. From the table below: a. Select the applicable 1492 conversion modules b. Review the Max Slots for I/O and Chassis Width data from the table below c. Select a 1756 I/O chassis which has enough I/O slots. Two I/O slots are required in the 1756 chassis for conversions where one 1771 I/O module converts to two 1756 I/O modules. d. Select the conversion mounting assembly which has enough conversion module slots. (2) conversion module slots are required in the conversion mounting assembly for conversions where (2) 1771 I/O modules convert to (1) 1756 I/O modules. The combined depth of the conversion mounting assembly with the 1756 chassis mounted on top is 10.25 inches (controller w/key) or 10.0 inches (controller w/o key). Dimension drawings are included in the System Installation Manual that ships with the Assembly. Chassis Dimensions and Max Slot Information 1771 Chassis 1756 Chassis Conversion Mounting Assembly Chassis Width(2) in (mm) Max Slots for I/O Without Power Supply With Power Supply 1771-A1B 4 9.01 (229) 12.61 (320) 1771-A2B 8 14.01 (356) 17.61 (447) 1771-A3B1(1) 12 19.01 (483) 1771-A4B 16 24.01 (610) Cat. No. Cat. No. Max Slots for I/O Chassis Width in (mm) 1756-A4 3 10.35 (263) 1756-A7 6 14.49 (368) 1756-A7 6 14.49 (368) 1756-A10 9 19.02 (483) 1756-A10 9 19.02 (483) 1756-A13 12 23.15 (588) 1756-A13 12 23.15 (588) 1756-A17 16 29.06 (738) Max Slots for Conversion Modules Chassis Width in (mm) 1492-MUA1B-A4-A7 4 9.01 (229) 1492-MUA2B-A7-A10 8 14.01 (356) 1492-MUA3B-A10-A13 12 19.01 (483) 1492-MUA4-A13-A17 16 24.01 (610) Cat. No. (1) 1771-A3B is not listed as it is used for 19 inch wide instrumentation panels. (2) Notice that the 1756 Chassis Width sometimes exceeds the 1771 Chassis Width, with or without the Power Supply. The Cover-Plate of the 1492 Conversion Mounting Assembly allows the 1756 Chassis to be Left justified, Right justified or Centered. A complete System Installation Manual ships with the 1492 Conversion Mounting Assembly. 4 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Product Selection Digital Inputs 1. Column 1: find the Catalog Number of the 1771 Module you are converting from. 2. Column 2: find the Catalog Number of the compatible 1756 Module you are converting to. In some cases more than one module exists. Review the matrix carefully and review the I/O module Installation Manuals to determine full compatibility. 3. Column 3: find the Conversion Module catalog number and order quantity. 4. Column 4: find the Conversion Cable catalog number and order quantity. 1 2 Converting From 1771 Module(1) 1771-IA 1771-IA2 1771-IAD 1771-IAD 1771-IAN 1771-IB 1771-IBD 1771-IBN 1771-IC 1771-ICD 1771-ID 1771-ID01 1771-ID16 1771-ID16 1771-IG 1771-IGD 1771-IH 1771-IM 1771-IMD 1771-IN 1771-IND 1771-IND1 1771-IQ 1771-IQ 1771-IQ16 1771-IT 1771-IV 1771-IVN Qty. 2 2 1 1 1 2 1 1 2 1 2 2 1 1 2 1 2 2 1 2 1 1 2 2 1 2 2 1 Converting to 1756 Module 1756-IA16 1756-IA16 1756-IA16 1756-IH16I 1756-IA32 1756-IB16 1756-IB16 1756-IB32 1756-IC16 1756-IC16 1756-IA16I 1756-IM16I 1756-IA16I 1756-IH16I 1756-IG16 1756-IG16 1756-IC16 1756-IM16I 1756-IM16I 1756-IN16 1756-IN16 1756-IN16 1756-IB16I 1756-IB16I 1756-IB16I 1756-IB16 1756-IV16 1756-IV32 Qty. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 4 5 Conversion Module Conversion Cable(3) Wiring Diagram Cat. No. 1492-CM1771-LD007 1492-CM1771-LD007 1492-CM1771-LD001 1492-CM1771-LD002 1492-CM1771-LD003 1492-CM1771-LD007 1492-CM1771-LD001 1492-CM1771-LD003 1492-CM1771-LD007 1492-CM1771-LD001 1492-CM1771-LD012 1492-CM1771-LD012 1492-CM1771-LD004 1492-CM1771-LD004 1492-CM1771-LA003(2) 1492-CM1771-LD006 1492-CM1771-LD007 1492-CM1771-LD007 1492-CM1771-LD002 1492-CM1771-LD007 1492-CM1771-LD001 1492-CM1771-LD001 1492-CM1771-LD007 1492-CM1771-LD014 1492-CM1771-LD004 1492-CM1771-LD007 1492-CM1771-LD014 1492-CM1771-LD005 Order 2 2 1 1 1 2 1 1 2 1 2 2 1 1 2 1 2 2 1 2 1 1 2 2 1 2 2 1 Cat. No. 1492-C005005XE 1492-C005005XE 1492-CONCAB005X 1492-CONCAB005Y 1492-CONCAB005Z 1492-C005005XE 1492-CONCAB005X 1492-CONCAB005Z 1492-C005005XE 1492-CONCAB005X 1492-C005005XL 1492-C005005XL 1492-CONCAB005Y 1492-CONCAB005Y 1492-C005005XS 1492-CONCAB005X 1492-C005005XE 1492-C005005XH 1492-CONCAB005Y 1492-C005005XE 1492-CONCAB005X 1492-CONCAB005X 1492-C005005XK 1492-C005005XJ 1492-CONCAB005Y 1492-C005005XE 1492-C005005XG 1492-CONCAB005Z Order 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Page 19 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 (1) To understand any issues concerning I/O module compatibility refer to the conversion module wiring diagrams and the Installation Manuals for the specific I/O modules involved (with particular attention to the specification and wiring instructions). (2) These 1771 Digital I/O Modules use a Swing Arm that only mounts to these Analog I/O Conversion Modules, which will therefore be used to provide for these 1771 Digital I/O conversions. (3) The 005 in the Cat. No. indicates cable length of the 1492 cable. The recommended length of 0.5 M is listed, additional lengths are listed below. 1.0M Cable = 1492-CONCAB010_, 1.0M/1.0M Cable= 1492-C010010X_,0.5M/1.0M Cable = 1492-C005010X_,1.0M/0.5M Cable = 1492-C010005X_ Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 5 Product Selection Digital Outputs 1. Column 1: find the catalog number of the 1771Module you are converting from. 2. Column 2: find the catalog number of the compatible 1756 Module you are converting to. In some cases more than one module exists. Review the matrix carefully and review the I/O module Installation Manuals to determine full compatibility. 3. Column 3: find the catalog number of the Conversion Module. 4. Column 4: find the catalog number of the Conversion Cable. 1 2 Converting from 1771 Module(1) Cat. No. Qty. 3 Converting to 1756 Module Cat. No. Qty.(2) 4 Conversion Module Cat. No. (3) 5 (4) Conversion Cable Order Qty. Cat. No. Order Qty. Wiring Diagram Page 1771-OA 1771-OAD 1771-OAN 1771-OB 1771-OBD 1771-OBD 1771-OBDS 1771-OBN 1771-OC 1771-OD 1771-OD16 1771-ODD 1771-ODZ 1771-OG 1771-OGD 1771-OM 1771-OMD 1771-ON 1771-OND 1771-OQ 1771-OQ16 1771-OR 1771-OVN 1771-OW 1771-OW16 1771-OWNA 1771-OY 1771-OYL 1 1 1 2 1 1 1 1 1 2 1 1 2 2 1 2 1 1 1 2 1 2 1 1 1 1 1 1 1756-OA8E 1756-OA16 1756-OA16 1756-OB16D 1756-OB16E 1756-OC8 1756-OB16E 1756-OB32 1756-OC8 1756-OA16I 1756-OA16I 1756-OA16I 1756-OA16I 1756-OG16 1756-OG16 1756-OA16 1756-OA16 1756-ON8 1756-ON8 1756-OB16I 1756-OB16I 1756-OA16I 1756-OV16E 1756-OX8I 1756-OW16I 1756-OW16I 1756-OX8I 1756-OX8I 1 1 2 1 1 2 1 1 1 1 1 1 1 2 2 1 1 1 2 1 1 1 2 1 1 2 1 1 1492-CM1771-LD014 1492-CM1771-LD006 1492-CM1771-LD013 1492-CM1771-LD014 1492-CM1771-LD006 1492-CM1771-LD008F 1492-CM1771-LD006 1492-CM1771-LD009F 1492-CM1771-LD014 1492-CM1771-LD012 1492-CM1771-LD010F 1492-CM1771-LD010F 1492-CM1771-LD012 1492-CM1771-LA003 1492-CM1771-LD006 1492-CM1771-LD014 1492-CM1771-LD006 1492-CM1771-LD014 1492-CM1771-LD006 1492-CM1771-LA004 1492-CM1771-LD010F 1492-CM1771-LD012 1492-CM1771-LD013 1492-CM1771-LD012 1492-CM1771-LD011 1492-CM1771-LD013 1492-CM1771-LD012 1492-CM1771-LD012 1 1 1 2 1 1 1 1 1 2 1 1 2 2 1 2 1 1 1 2 1 2 1 1 1 1 1 1 1492-CONCAB005U 1492-CONCAB005X 1492-CONCAB005S3 1492-C005005XF 1492-CONCAB005X 1492-CONCAB005S1 1492-CONCAB005X 1492-CONCAB005Z 1492-CONCAB005V 1492-C005005XM 1492-CONCAB005Y 1492-CONCAB005Y 1492-C005005XP 1492-C005005XS 1492-CONCAB005X 1492-C005005XG 1492-CONCAB005X 1492-CONCAB005W 1492-CONCAB005S2 1492-C005005XT 1492-CONCAB005Y 1492-C005005XR 1492-CONCAB005S3 1492-CONCAB005Y 1492-CONCAB005Y 1492-CONCAB005S4 1492-CONCAB005Y 1492-CONCAB005Y 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 1771-OZ 1 1756-OX8I 1 1492-CM1771-LD012 1 1492-CONCAB005Y 1 75 1771-OZL 1 1756-OX8I 1 1492-CM1771-LD012 1 1492-CONCAB005Y 1 76 (1) To understand any issues concerning I/O module compatibility refer to the conversion module wiring diagrams and the Installation Manuals for the specific I/O modules involved (with particular attention to the specification and wiring instructions). (2) Where two is indicated, these modules need to be located directly next to each other in the 1756 chassis. (3) An “F” at the end of the 1756 catalog number indicates that it is fused to match the functionality of the 1771 module being replaced. (4) The 005 in the Cat. No. indicates cable length of the 1492 cable. The recommended length of 0.5 M is listed, additional lengths are listed below. 1.0M Cable = 1492-CONCAB010_, 1.0M/1.0M Cable= 1492-C010010X_0.5M/1.0M Cable = 1492-C005010X_, 1.0M/0.5M Cable = 1492-C010005X_ 6 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Product Selection Analog Inputs and Outputs 1. Column 1: find the catalog number of the 1771Module you are converting from. 2. Column 2: find the catalog number of the compatible 1756 Module you are converting to. In some cases more than one module exists. Review the matrix carefully and review the I/O module Installation Manuals to determine full compatibility. 3. Column 3: find the catalog number of the Conversion Module. 4. Column 4: find the catalog number of the Conversion Cable. 1 2 3 4 5 Converting from 1771 Module Converting to 1756 Module Conversion Module Conversion Cable Wiring Diagram Cat. No. 1771-IFE 1771-IFF Qty. 1 1 Cat. No. 1756-IF16 1756-IF16 1771-IR 1771-IXE 1771-IXHR 1771-OFE1 1771-OFE2 Qty. Cat. No. Order Qty. Cat. No. Order Qty. Page Differential Current 1 1492-CM1771-LA002 1 1492-CONACAB005D 1 77 Differential Voltage 1 1492-CM1771-LA002 1 1492-CONACAB005C 1 78 Single End Current 1 1492-CM1771-LA001 1 1492-CONACAB005B 1 79 Single End Voltage 1 1492-CM1771-LA001 1 1492-CONACAB005A 1 80 Differential Current 1 1492-CM1771-LA002 1 1492-CONACAB005D 1 81 Differential Voltage 1 1492-CM1771-LA002 1 1492-CONACAB005C 1 82 Single End Current 1 1492-CM1771-LA001 1 1492-CONACAB005B 1 83 Single End Voltage 1 1492-CM1771-LA001 1 1492-CONACAB005A 1 84 Current 1 1492-CM1771-LA004 1 1492-CONACAB005K8 1 85 Voltage 1 1492-CM1771-LA004 1 1492-CONACAB005L8 1 86 1756-IF6I (6-ch) Current 1 1492-CM1771-LA004 1 1492-CONACAB005K 1 87 Voltage 1 1492-CM1771-LA004 1 1492-CONACAB005L 1 88 1756-IF6I (2x 4-ch) Current 2 1492-CM1771-LA004 1 1492-CONACAB005T1 1 89 Voltage 2 1492-CM1771-LA004 1 1492-CONACAB005T2 1 90 1756-IRT8I RTD 1 1492-CM1771-LA004 1 1492-CONACAB005F8 1 91 1756-IR6I RTD 1 1492-CM1771-LA004 1 1492-CONACAB005F 1 92 1756-IT6I2 Thermocouple 1 1492-CM1771-LA005 1 1492-CONACAB005G 1 93 1756-IRT8I Thermocouple 1 1492-CM1771-LA005 1 1492-CONACAB005G8 1 94 1756-IT6I2 Thermocouple 1 1492-CM1771-LA005 1 1492-CONACAB005G 1 95 1756-IRT8I Thermocouple 1 1492-CM1771-LA005 1 1492-CONACAB005G8 1 96 1 1756-OF6VI Voltage 1 1492-CM1771-LA003 1 1492-CONACAB005E 1 97 1 1756-OF8I Voltage 1 1492-CM1771-LA003 1 1492-CONACABOO5E8V 1 98 2 1756-OF8I Voltage 1 1492-CM1771-LA003 2 1492-C005005E8V 1 99 1 1756-OF6CI Current 1 1492-CM1771-LA003 1 1492-CONACAB005E 1 100 1 1756-OF8I Current 1 1492-CM1771-LA003 1 1492-CONACABOO5E8C 1 101 2 1756-OF8I Current 1 1492-CM1771-LA003 2 1492-C005005E8C 1 102 1756-IF8I 1771-IL Description 1 1 1 1 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 7 Product Selection 1771-N High Resolution Isolated Analog I/O Modules The 1771-N High Resolution Analog I/O modules are designed for use with 1771-RTPs (Remote Termination Panels) and connected by a 6 or 15 foot cable (Cat. No. 1771-NC6 or 1771-NC15). The conversion of the 1771-N Series I/O to a 1756 ControlLogix I/O can be accomplished without the removal of any field wires from the existing 1771-RTPs. Simply replace the (2) existing 1771 cables with (2) of the following cables in the table below. Each of these cables has a connector on one end that attaches directly to the existing 1771-RTP and a 1756 RTB (Removable Terminal Block) on the other end for connection to the ControlLogix I/O module. Use the following steps to select the proper conversion cables: 1. Column 2: find the catalog number of the 1771 Digital I/O module. 2. In column 3, find the catalog number of the compatible 1756 Digital I/O module. In some cases more than one module is required. Review the matrix and the I/O module installation manuals to determine full compatibility 3. In column 4, find the catalog numbers and descriptions of the appropriate cables. 1 I/O Description 2 3 Convert From: Convert To: 1771 Module 1771-NOC 1771-NIS 1771-NIV Standard 1771-N High Resolution I/O 1771-NR 1771-NT1 1771-NOV 1771-NIV1 1771-NT2 8 Qty. 1756 Module 4 5 Conversion Cable Catalog Number Qty. Cable Description Cable "A" Cable "B" Wiring Diagram Page 1 1756-OF8I 1 Current (8 Ch) 1492-CONACAB020N88 103 1 1756-OF8 1 Current (8 CH) 1492-CONACAB020N8 104 1 1756-OF6CI 2 Current (4/4 CH) 1 1756-IF8I 1 Current (8 CH) 1 1756-IF6CIS 2 Current (4/4 CH) 1 1756-IF8I 1 Current (8 CH) 1 1756-IF6I 2 Current (4/4 CH) 1 1756-IF8I 1 Voltage (8 CH) 1 1756-IF6I 2 Voltage (4/4 CH) 1492-CONACAB020N7 1492-CONACAB020N7 111 1 1756-IF6I 2 Current (A - 4 CH) / Voltage (B - 4 CH) 1492-CONACAB020N3 1492-CONACAB020N7 112 1 1756-IF6I 2 Voltage (A - 4 CH) / Current (B - 4 CH) 1492-CONACAB020N7 1492-CONACAB020N3 113 1 1756-IRT8I 1 RTD (8 CH) 1 1756-IR6I 2 RTD (4/4 CH) 1 1756-IRT8I 1 Thermocouple (8 CH) 1 1756-IT6I 2 Thermocouple (4/4 CH) 1 1756-OF8I 1 Voltage (8 CH) 1 1756-OF6VI 2 Voltage (4/4 CH) 1 1756-IF8I 1 Voltage (8 CH) 1 1756-IF6I 2 Voltage (4/4 CH) 1 1756-IRT8I 1 Thermocouple (8 CH) 1 1756-IT6I2 2 Thermocouple (4/4 CH) 1492-CONACAB020N1 1492-CONACAB020N1 1492-CONACAB020N38 1492-CONACAB020N2 1492-CONACAB020N2 1492-CONACAB020N38 1492-CONACAB020N3 1492-CONACAB020N3 1492-CONACAB020N78 1492-CONACAB020N48 1492-CONACAB020N4 1492-CONACAB020N4 1492-CONACAB020N68 1492-CONACAB020N5 1492-CONACAB020N5 1492-CONACAB020N18 1492-CONACAB020N5 1492-CONACAB020N1 1492-CONACAB020N78 1492-CONACAB020N7 1492-CONACAB020N7 1492-CONACAB020N68 1492-CONACAB020N6 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 1492-CONACAB020N6 105 106 107 108 109 110 114 115 116 117 118 119 120 121 122 123 Product Selection 1 I/O Description 2 3 Convert From: Convert To: 1771 Module 1756 Module Qty. 1771-NIVR 1771-NIVT 5 Conversion Cable Catalog Number Qty. Cable Description Cable "A" Cable "B" 1756-IRT8I RTD (4 CH) - 1492-CONACAB020N44 1756-IF8I Voltage (4 CH) 1492-CONACAB020N74 - 1756-IR6I RTD (4 CH) - 1492-CONACAB020N4 1756-IF6I Voltage (4 CH) 1492-CONACAB020N7 - 1756-IRT8I RTD (4 CH) - 1492-CONACAB020N44 1756-IF8I Current (4 CH) 1492-CONACAB020N34 - 1756-IR6I RTD (4 CH) - 1492-CONACAB020N4 Current (4 CH) 1492-CONACAB020N3 - 1756-IF6I 1 Combination 1771-N High Resolution I/O 4 1 1756-IRT8I Thermocouple (4 CH) - 1492-CONACAB020N54 1756-IF8I Voltage (4 CH) 1492-CONACAB020N74 - 1756-IT6I Thermocouple (4 CH) - 1492-CONACAB020N5 1756-IF6I Voltage (4 CH) 1492-CONACAB020N7 - 1756-IRT8I Thermocouple (4 CH) - 1492-CONACAB020N54 1756-IF8I Current (4 CH) 1492-CONACAB020N34 - 1756-IT6I Thermocouple (4 CH) - 1492-CONACAB020N5 1756-IF6I Current (4 CH) 1492-CONACAB020N3 - Wiring Diagram Page 124 125 126 127 128 129 130 131 Specifications Attribute Value Dimensions (H x D x W) 300 x 111.25 x 38.1 mm (11.81 x 4.38 x 1.5 in.) Approximate Shipping Weight 260g (0.57 lb) Storage Temperature Storage Temperature -40...+85 °C (-40...+185 °F) Operating Temperature Operating Temperature 0...+60 °C (+32...+140 °F) Operating Humidity Operating Humidity 5...95% at +55 °C (+131 °F) Shock Nonoperating Operating 50 g 30 g Operational Vibration 2 g at 10...500 Hz Agency Certifications UL Classified (UL File No. E113724) CE Certifications Compliant for all applicable directives Pollution Degree 2 Environmental Rating IP20 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 9 Product Selection Notes: 10 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Approximate Dimensions Dimensions are in. (mm). Cat No. MUA1B-A4-A7 used with Cat No. 1756-A4 10.4 [263.6 ] 9.0 [229.6 ] 9.9 [251.9 ] 2.4 [60.2 ] 5.4 [137 ] 12.5 [317.2 ] 11.1 [281.7 ] 6.1 [154 ] Left Justified 10.4 [264.1 ] 9.1 [230.7 ] 2.4 [60.1 ] 5.4 [137 ] 11.1 [281.7 ] 12.5 [317.2 ] Right Justified Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 11 Approximate Dimensions Cat No. MUA1B-A4-A7 used with Cat No. 1756-A7 14.6 [370.6 ] 9.9 [251.9 ] 9.0 [229.6 ] 2.4 [60.2 ] 6.1 [154 ] 2.4 [60.2 ] 5.4 [136.5 ] 12.5 [317.2 ] 11.1 [281.7 ] Left Justified 14.6 [370.1 ] 4.1 [104.5 ] 9.0 [229.6 ] 2.4 [60.2 ] 5.4 [137.3 ] 12.5 [317.2 ] Centered 14.6 [370.1 ] 2.4 [60.2 ] 5.4 [137.3 ] 9.1 [231.9 ] 12.5 [317.2 ] 11.1 [281.7 ] Right Justified 12 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Approximate Dimensions Cat No. MUA2B-A7-A10 used with Cat No. 1756-A7 14.6 [370.1 ] .2 [5.7 ] 14.0 [356.6 ] .3 [7.8 ] 2.4 [59.7 ] 12.5 [317.3 ] 5.4 [136 ] 11.1 [281.7 ] Centered 9.9 [251.9 ] 6.1 [154 ] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 13 Approximate Dimensions Cat No. MUA3-A10-A13 used with Cat No. 1756-A10 19.2 [486.9 ] 19.0 [483.6 ] 2.4 [60.2 ] 5.4 [137 ] 12.5 [317.3 ] 11.1 [281.7 ] Centered 9.9 [252.3 ] 6.1 [154.4 ] 14 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Approximate Dimensions Cat No. MUA3-A10-A13 used with Cat No. 1756-A13 .7 [18 ] 19.0 [483.6 ] 9.6 [243.9 ] 2.4 [60.2 ] 5.4 [137 ] 11.1 [281.7 ] 12.5 [317.3 ] 5.7 [146 ] Left Justified 23.2 [588 ] 2.4 [59.9 ] 2.2 [56.8 ] 1.9 [47.4 ] 5.4 [137 ] Centered 2.4 [60.2 ] 11.2 [285.6 ] 19.0 [483.6 ] 23.2 [588 ] 23.2 [588 ] 4.1 [103.1 ] 5.4 [137 ] 11.1 [281.7 ] Right Justified Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 15 Approximate Dimensions Cat No. MUA4-A13-A17 used with Cat No. 1756-A13 24.0 [610.6 ] 23.2 [588 ] 2.4 [60.2 ] 5.4 [137 ] 11.1 [281.7 ] Centered 9.6 [243.7 ] 5.7 [145.9 ] 16 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 12.5 [316.7 ] Approximate Dimensions Cat No. MUA4-A13-A17 used with Cat No. 1756-A17 29.1 [737.9 ] 24.0 [610.6 ] .2 [6.2 ] 4.8 [121 ] 2.4 [60.1 ] 12.5 [316.7 ] 9.9 [251.9 ] 6.1 [154 ] 11.1 [281.7 ] Left Justified 29.1 [737.9 ] 3.6 [91.7 ] 2.4 [60.1 ] 24.0 [610.6 ] 1.4 [35.6 ] 11.1 [281.7 ] 5.4 [137 ] 12.5 [316.7 ] Centered 29.1 [737.9 ] 5.1 [130 ] .4 60.1 ] 5.4 [137 ] 24.0 [610.6 ] 11.1 [281.7 ] 12.5 [316.7 ] Right Justified Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 17 Approximate Dimensions Notes: 18 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IA, IA2 to 1756-IA16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD007 L1 L2 Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 L2 A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IA , -IA2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XE Black CABLE “A” White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “B” 1756-IA16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 L2-0 L2-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 L2-1 L2-1 Conversion Module 1492-CM1771-LD007 L1 L2 Not used Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 L2 1771-WA Swing Arm From 1771-IA , -IA2 A 0 1 2 3 4 5 6 7 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IA16 RTB. Recommended cable lengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths. The input delay times for the 1771-IA, -IA2 module versus the 1756-IA16 module are as follows: 1771-IA, -IA2 1756-IA16 w/ 1492-C005005XE a) Off-to-On Delay 24ms (+/-10ms) 10ms max (plus selectable filter) b) On-to-Off Delay 24ms (+/-10ms) 8ms max (plus selectable filter) The 1771-IA, -IA2 module is rated 87V to 138V AC and 97V to 138V DC. The 1756-IA16 module is rated 79V to 132V AC only. Refer to your 1771-IA, -IA2 and 1756-IA16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-952 (Version 02)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 19 Wiring Diagrams - Digital Inputs 1771-IAD to 1756-IA16 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD001 Terminal A Terminal B Terminal C Terminal D Input 00 Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Input 17 Terminal E L1 L2 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green 1756-IA16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 L2-0 L2-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 L2-1 L2-1 1771-WH Swing Arm From 1771-IAD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The input delay times for the 1771-IAD module versus the 1756-IA16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IAD 5ms (+/-3ms) @120VAC 25ms (+/-5ms) 1756-IA16 w/ 1492-CONCAB005X 10ms max (plus selectable filter) 8ms max (plus selectable filter) The 1771-IAD module is rated 79V to 138V AC or DC. The 1756-IA16 module is rated 74V to 132V AC. If the input source voltage is DC use a 1756-IH16l and 1492-CM1771-LD002 conversion module. Refer to your 1771-IAD and 1756-IA16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-925 (Version 02)] 20 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IAD to 1756-IH16I WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD002 Terminal A Terminal B Terminal C Terminal D Input 00 A B C D 00 Input 01 01 Input 02 02 Input 03 03 Input 04 04 Input 05 05 Input 06 06 Input 07 07 Input 10 10 Input 11 11 Input 12 12 Input 13 13 Input 14 14 Input 15 15 Input 16 16 Input 17 17 + - Terminal E 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-IH16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 GND-0 IN-0 GND-1 IN-1 GND-2 IN-2 GND-3 IN-3 GND-4 IN-4 GND-5 IN-5 GND-6 IN-6 GND-7 IN-7 GND-8 IN-8 GND-9 IN-9 GND-10 IN-10 GND-11 IN-11 GND-12 IN-12 GND-13 IN-13 GND-14 IN-14 GND-15 IN-15 E 1771-WH Swing Arm From 1771-IAD Conversion Module Installation and Application Considerations The input delay times for the 1771-IAD module versus 1756-IH16I module are as follows: 1771-IAD 1756-IH16I a) Off-to-On Delay 3ms @120V DC 2ms (plus selectable filter) b) On-to-Off Delay 25ms (+/-5ms) 6ms (plus selectable filter) The 1771-IAD module is rated 79V to 138V AC or DC. The 1756-IH16I module is rated 90V to 146V DC. If the input spurce voltage is AC use a 1756-IA16 and 1492-CM1771-LD002 conversion module. Refer to your 1771-IAD and 1756-IH16I Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-927 (Version 02)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 21 Wiring Diagrams - Digital Inputs 1771-IAN to 1756-IA32 WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD003 L1 L2 Common 0 Common 2 10 30 Input 00 Input 00 Input 01 Input 01 Input 02 Input 02 Input 03 Input 03 Input 04 Input 04 Input 05 Input 05 Input 06 Input 06 Input 07 Input 07 Input 10 Input 10 Input 11 Input 11 Input 12 Input 12 Input 13 Input 13 Input 14 Input 14 Input 15 Input 15 Input 16 Input 16 Input 17 Input 17 Common 0 Common 1 Common 1 Common 2 Common 3 Common 3 1 21 2 22 3 23 4 24 5 25 6 26 7 27 8 28 11 31 12 32 13 33 14 34 15 35 16 36 17 37 18 38 9 19 20 29 39 40 Cable 1492-CONCAB005Z 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue 1756-IA32 18 36 1 19 2 20 3 21 4 22 5 23 6 24 7 25 8 26 9 27 10 28 11 29 12 30 13 31 14 32 15 33 16 34 17 35 L2-0 L2-1 IN-0 IN-16 IN-1 IN-17 IN-2 IN-18 IN-3 IN-19 IN-4 IN-20 IN-5 IN-21 IN-6 IN-22 IN-7 IN-23 IN-8 IN-24 IN-9 IN-25 IN-10 IN-26 IN-11 IN-27 IN-12 IN-28 IN-13 IN-29 IN-14 IN-30 IN-15 IN-31 L2-0 L2-1 1771-WN Swing Arm From 1771-IAN Conversion Module Installation and Application Considerations The input delay times for the 1771-IAN module versus 1756-IA32 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IAN 10ms (+/-7ms) 20ms (+/-15ms) 1756-IA32 10ms max (plus selectable filter) 8ms max (plus selectable filter) The 1771-IAN has 4 groups(allowing 4 seperate power supplies) and the 1756-IA32 has 2 groups. This module/cable combination ties Groups 0 & 1 from the 1771-IAN to Group 0 on the 1756-IA32 and it ties Groups 2 & 3 from the 1771-IAN to Group 1 on the 1756-IA32. Field wiring modification must be made to accommodate this if multiple supplies were used. If 4 supplies were used, 2 must be removed. Refer to your 1771-IAN and 1756-IA32 Installation Manual wiring schematics and diagrams for more details. 22 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IB to 1756-IB16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD007 + - Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-1 A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XE 1756-IB16 10 9 1 2 3 4 5 6 7 8 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “A” 11 12 13 14 15 16 17 18 20 19 CABLE “B” GND-0 GND-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 GND-1 GND-1 Conversion Module 1492-CM1771-LD007 + - Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-1 1771-WA Swing Arm From 1771-IB A 0 1 2 3 4 5 6 7 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IB16 RTB. Recommended cable lengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths. The input delay times for the 1771-IB module versus the 1756-IB16 module are as follows: 1771-IB 1756-IB16 w/ 1492-C005005XE a) Off-to-On Delay 24ms (+/-10ms) 1ms max (plus selectable filter) b) On-to-Off Delay 24ms (+/-10ms) 2ms max (plus selectable filter) The 1771-IB module is rated 24V DC. The 1756-IB16 module is rated 10 - 31V DC only. Refer to your 1771-IB and 1756-IB16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-995 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 23 Wiring Diagrams - Digital Inputs 1771-IBD to 1756-IB16 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD001 Terminal A Terminal B Terminal C Terminal D Input 00 Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Input 17 Terminal E + - Cable 1492-CONCAB005X A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green 1756-IB16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 GND-0 GND-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 GND-1 GND-1 1771-WH Swing Arm From 1771-IBD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IB16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The input delay times for the 1771-IBD module versus the 1756-IB16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IBD 1ms 1ms 1756-IB16 w/ 1492-CONCAB005X 1ms (plus selectable filter) 2ms (plus selectable filter) Refer to your 1771-IBD and 1756-IB16 Installation Manual wiring Schematics and diagrams for more details. [Reference Doc: 41170-926 (Version 02)] 24 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IBN to 1756-IB32 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD003 + - dc Common 0 dc Common 2 10 30 Input 00 Input 00 Input 01 Input 01 Input 02 Input 02 Input 03 Input 03 Input 04 Input 04 Input 05 Input 05 Input 06 Input 06 Input 07 Input 07 Input 10 Input 10 Input 11 Input 11 Input 12 Input 12 Input 13 Input 13 Input 14 Input 14 Input 15 Input 15 Input 16 Input 16 Input 17 Input 17 dc Common 0 dc Common 1 dc Common 1 dc Common 2 dc Common 3 dc Common 3 1 21 2 22 3 23 4 24 5 25 6 26 7 27 8 28 11 31 12 32 13 33 14 34 15 35 16 36 17 37 18 38 9 19 20 29 39 40 Cable 1492-CONCAB005Z 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue 1756-IB32 18 36 1 19 2 20 3 21 4 22 5 23 6 24 7 25 8 26 9 27 10 28 11 29 12 30 13 31 14 32 15 33 16 34 17 35 GND-0 GND-1 IN-0 IN-16 IN-1 IN-17 IN-2 IN-18 IN-3 IN-19 IN-4 IN-20 IN-5 IN-21 IN-6 IN-22 IN-7 IN-23 IN-8 IN-24 IN-9 IN-25 IN-10 IN-26 IN-11 IN-27 IN-12 IN-28 IN-13 IN-29 IN-14 IN-30 IN-15 IN-31 GND-0 GND-1 1771-WN Swing Arm From 1771-IBN Conversion Module Installation and Application Considerations The input delay times for the 1771-IBN module versus 1756-IB32 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IBN 6ms (+/-2ms) 6ms (+/-2ms) 1756-IB32 1ms (plus selectable filter) 1ms (plus selectable filter) The 1771-IBN has 4 groups(allowing 4 seperate power supplies) and the 1756-IB32 has 2 groups. This module/cable combination ties Groups 0 & 1 from the 1771-IBN to Group 0 on the 1756-IB32 and it ties Groups 2 & 3 from the 1771-IBN to Group 1 on the 1756-IB32. Field wiring modification must be made to accommodate this if multiple supplies were used. If 4 supplies were used, 2 must be removed. Refer to your 1771-IBN and 1756-IB32 Installation Manual wiring schematics and diagrams for more details. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 25 Wiring Diagrams - Digital Inputs 1771-IC to 1756-IC16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD007 + - Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-1 A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XE 1756-IC16 10 9 1 2 3 4 5 6 7 8 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “A” 11 12 13 14 15 16 17 18 20 19 CABLE “B” GND-0 GND-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 GND-1 GND-1 Conversion Module 1492-CM1771-LD007 + - Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-1 A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IC16 RTB. Recommended cable lengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths. The input delay times for the 1771-IC module versus the 1756-IC16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IC 12ms (+/-7ms) 20ms (+/-7ms) 1756-IC16 w/ 1492-C005005XE 1ms max (plus selectable filter) 4ms max (plus selectable filter) The 1771-IC module is rated 42 to 56V DC. The 1756-IC16 module is rated 42 to 56V DC only. Refer to your 1771-IC and 1756-IC16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-996 (Version 00)] 26 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-ICD to 1756-IC16 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD001 + -- Terminal A Terminal B Terminal C Terminal D Input 00 Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Input 17 Terminal E Cable 1492-CONCAB005X A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green 1756-IC16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 RTN RTN IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 RTN RTN 1771-WH Swing Arm From 1771-ICD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IC16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The input delay times for the 1771-ICD module versus the 1756-IC16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-ICD 6ms (+/-2ms) 20ms (+/-1ms) 1756-IC16 w/ 1492-CONCAB005X 1ms max (plus selectable filter) 4ms max (plus selectable filter) The 1771-ICD module is rated 20V to 60V AC or DC. The 1756-IC16 module is rated 30V to 60V DC. Refer to your 1771-ICD and 1756-IC16 Installation Manual wiring schematics and diagrams for more details. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 27 Wiring Diagrams - Digital Inputs 1771-ID to 1756-IA16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD012 JMP0 3 N.C. N.O. 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 2 L1 L2 LOAD L1-0 L2-0 L1-1 L2-1 L1-2 L2-2 L1-3 L2-3 L1-4 L2-4 L1-5 L2-5 1771-WD Swing Arm From 1771-ID 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-C005005XL Blue L2 LOAD 1 2 3 4 5 6 7 8 9 10 11 12 White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red L1-0 L2-0 L1-1 L2-1 L1-2 L2-2 L1-3 L2-3 L1-4 L2-4 L1-5 L2-5 Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green CABLE”B” White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue Conversion Module 1492-CM1771-LD012 L1-6 L2-6 L1-7 L2-7 L1-8 L2-8 L1-9 L2-9 L1-10 L2-10 L1-11 L2-11 1771-WD Swing Arm From 1771-ID 1 2 3 4 5 6 7 8 9 10 11 12 JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 L1 1756-IA16I CABLE”A” Orange 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 25 26 27 28 29 30 31 32 33 34 35 36 13 14 15 16 17 18 19 20 21 22 23 24 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED L1-6 L2-6 L1-7 L2-7 L1-8 L2-8 L1-9 L2-9 L1-10 L2-10 L1-11 L2-11 Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IA16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The input delay times for the 1771-ID module versus the 1756-IA16I module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-ID 24ms (+/-10ms) 24ms (+/-10ms) 1756-IA16I w/ 1492-C005005XL 10ms max (plus selectable filter) 8ms max (plus selectable filter) The 1771-ID module had a jumper selection of N.O. and N.C. outputs. The 1756-IA16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-ID jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-ID and 1756-IA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 28 [Reference Doc: 41170-993 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-ID01 to 1756-IM16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD012 L1 L2 LOAD 1771-WD Swing Arm From 1771-ID01 L1-0 L2-0 L1-1 L2-1 L1-2 L2-2 L1-3 L2-3 L1-4 L2-4 L1-5 L2-5 1 2 3 4 5 6 7 8 9 10 11 12 JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-C005005XL Blue L1 LOAD 1771-WD Swing Arm From 1771-ID01 1 2 3 4 5 6 7 8 9 10 11 12 White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red L1-0 L2-0 L1-1 L2-1 L1-2 L2-2 L1-3 L2-3 L1-4 L2-4 L1-5 L2-5 Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green CABLE”B” White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue Conversion Module 1492-CM1771-LD012 L1-6 L2-6 L1-7 L2-7 L1-8 L2-8 L1-9 L2-9 L1-10 L2-10 L1-11 L2-11 1 2 3 4 5 6 7 8 9 10 11 12 JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 L2 1756-IM16I CABLE”A” Orange 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 25 26 27 28 29 30 31 32 33 34 35 36 13 14 15 16 17 18 19 20 21 22 23 24 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED L1-6 L2-6 L1-7 L2-7 L1-8 L2-8 L1-9 L2-9 L1-10 L2-10 L1-11 L2-11 Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IM16I RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion The input delay times for the 1771-IM module versus the 1756-IM16I module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-ID01 20ms (+/-10ms) 20ms (+/-10ms) 1756-IM16I w/ 1492-C005005XL 10ms max (plus selectable filter) 8ms max (plus selectable filter) The 1771-ID01module had a jumper selection of N.O. and N.C. outputs. The 1756-IM16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-ID01 jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-ID01 and 1756-IM16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-015 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 29 Wiring Diagrams - Digital Inputs 1771-ID16 to 1756-IA16I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD004 L2 L1 L2-0 Input 0 L2-1 Input 1 L2-2 Input 2 L2-3 Input 3 L2-4 Input 4 L2-5 Input 5 L2-6 Input 6 L2-7 Input 7 L2-10 Input 10 L2-11 Input 11 L2-12 Input 12 L2-13 Input 13 L2-14 Input 14 L2-15 Input 15 L2-16 Input 16 L2-17 Input 17 Not used Not used Not used Not used Not used Not used Not used Not used 2 1 4 3 6 5 8 7 12 11 14 13 16 15 18 17 22 21 24 23 26 25 28 27 32 31 34 33 36 35 38 37 9 10 19 20 29 30 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-IA16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L2-0 IN-0 L2-1 IN-1 L2-2 IN-2 L2-3 IN-3 L2-4 IN-4 L2-5 IN-5 L2-6 IN-6 L2-7 IN-7 L2-8 IN-8 L2-9 IN-9 L2-10 IN-10 L2-11 IN-11 L2-12 IN-12 L2-13 IN-13 L2-14 IN-14 L2-15 IN-15 1771-WN Swing Arm From 1771-ID16 Conversion Module Installation and Application Considerations The input delay times for the 1771-ID16 module versus 1756-IA16I module are as follows: 1771-ID16 1756-IA16I a) Off-to-On Delay 0.57ms 10ms max (plus selectable filter) b) On-to-Off Delay 9ms or 18ms (selectable) 8ms max (plus selectable filter) The 1771-ID16 module is rated 74V to 138V AC and105V to 138V DC. The 1756-IA16I is rated 79V to 132V AC. If the input source voltage is DC use a 1756-IH16I with this conversion module. Refer to your 1771-ID16 and 1756-IA16I Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-931 (Version 02)] 30 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-ID16 to 1756-IH16I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD004 + L2-0 Input 0 L2-1 Input 1 L2-2 Input 2 L2-3 Input 3 L2-4 Input 4 L2-5 Input 5 L2-6 Input 6 L2-7 Input 7 L2-10 Input 10 L2-11 Input 11 L2-12 Input 12 L2-13 Input 13 L2-14 Input 14 L2-15 Input 15 L2-16 Input 16 L2-17 Input 17 Not used Not used Not used Not used Not used Not used Not used Not used 2 1 4 3 6 5 8 7 12 11 14 13 16 15 18 17 22 21 24 23 26 25 28 27 32 31 34 33 36 35 38 37 9 10 19 20 29 30 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-IH16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 GND-0 IN-0 GND-1 IN-1 GND-2 IN-2 GND-3 IN-3 GND-4 IN-4 GND-5 IN-5 GND-6 IN-6 GND-7 IN-7 GND-8 IN-8 GND-9 IN-9 GND-10 IN-10 GND-11 IN-11 GND-12 IN-12 GND-13 IN-13 GND-14 IN-14 GND-15 IN-15 1771-WN Swing Arm From 1771-ID16 Conversion Module Installation and Application Considerations The input delay times for the 1771-ID16 module versus 1756-IH16I module are as follows: 1771-ID16 1756-IH16I a) Off-to-On Delay 0.57ms 2ms max (plus selectable filter) b) On-to-Off Delay 9ms or 18ms (selectable) 6ms max (plus selectable filter) The 1771-ID16 module is rated 74V to 138V AC and105V to 138V DC. The 1756-IH16I is rated 90V to 146V DC. If the input source voltage is AC use a 1756-IA16I with this conversion module. Refer to your 1771-ID16 and 1756-IH16I Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-932 (Version 02)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 31 Wiring Diagrams - Digital Inputs 1771-IG to 1756-IG16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LA003 + DC Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Common + 5V DC SUPPLY - Input Device + - A 0 1 2 3 4 5 6 7 B 1771-WC Swing Arm From 1771-IG 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 Red/White Cable 1492-C005005XS CABLE”A” Green/Black/White Red/Black/White White/Black/Red Black/White/Red Orange/Green Blue/Red Orange/Red White/Red Black/Red 1756-IG16 10 1 2 3 4 5 6 7 8 9 20 11 12 13 14 15 16 17 18 19 + DC -0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 - DC -0 + DC -1 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 - DC -1 SH Conversion Module 1492-CM1771-LA003 + DC Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Common + 5V DC SUPPLY - Input Device + - 1771-WC Swing Arm From 1771-IG A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 Red/White Green/Black/White Red/Black/White White/Black/Red Black/White/Red Orange/Green Blue/Red Orange/Red White/Red Black/Red CABLE”B” SH Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IG16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. The input delay times for the 1771-IG module versus the 1756-IG16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IG 1ms (+/-10ms) 1ms (+/-10ms) 1756-IG16 w/ 1492-C005005XS 270ms max (plus selectable filter) 390ms max (plus selectable filter) The 1771-IG module is rated 5V DC TTL INPUT MODULE. The 1756-IG16 module is rated 5V DC TTL INPUT MODULE only. Refer to your 1771-IG and 1756-IG16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 32 [Reference Doc: 41171-027 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IGD to 1756-IG16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD006 + dc + dc + - - DC Input Device + + dc + dc Input 00 Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 08 Input 09 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 - dc Cable 1492-CONCAB005X A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 E 1756-IG16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green DC-0+ RTN OUT-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 DC-1+ RTN OUT-1 1771-WH, WHF, WHFB Swing Arm From 1771-IGD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IG16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-IGD module output current limits versus 1756-IG16 limits are as follows: a) Current/Point b) Current/Module 1771-IGD 122mA 500mA 1756-IG16 w/ 1492-CONCAB005X 110mA 110mA The 1771-IGD is rated 5V DC. The 1756-IG16 is rated 4.5V to 5.5V DC. Refer to your 1771-IGD and 1756-IG16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-004 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 33 Wiring Diagrams - Digital Inputs 1771-IH to 1756-IC16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. WARNING IMPORTANT Conversion Module 1492-CM1771-LD007 + - Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-0 A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XE 1756-IC16 10 9 1 2 3 4 5 6 7 8 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “A” CABLE “B” 11 12 13 14 15 16 17 18 20 19 GND-0 GND-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 GND-1 GND-1 Conversion Module 1492-CM1771-LD007 + - Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-1 1771-WA Swing Arm From 1771-IH A 0 1 2 3 4 5 6 7 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IC16 RTB. Recommended cable lengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths. The input delay times for the 1771-IH module versus the 1756-IC16 module are as follows: 1771-IH 1756-IC16 w/ 1492-C005005XE a) Off-to-On Delay 15ms (+/-7ms) 1ms max (plus selectable filter) b) On-to-Off Delay 15ms (+/-7ms) 4ms max (plus selectable filter) The 1771-IH module is rated 24V - 48V DC. The 1756-IC16 module is rated 30V - 60V DC. Refer to your 1771-IH and 1756-IC16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-997 (Version 00)] 34 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IM to 1756-IM16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD007 L1 L2 Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 L2 A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XH Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “A” 17 19 21 23 25 27 29 31 18 20 Conversion Module 1492-CM1771-LD007 L1 L2 Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 L2 1771-WA Swing Arm From 1771-IM A 0 1 2 3 4 5 6 7 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-IM16I 2 4 1 3 5 7 9 11 13 15 6 8 10 12 14 16 22 24 26 28 30 32 Black White Red Green Orange Blue L2-0 L2-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 L2-0 L2-0 L2-0 L2-0 L2-0 L2-0 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 L2-1 L2-1 L2-1 L2-1 L2-1 L2-1 L2-1 L2-1 White/Black Red/Black Green/Black Orange/Black CABLE “B” Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IM16I RTB. Recommended cable lengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths. The input delay times for the 1771-IM module versus the 1756-IM16I module are as follows: 1771-IM 1756-IM16I w/ 1492-C005005XH a) Off-to-On Delay 20ms (+/-6ms) 10ms max (plus selectable filter) b) On-to-Off Delay 20ms (+/-6ms) 8ms max (plus selectable filter) The 1771-IM module is rated 220V to 240V AC. The 1756-IM16I module is rated 159 - 265V AC only. Refer to your 1771-IM and 1756-IM16I Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-990 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 35 Wiring Diagrams - Digital Inputs 1771-IMD to 1756-IM16I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD002 Terminal A Terminal B Terminal C Terminal D Input 00 L1 L2 A B C D 00 Input 01 01 Input 02 02 Input 03 03 Input 04 04 Input 05 05 Input 06 06 Input 07 07 Input 10 10 Input 11 11 Input 12 12 Input 13 13 Input 14 14 Input 15 15 Input 16 16 Input 17 17 Terminal E 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-IM16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L2-0 IN-0 L2-1 IN-1 L2-2 IN-2 L2-3 IN-3 L2-4 IN-4 L2-5 IN-5 L2-6 IN-6 L2-7 IN-7 L2-8 IN-8 L2-9 IN-9 L2-10 IN-10 L2-11 IN-11 L2-12 IN-12 L2-13 IN-13 L2-14 IN-14 L2-15 IN-15 E 1771-WH Swing Arm From 1771-IMD Conversion Module Installation and Application Considerations The input delay times for the 1771-IMD module versus 1756-IM16I module are as follows: 1771-IMD 1756-IM16I a) Off-to-On Delay 15ms (+/-8ms) 10ms (plus selectable filter) b) On-to-Off Delay 172ms (+/-56ms) 8ms (plus selectable filter) The 1771-IMD module is rated 184V AC to 250V AC and 166V-230V DC. The 1756-IM16I module is rated 159V to 265V AC. A1756 input module with an equivalent DC voltage range to convert the 1771-IMD is not available. Refer to your 1771-IMD and 1756-IM16I Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-928 (Version 02)] 36 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IN to 1756-IN16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. WARNING IMPORTANT Conversion Module 1492-CM1771-LD007 + - Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-1 A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XE 1756-IN16 10 9 1 2 3 4 5 6 7 8 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “A” CABLE “B” 11 12 13 14 15 16 17 18 20 19 L2-0 L2-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 L2-1 L2-1 Conversion Module 1492-CM1771-LD007 + - Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 L2 1771-WA Swing Arm From 1771-IN A 0 1 2 3 4 5 6 7 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IN16 RTB. Recommended cable lengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths. The input delay times for the 1771-IN module versus the 1756-IN16 module are as follows: 1771-IN 1756-IN16 w/ 1492-C005005XE a) Off-to-On Delay 18ms (+/-10ms) 10ms max (plus selectable filter) b) On-to-Off Delay 18ms (+/-10ms) 10ms max (plus selectable filter) The 1771-IN module is rated 24V AC. The 1756-IN16 module is rated 24V AC only. Refer to your 1771-IN and 1756-IN16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-998 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 37 Wiring Diagrams - Digital Inputs 1771-IND to 1756-IN16 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD001 L1 L2 Terminal A Terminal B Terminal C Terminal D Input 00 Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Input 17 Terminal E A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-IN16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green L2-0 L2-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 L2-1 L2-1 1771-WH Swing Arm From 1771-IND Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IN16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The input delay times for the 1771-IND module versus the 1756-IN16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IND 35ms (+/-10ms) @24V AC 45ms (+/-15ms) 1756-IN16 w/ 1492-CONCAB005X 10ms max (plus selectable filter) 10ms max (plus selectable filter) The 1771-IND module is rated 24V AC or DC. The 1756-IN16 module is rated 10V to 30V AC. Refer to your 1771-IND and 1756-IN16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-002 (Version 00)] 38 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IND1 to 1756-IN16 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD001 L1 L2 Terminal A Terminal B Terminal C Terminal D Input 00 Input 01 Input 02 Input 03 Input 04 Input 05 Input 06 Input 07 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Input 16 Input 17 Terminal E A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-IN16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green L2-0 L2-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 L2-1 L2-1 1771-WH Swing Arm From 1771-IND1 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IN16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The input delay times for the 1771-IND1 module versus the 1756-IN16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IND1 25ms (+/-5ms) @48V AC 35ms (+/-10ms) 1756-IN16 w/ 1492-CONCAB005X 10ms max (plus selectable filter) 10ms max (plus selectable filter) The 1771-IND1 module is rated 48V AC. The 1756-IN16 module is rated 10V to 30V AC. Refer to your 1771-IND1 and 1756-IN16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-003 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 39 Wiring Diagrams - Digital Inputs 1771-IQ to 1756-IB16I— Sinking IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Cable 1492-C005005XK Conversion Module 1492-CM1771-LD007 + _ Not used IN 0 IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 L2 - 0 A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IQ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “A” 17 19 21 23 25 27 29 31 18 20 22 24 26 28 30 32 Conversion Module 1492-CM1771-LD007 + _ Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 L2 - 1 1771-WA Swing Arm From 1771-IQ A 0 1 2 3 4 5 6 7 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-IB16I 2 4 1 3 5 7 9 11 13 15 6 8 10 12 14 16 L2-0 L2-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 L2-0 L2-0 L2-0 L2-0 L2-0 L2-0 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 L2-1 L2-1 L2-1 L2-1 L2-1 L2-1 L2-1 L2-1 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “B” Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IB16I RTB. Recommended cable lengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths. The input delay times for the 1771-IQ module versus the 1756-IB16I module are as follows: 1771-IQ 1756-IB16I w/ 1492-C005005XK a) Off-to-On Delay 12ms (+/-14ms) 1ms max (plus selectable filter) b) On-to-Off Delay 12ms (+/-7ms) 4ms max (plus selectable filter) The 1771-IQ module is rated 5V to 30V DC. The 1756-IB16I module is rated 10V to 30V DC only. Refer to your 1771-IQ and 1756-IB16I Installation Manual wiring schematics and diagrams for more details. For Sourcing applications use 1492-CM1771-LD014. [Reference Doc: 41170-992 (Version 00)] 40 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IQ to 1756-IB16I— Sourcing There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD0014 DC+ GND 00 GND 01 GND 02 GND 03 A 0 1 2 3 + - GND 04 GND 05 GND 06 GND 07 DC - LOAD 4 5 6 7 B 1771-WA Swing Arm From 1771-IQ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XJ White 2 4 6 8 1 3 5 7 9 11 13 15 10 12 14 16 Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green 34 A 0 1 2 3 + - GND -12 GND -13 GND -14 GND -15 DC - LOAD 4 5 6 7 B 1771-WA Swing Arm From 1771-IQ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 GND-0 GND-1 GND-2 GND-3 IN - 0 IN - 1 IN - 2 IN - 3 IN - 4 IN - 5 IN - 6 IN - 7 GND-4 GND-5 GND-6 GND-7 GND-15 CABLE”A” 18 20 22 24 17 19 21 23 25 27 29 31 26 28 30 32 33 35 36 Conversion Module 1492-CM1771-LD0014 DC + GND 08 GND 09 GND -10 GND -11 1756-IB16I Black Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black GND-8 OUT-9 OUT-10 OUT-11 IN - 8 IN - 9 IN - 10 IN - 11 IN - 12 IN - 13 IN - 14 IN - 15 GND-12 GND-13 GND-14 GND-15 NOT-USED NOT-USED NOT-USED Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green CABLE”B” Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IB16I RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. The input delay times for the 1771-IQ module versus the 1756-IB16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IQ 12ms (+/-14ms) 12ms (+/-14ms) 1756-IB16I w/1492-C005005XJ 1ms max (plus selectable filter) 4ms max (plus selectable filter) The 1771-IQ module is rated 5V to 30V DC. The 1756-IB16I module is rated 10V to 30V SOURCING DC only. Refer to your 1771-IQ and 1756-IB16I Installation Manual wiring schematics and diagrams for more details. For Sinking applications use 1492-CM1771-LD007. [Reference Doc: 41170-991 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41 Wiring Diagrams - Digital Inputs 1771-IQ16 to 1756-IB16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD004 Sinking Input Example + Sourcing Input Example Gnd-0 Input 0 Gnd-1 Input 1 Gnd-2 Input 2 Gnd-3 Input 3 Gnd-4 Input 4 Gnd-5 Input 5 Gnd-6 Input 6 Gnd-7 Input 7 Gnd-10 Input 10 Gnd-11 Input 11 Gnd-12 Input 12 Gnd-13 Input 13 Gnd-14 Input 14 Gnd-15 Input 15 Gnd-16 Input 16 Gnd-17 Input 17 Not used Not used Not used Not used Not used Not used Not used Not used 2 1 4 3 6 5 8 7 12 11 14 13 16 15 18 17 22 21 24 23 26 25 28 27 32 31 34 33 36 35 38 37 9 10 19 20 29 30 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-IB16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 Gnd-0 IN-0 Gnd-1 IN-1 Gnd-2 IN-2 Gnd-3 IN-3 Gnd-4 IN-4 Gnd-5 IN-5 Gnd-6 IN-6 Gnd-7 IN-7 Gnd-8 IN-8 Gnd-9 IN-9 Gnd-10 IN-10 Gnd-11 IN-11 Gnd-12 IN-12 Gnd-13 IN-13 Gnd-14 IN-14 Gnd-15 IN-15 + 1771-WN Swing Arm From 1771-IQ16 Conversion Module Installation and Application Considerations The input delay times for the 1771-IQ16 module versus 1756-IB16I module are as follows: 1771-IQ16 1756-IB16I a) Off-to-On Delay 0.57ms 1ms max (plus selectable filter) b) On-to-Off Delay 0.57ms 4ms max (plus selectable filter) Both the 1771-IQ16 and 1756-IB16I allow operation with sourcing inputs. Refer to installation Instructions for details. Refer to your 1771-IQ16 and 1756-IH16I Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-933 (Version 02)] 42 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IT to 1756-IB16 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD007 Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-1 + - A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XE 1756-IB16 10 9 1 2 3 4 5 6 7 8 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black CABLE “A” 11 12 13 14 15 16 17 18 20 19 CABLE “B” GND-0 GND-0 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 GND-1 GND-1 Conversion Module 1492-CM1771-LD007 Not used Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 GND-1 + - A 0 1 2 3 4 5 6 7 B 1771-WA Swing Arm From 1771-IT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IB16 RTB. Recommended cable lengths of 0.5 M / 0.5 M are shown. See table 2 for other lengths. The input delay times for the 1771-IT module versus the 1756-IB16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IT 0.6ms (+/-0.2ms) 0.6ms (+/-0.2ms) 1756-IB16 w/ 1492-C005005XE 1ms max (plus selectable filter) 2ms max (plus selectable filter) The 1771-IT module is rated 24V DC. The 1756-IB16 module is rated 24V DC only. Refer to your 1771-IT and 1756-IB16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-999 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 43 Wiring Diagrams - Digital Inputs 1771-IV to 1756-IV16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD014 +DC-0 INPUT 00 INPUT 01 INPUT 02 INPUT 03 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 A 0 1 2 3 + - LOAD INPUT 04 INPUT 05 INPUT 06 INPUT 07 -DC-0 4 5 6 7 B 1771-WA Swing Arm From 1771-IV Cable 1492-C005005XG Black White 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 A 0 1 2 3 + - LOAD INPUT 12 INPUT 13 INPUT 14 INPUT 15 -DC-1 4 5 6 7 B 1771-WA Swing Arm From 1771-IV 1 2 3 4 9 10 Red Green Orange Blue White/Black Red/Black Green/Black IN-0 IN-1 IN-2 IN-3 +DC-0 +DC-0 Orange/Black Blue/Black Black/White Red/White Green/White 5 6 7 8 Blue/White Black/Red White/Red Orange/Red Blue/Red IN-4 IN-5 IN-6 IN-7 Red/Green Cable B Conversion Module 1492-CM1771-LD014 +DC-1 INPUT 08 INPUT 09 INPUT 10 INPUT 11 1756-IV16 Cable A 11 12 13 14 19 20 IN-8 IN-9 IN-10 IN-11 +DC-1 +DC-1 Black White Red Green Orange Blue White/Black Red/Black 15 16 17 18 IN-12 IN-13 IN-14 IN-15 Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-IV16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. The input delay times for the 1771-IV module versus the 1756-IV16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-IV 15ms (+/-7ms) 15ms (+/-7ms) 1756-IV16 w/1492-C005005XG 1ms max (plus selectable filter) 2ms max (plus selectable filter) The 1771-IV module is rated 12 To 24V DC. The 1756-IV16 module is rated 10V To 30V DC only. Refer to your 1771-IV and 1756-IV16 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-989 (Version 00)] 44 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Inputs 1771-IVN to 1756-IV32 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD005 + 10-30V dc (0) 10-30V dc (2) 2 22 Input 00 Input 00 Input 01 Input 01 Input 02 Input 02 Input 03 Input 03 Input 04 Input 04 Input 05 Input 05 Input 06 Input 06 Input 07 Input 07 Input 10 Input 10 Input 11 Input 11 Input 12 Input 12 Input 13 Input 13 Input 14 Input 14 Input 15 Input 15 Input 16 Input 16 Input 17 Input 17 10-30V dc (0) 10-30V dc (1) 10-30V dc (1) 10-30V dc (2) 10-30V dc (3) 10-30V dc (3) 3 23 4 24 5 25 6 26 7 27 8 28 9 29 10 30 13 33 14 34 15 35 16 36 17 37 18 38 19 39 20 40 1 11 12 21 31 32 Cable 1492-CONCAB005Z 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue 1756-IV32 18 36 1 19 2 20 3 21 4 22 5 23 6 24 7 25 8 26 9 27 10 28 11 29 12 30 13 31 14 32 15 33 16 34 17 35 DC-0 (+) DC-1 (+) IN-0 IN-16 IN-1 IN-17 IN-2 IN-18 IN-3 IN-19 IN-4 IN-20 IN-5 IN-21 IN-6 IN-22 IN-7 IN-23 IN-8 IN-24 IN-9 IN-25 IN-10 IN-26 IN-11 IN-27 IN-12 IN-28 IN-13 IN-29 IN-14 IN-30 IN-15 IN-31 DC-0 (+) DC-1 (+) 1771-WN Swing Arm From 1771-IVN Conversion Module Installation and Application Considerations The input delay times for the 1771-IVN module versus 1756-IV32 module are as follows: 1771-IVN 1756-IV32 a) Off-to-On Delay 6ms (+/-2ms) 1ms (plus selectable filter) b) On-to-Off Delay 6ms (+/-2ms) 2ms (plus selectable filter) The 1771-IVN has 4 groups (allowing 4 seperate power supplies) and the 1756-IV32 has 2 groups. This module/cable combination ties Groups 0 & 1 from the 1771-IVN to Group 0 on the 1756-IV32 and it ties Groups 2 & 3 from the 1771-IVN to Group 1 on the 1756-IV32.Field wiring modification must be made to accommodate this if multiple supplies were used. If 4 supplies were used, 2 must be removed. Refer to your 1771-IVN and 1756-IV32 Installation Manual wiring schematics and diagrams for more details. [Reference Doc: 41170-934 (Version 02)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 45 Wiring Diagrams - Digital Inputs Notes: 46 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OA to 1756-OA8E IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD014 L1 Output 00 Output 01 Output 02 Output 03 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 A 0 1 2 3 L1 L2 LOAD Output 04 Output 05 Output 06 Output 07 L2 Cable 1492-CONCAB005U 4 5 6 7 B 1756-OA8E 2 1 3 5 7 9 4 6 8 10 12 14 16 18 11 13 15 17 19 20 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Not Used L2-0 OUT-0 OUT-1 OUT-2 OUT-3 L1-0 L1-0 L1-0 L1-0 L1-1 L1-1 L1-1 L1-1 OUT-4 OUT-5 OUT-6 OUT-7 L2-1 L1-1 1771-WA Swing Arm From 1771-OA Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA8E RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OA module output current limits versus 1756-OA8E limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Pt 1771-OA 1.5A 6A 4A for 8.3ms 1756-OA8E w/ 1492-CONCAB005U 2A 4A @ 60°C 20A for 43 ms The 1771-OA has eight (8) 2A, 250V fuses - 1 per output. The 1756-OA8E is electronically fused per point. Refer to the 1756 OA8E Installation Manual for details on electronic fusing. Refer to your 1771-OA and 1756-OA8E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-943 (Version 01)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 47 Wiring Diagrams - Digital Outputs 1771-OAD to 1756-OA16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD006 L1 L2 Output Device L1 L1 L1 L1 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 L2 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OA16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green L1-0 L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1 L2-1 1771-WH, WHF, WHFB Swing Arm From 1771-OAD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OAD module output current limits versus 1756-OA16 limits are as follows: 1771-OAD 2A 8A 25A for 100ms a) Current/Point b) Current/Module c) Surge Current/point 1756-OA16 w/ 1492-CONCAB005X 0.5A 4A 5A for 43ms The L2 terminal (Terminal E) on the 1771-OAD module was an optional connection, but it is required for the 1756-OA16. This connection must be added if it was not connected. The 1771-OAD is rated 10V to 138V AC. The 1756-OA16 is rated 74V to 256V AC. Refer to your 1771-OAD and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 48 [Reference Doc: 41170-935 (Version 01)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OAN to 1756-OA16 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD013 1 11 10 20 2 3 4 5 6 7 8 9 12 13 14 15 16 17 18 19 L1 L1 L2 L2 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 21 31 30 40 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 Cable 1492-CONCAB005S3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red 1756-OA16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 L1-0 L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1 L2-1 MODULE A L2 L1 L1 L2 L2 Output 00 Output 01 Output Output 02 Device Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 1756-OA16 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 1771-WN Swing Arm From 1771-OAN L1-0 L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1 L2-1 MODULE B L1 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to two 1756-OA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OAN module output current limits versus 1756-OA16 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OAN 1A 8A (32 pts) 10A for 25ms 1756-OA16 w/ 1492-CONCAB005S3 0.5A 2A (16 pts) 5A for 43ms The 1771-OAN has 4 groups (allowing 4 separate power supplies). This module/cable combination ties all 4 groups from the 1771-OAN together. Field wiring modification must be made to accommodate this if mulitple supplies were used. If more than 1 supply was used, all but 1 of the power supplies must be removed. The 1771-OAN did not allow connections for L2, however the 1756-OA16 requires an L2 connection for proper operation. The 1771-OAN did not use terminals 10, 20, 30, 40. These terminals have been reassigned for an L2 connection in this application. The installer must rewire L2 to one of these terminals. Refer to your 1771-OAN and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. This configuration uses two (2) 1756-OA16 output modules to replace a single 1771-OAN output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. [Reference Doc: 41170-942 (Version 02)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 49 Wiring Diagrams - Digital Outputs 1771-OB to 1756-OB16D WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD014 L1 Output 00 Output 01 Output 02 Output 03 A 0 1 2 3 + - LOAD Output 04 Output 05 Output 06 Output 07 L2 1771-WA Swing Arm From 1771-OB 4 5 6 7 B Black A 0 1 2 3 + - Output 04 Output 05 Output 06 Output 07 L2 1771-WA Swing Arm From 1771-OB 4 5 6 7 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OB16D 16 1 3 5 7 2 4 6 8 10 12 14 White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White 9 11 13 15 16 Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green GND-0 OUT-0 OUT-1 OUT-2 OUT-3 +DC-0 +DC-0 +DC-0 +DC-0 +DC-0 +DC-0 +DC-0 OUT-4 OUT-5 OUT-6 OUT-7 GND-0 NOT USED CABLE”B” Conversion Module 1492-CM1771-LD014 L1 Output 00 Output 01 Output 02 Output 03 LOAD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XF CABLE”A” Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White 32 17 19 21 23 18 20 22 24 26 28 30 25 27 29 31 32 34 33 35 36 GND-1 OUT-8 OUT-9 OUT-10 OUT-11 +DC-1 +DC-1 +DC-1 +DC-1 +DC-1 +DC-1 +DC-1 OUT-12 OUT-13 OUT-14 OUT-15 GND-1 GND-1 NOT USED NOT USED ONT USED Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OB16D RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. The 1771-OB module output current limits versus 1756-OB16D limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OB 1.5A 6A 4A for 8.3ms 1756-OB16D w/ 1492-C005005XF 2A 4A @ 60°C 4A for 10ms The 1771-OB has eight (8) 2A, 250V fuses - 1 per output. The 1756-OB16D is a DIAGNOSTIC MODULE. Refer to the 1756-OB16D Installation Manual for details on diagnostics. Refer to your 1771-OB and 1756-OB16D Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 50 [Reference Doc: 41170-988 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OBD to 1756-OB16E WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD006 + dc + dc + dc + dc Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 + - - dc Output Device + L2 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OB16E 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green DC-0+ RTN OUT-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 DC-1+ RTN OUT-1 1771-WH, WHF, WHFB Swing Arm From 1771-OBD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OBD module output current limits versus 1756-OB16E limits are as follows: a) Current/Point b) Current/Module c) Surge Current/point 1771-OBD 2A 8A 4A for 10ms 1756-OB16E w/ 1492-CONCAB005X 1A 4A 2A for 10ms The 1771-OBD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch). The 1756-OB16E is electronically fused per group. Refer to the 1756-OB16E Installation Manual for details on electronic fusing. The 1771-OBD is rated 10V to 60V DC. The 1756-OB16E is rated 10V to 31.2V DC. If the load source voltage is greater than 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module. Refer to your 1771-OBD and 1756-OB16E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-936 (Version 01)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 51 Wiring Diagrams - Digital Outputs 1771-OBD to 1756-OC8 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. + - LOAD DC(+) DC(+) DC(+) DC(+) Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 DC(-) A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 Cable 1492-CONCAB005S1 1756-OC8 1 Black 2 DC-0(+) 2 White 1 OUT-0 3 Red 3 OUT-1 4 Green 5 OUT-2 5 Orange 7 OUT-3 9 4 6 8 10 12 14 16 18 11 13 15 17 19 20 RTN OUT-0 DC-0(+) DC-0(+) DC-0(+) RTN OUT-0 DC-1(+) DC-1(+) DC-1(+) DC-1(+) OUT-4 OUT-5 OUT-6 OUT-7 RTN OUT-1 RTN OUT-1 6 7 8 9 10 11 12 13 14 15 16 17 Blue 18 Orange/Red 19 20 21 22 23 Blue/Red White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red MODULE A Conversion Module 1492-CM1771-LD008F 1756-OC8 24 25 26 27 28 29 30 31 32 33 34 35 36 37 E 1771-WH, WHF, WHFB Swing Arm From 1771-OBD Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange White/Red/Blue 2 1 3 5 7 9 4 6 8 10 12 14 16 18 11 13 15 17 19 20 DC-0(+) OUT-0 OUT-1 OUT-2 OUT-3 RTN OUT-0 DC-0(+) DC-0(+) DC-0(+) RTN OUT-0 DC-1(+) DC-1(+) DC-1(+) DC-1(+) OUT-4 OUT-5 OUT-6 OUT-7 RTN OUT-1 RTN OUT-1 MODULE B IMPORTANT Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to two 1756-OC8 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OBD module output current limits versus 1756-OC8 limits are as follows: a) Current/Point b) Current /Module c) Surge Current /Point 1771-OBD 2A 8A 4A for 10ms 1756-OC8 w/ 1492-CONCAB005S1 2A 8A 4A for 10ms The 1771-OBD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch ). The 1756-OC8 is NOT fused ,as such a 2AG fuse clip and 10A fuse is provided on the 1492-CM1771-LD008F conversion module. The 1771-OBD is rated 10V to 60V DC. The 1756-OC8 is rated 30V to 60V DC. If the load source voltages is less than 30V DC, then use 1756-OB16E with the 1492-CM1771-LD006 conversion module. This configuration uses two(2) 1756-OC8 output modules to replace a single 1771-OBD output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. Refer to your 1771-OBD and 1756-OC8 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 52 [Reference Doc: 41170-937 (Version 01)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OBDS to 1756-OB16E There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD006 + dc + dc + - - dc Output Device + + dc + dc Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 - dc A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OB16E 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green DC-0+ RTN OUT-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 DC-1+ RTN OUT-1 1771-WH, WHF, WHFB Swing Arm From 1171-OBDS Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OB16E RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OBDS module output current limits versus 1756-OB16E limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OBDS 1A 8A 4A for 10ms 1756-OB16E w/ 1492-CONCAB005X 1A 8A 2A for 10ms The 1771-OBDS has a single 12A, 250V rectifier fuse (1/4 x 1-1/4 inch). The 1756-OB16E is electronically fused per group. Refer to the 1756-OB16E Installation Manual for details on electronic fusing. The 1771-OBDS is rated 10V to 40V DC. The 1756-OB16E is rated 10V to 31.2V DC. If the load source voltage is greater than 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module. Refer to your 1771-OBDS and 1756-OB16E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-005 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 53 Wiring Diagrams - Digital Outputs 1771-OBN to 1756-OB32 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. WARNING IMPORTANT Cable 1492-CONCAB005Zc Conversion Module 1492-CM1771-LD009F + LOAD 10-30V dc(0) 10-30V dc(1) 10-30V dc(2) 10-30V dc(3) Output 00 Output 00 Output 01 Output 01 Output 02 Output 02 Output 03 Output 03 Output 04 Output 04 Output 05 Output 05 Output 06 Output 06 Output 07 Output 07 Output 10 Output 10 Output 11 Output 11 Output 12 Output 12 Output 13 Output 13 Output 14 Output 14 Output 15 Output 15 Output 16 Output 16 Output 17 Output 17 Common 0 Common 1 Common 2 Common 3 1 11 21 31 2 22 3 23 4 24 5 25 6 26 7 27 8 28 9 29 12 32 13 33 14 34 15 35 16 36 17 37 18 38 19 39 10 20 30 40 1 2 Black 3 4 5 6 7 8 9 10 Red 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Blue/Black 25 26 27 28 29 30 31 32 33 34 35 36 37 White Green Orange Blue White/Black Red/Black Green/Black Orange/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Orange Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue 1756-OB32 18 36 DC-0(+) DC-1(+) 1 19 2 20 3 21 4 22 5 23 6 24 7 25 8 26 9 27 10 28 11 29 12 30 13 31 14 32 15 33 16 34 17 35 OUT-0 OUT-16 OUT-1 OUT-17 OUT-2 OUT-18 OUT-3 OUT-19 OUT-4 OUT-20 OUT-5 OUT-21 OUT-6 OUT-22 OUT-7 OUT-23 OUT-8 OUT-24 OUT-9 OUT-25 OUT-10 OUT-26 OUT-11 OUT-27 OUT-12 OUT-28 OUT-13 OUT-29 OUT-14 OUT-30 OUT-15 OUT-31 RTN OUT-0 RTN OUT-1 1771-WN Swing Arm From 1771-OBN Conversion Module Installation and Application Considerations cThe 1771-OBN module output current limits versus 1756-OB32 limits are as follows: 1771-OBN 1756-OB32w/1492-CONCAB005Z a) Current/Point 0.5A 0.35A @ 60˚C b) Current/Module 8A 6A @ 60˚C c) Surge Current/Point 2A for 10ms 1A for 10ms d The 1771-OBN has four (4) 4A, 250V rectifier fuses. The 1756-OB32 is NOT fused, as such four (4) 2AG fuse clips and 4A fuses are provided on the 1492-CM1771-LD009F conversion module. e The 1492-CONAB005Z is limited to 3A per pin. f The 1771-OBN has 4 groups (allowing 4 separate power supplies) and the 1756-OB32 has 2 groups. This module/cable combination ties Groups 0 & 1 from the 1771-OBN to Group 0 on the 1756-OB32 and Groups 2 & 3 from the 1771-OBN to Group 1 on the 1756-OB32. Field wiring modification must be made to accommodate this if multiple supplies were used. If 4 supplies were used, 2 must be removed. g Refer to your 1771-OBN and 1756-OB32 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 41170-938 (01) 54 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OC to 1756-OC8 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD014 +DC Output 00 Output 01 Output 02 Output 03 A 0 1 2 3 +DC -DC LOAD Output 04 Output 05 Output 06 Output 07 RTN 4 5 6 7 B Cable 1492-CONCAB005V 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OC8 9 10 1 3 5 7 2 4 6 8 12 14 16 18 11 13 15 17 19 20 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green RTN-0 RTN-0 OUT-0 OUT-1 OUT-2 OUT-3 +DC-0 +DC-0 +DC-0 +DC-0 +DC-1 +DC-1 +DC-1 +DC-1 OUT-4 OUT-5 OUT-6 OUT-7 RTN-1 RTN-1 1771-WA Swing Arm From 1771-OC Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OC8 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OC module output current limits versus 1756-OC8 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OC 1.5A 8A 4A for 1.0ms 1756-OC8 w/ 1492-CONCAB005V 2A 8A @ 60°C 4A for 10ms The 1771-OC has eight (8) 2A, 250V fuses - 1 per output. Refer to the 1756-OC8 Installation Manual for details. Refer to your 1771-OC and 1756-OC8 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-020 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 55 Wiring Diagrams - Digital Outputs 1771-OD to 1756-OA16I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation. In addition, refer to the current draw requirements of the existing loads for this configuration to ensure they are within the current ratings of the 1756 output module. CONVERSION MODULE 1492-CM1771-LD012 JMP0 L1 L2 LOAD 1771-WD Swing Arm From 1771-OD L1-0 L2-0 L1-1 L2-1 L1-2 L2-2 L1-3 L2-3 L1-4 L2-4 L1-5 L2-5 1 2 3 4 5 6 7 8 9 10 11 12 3 4 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1492-C005005XM 1 1756-OA16I CABLE”A” Orange Blue 2 1 4 3 6 5 8 7 10 9 12 11 White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green CABLE”B” White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue CONVERSION MODULE 1492-CM1771-LD012 L1 LOAD 1771-WD Swing Arm From 1771-OD L1-6 L2-6 L1-7 L2-7 L1-8 L2-8 L1-9 L2-9 L1-10 L2-10 L1-11 L2-11 1 2 3 4 5 6 7 8 9 10 11 12 JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 L2 L1-0 L2-0 L1-1 L2-1 L1-2 L2-2 L1-3 L2-3 L1-4 L2-4 L1-5 L2-5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 25 26 27 28 29 30 31 32 33 34 35 36 14 13 16 15 18 17 20 19 22 21 24 23 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED L1-6 L2-6 L1-7 L2-7 L1-8 L2-8 L1-9 L2-9 L1-10 L2-10 L1-11 L2-11 Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 This Bul. 1492 cable consists of 2 separate cables (cable “A” and “B”) wired to one 1756-IM16I RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. 2 The 1771-OD module output resistive current limits versus 1756-OA16I limits are as follows: (NOTE: for switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OD 1756-OA16I w/ 1492-CONCAB005XM a) Current/Point 0.2A @ 138V AC 2A @ 240V AC 1A @ 30V DC 2A @ 30V DC 0.25A@ 125V DC 0.25A @ 125V DC 2 The 1492-COO5005XM is limited to 3A per pin. 3 The 1771-OD module had a jumper selection of N.O. and N.C. outputs. The 1756-OA16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OD jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O.. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. 4 Refer to your 1771-OD and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 56 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41170-994 (01) Wiring Diagrams - Digital Outputs 1771-OD16 to 1756-OA16I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD010F Not Not Not Not L1 L2 Used Used Used Used L1-0 Output 0 LOAD L1-1 Output 1 L1-2 Output 2 L1-3 Output 3 L1-4 Output 4 L1-5 Output 5 L1-6 Output 6 L1-7 Output 7 L1-8 Output 8 L1-9 Output 9 L1-10 Output 10 L1-11 Output 11 L1-12 Output 12 L1-13 Output 13 L1-14 Output 14 L1-15 Output 15 Not used Not used Not used Not used 9 10 19 20 2 1 4 3 6 5 8 7 12 11 14 13 16 15 18 17 22 21 24 23 26 25 28 27 32 31 34 33 36 35 38 37 29 30 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y 1756-OA16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue L1-0 OUT-0 L1-1 OUT-1 L1-2 OUT-2 L1-3 OUT-3 L1-4 OUT-4 L1-5 OUT-5 L1-6 OUT-6 L1-7 OUT-7 L1-8 OUT-8 L1-9 OUT-9 L1-10 OUT-10 L1-11 OUT-11 L1-12 OUT-12 L1-13 OUT-13 L1-14 OUT-14 L1-15 OUT-15 1771-WN Swing Arm From 1771-OD16 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OD16 module output current limits versus 1756-OA16I limits are as follows: a) Current/Point b) Current/Module b) Surge Current/Point 1771-OD16 2A 8A 20A for 100ms 1756-OA16I w/ 1492-CONCAB005Y 1A 4A 20A for 43ms The 1771-OD16 has sixteen (16) 3A ,250V recifier fuses. The 1756-OA16I is NOT fused,as such sixteen (16) 2AG fuse clips are provided on the 1492-CM1771-LD010F conversion module. Max fuse rating is 1.5A based on 1756-OA16I. The 1771-OD16 is rated 74V to 138V AC and 105V to 138V DC. The 1756-OA16I is rated 74V to 265V AC. A1756 isolated output module with an equivalent DC voltage range to convert the1771 -OD16 is not available. Refer to your 1771-OD16 and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module rating are not exceeded. [Reference Doc: 41170-939 (Version 01)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 57 Wiring Diagrams - Digital Outputs 1771-ODD to 1756-OA16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD010F L1 L2 LOAD Not Used Not Used Not Used Not Used L1-0 Ouput 0 L1-1 Ouput 1 L1-2 Ouput 2 L1-3 Ouput 3 L1-4 Ouput 4 L1-5 Ouput 5 L1-6 Ouput 6 L1-7 Ouput 7 L1-8 Ouput 8 L1-9 Ouput 9 L1-10 Ouput 10 L1-11 Ouput 11 L1-12 Ouput 12 L1-13 Ouput 13 L1-14 Ouput 14 L1-15 Ouput 15 Not Used Not Used Not Used Not Used 9 10 19 20 2 1 4 3 6 5 8 7 12 11 14 13 16 15 18 17 22 21 24 23 26 25 28 27 32 31 34 33 36 35 38 37 29 30 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-OA16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L1-0 OUT-0 L1-1 OUT-1 L1-2 OUT-2 L1-3 OUT-3 L1-4 OUT-4 L1-5 OUT-5 L1-6 OUT-6 L1-7 OUT-7 L1-8 OUT-8 L1-9 OUT-9 L1-10 OUT-10 L1-11 OUT-11 L1-12 OUT-12 L1-13 OUT-13 L1-14 OUT-14 L1-15 OUT-15 1771-WN Swing Arm From 1771-ODD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-ODD module output current limits versus 1756-OA16I limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-ODD 2A 8A 20A for 100ms 1756-OA16I w/ 1492-CONCAB005Y 2A 5A 20A for 43ms The 1771-ODD has sixteen (16) 3A, 250V rectifier fuses. The 1756-OA16I is NOT fused, as such sixteen(16) 2AG fuses and clips are provided on the 1492-CM1771-LD010F conversion module. Max fuse rating is 1.5A based on 1756-OA16I. The 1771-ODD is rated 74V to 138V AC. The 1756-OA16I is rated 74V to 265V AC. Refer to your 1771-ODD and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 58 [Reference Doc: 41171-009 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-ODZ to 1756-OA16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD012 L1 L2 LOAD + - LOAD Out-0 N.O./N.C. +V0/1 Out-1 N.O./N.C. Out-2 N.O./N.C. +V2/3 Out-3 N.O./N.C. Out-4 N.O./N.C. +V4/5 Out-5 N.O./N.C. Out-6 N.O./N.C. +V6/7 Out-7 N.O./N.C. 1 2 3 4 5 6 7 8 9 10 11 12 1771-WD Swing Arm From 1771-ODZ JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1492-CONCAB005Y Orange Blue Cable 1492-C005005XP CABLE”A” White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green 1756-OA16I 2 4 1 3 6 8 5 7 10 12 9 11 14 16 13 15 L1-0 L1-0 L2-0 L2-1 L1-1 L1-1 L2-2 L2-3 L1-2 L1-2 L2-4 L2-5 L1-3 L1-3 L2-6 L2-7 Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 33 34 35 36 NOT USED NOT USED NOT USED NOT USED 18 20 17 19 22 24 21 23 26 28 25 27 30 32 29 31 L1-4 L1-4 L2-8 L2-9 L1-5 L1-5 L2-10 L2-11 L1-4 L1-6 L2-12 L2-13 Conversion Module 1492-CM1771-LD012 L1 L2 LOAD + - LOAD Out-0 N.O./N.C. +V0/1 Out-1 N.O./N.C. Out-2 N.O./N.C. +V2/3 Out-3 N.O./N.C. Out-4 N.O./N.C. +V4/5 Out-5 N.O./N.C. Out-6 N.O./N.C. +V6/7 Out-7 N.O./N.C. 1771-WD Swing Arm From 1771-ODZ 1 2 3 4 5 6 7 8 9 10 11 12 JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 CABLE”B” Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green L1-7 L1-7 L2-14 L2-15 Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OA16I RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion The 1771-ODZ module output resistive current limits versus 1756-OA16I limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-ODZ 2A 6A 20A for 100ms 1756-OA16I w/ 1492-C005005XP 2A 5A @ 60°C 20A for 43ms The 1771-ODZ module had a jumper selection of N.O. and N.C. outputs. The 1756-OA16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-ODZ jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-ODZ and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-016 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 59 Wiring Diagrams - Digital Outputs 1771-OG to 1756-OG16 WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 + DC Output 0 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Common + 5V DC SUPPLY - Output Device + - A 0 1 2 3 4 5 6 7 B 1771-WC Swing Arm From 1771-OG 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 Red/White Cable 1492-C005005XS CABLE”A” Green/Black/White Red/Black/White White/Black/Red Black/White/Red Orange/Green Blue/Red Orange/Red White/Red Black/Red 1756-OG16 10 1 2 3 4 5 6 7 8 9 20 11 12 13 14 15 16 17 18 19 + DC -0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 - DC -0 + DC -1 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 - DC -1 SH Conversion Module 1492-CM1771-LA003 + DC Output 8 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Common + 5V DC SUPPLY - Output Device + - 1771-WC Swing Arm From 1771-OG A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 Red/White Green/Black/White Red/Black/White White/Black/Red Black/White/Red Orange/Green Blue/Red Orange/Red White/Red Black/Red CABLE”B” SH Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OG16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. The input delay times for the 1771-OG module versus the 1756-OG16 module are as follows: a) Off-to-On Delay b) On-to-Off Delay 1771-OG 1ms (+/-10ms) 1ms (+/-10ms) 1756-OG16 w/ 1492-C005005XS 45ms max (plus selectable filter) 145ms max (plus selectable filter) The 1771-OG module is rated 5V DC TTL INPUT MODULE. The 1756-OG16 module is rated 5V DC TTL INPUT MODULE only. Refer to your 1771-OG and 1756-OG16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 60 [Reference Doc: 41171-028 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OGD to 1756-OG16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD006 + - - dc Output Device + + dc + dc + dc + dc Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 - dc A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OG16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green DC-0+ RTN OUT-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 DC-1+ RTN OUT-1 1771-WH, WHF, WHFB Swing Arm From 1171-OGD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OG16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OGD module output current limits versus 1756-OG16 limits are as follows: a) Current/Point b) Current/Module 1771-OGD 1mA 310mA 1756-OG16 w/ 1492-CONCAB005X 24mA 384mA The 1771-OGD has a single 10A, 250V rectifier fuse (1/4 x 1-1/4 inch). The 1756-OG16 is electronically fused per group. Refer to the 1756-OG16 Installation Manual for details on electronic fusing. The 1771-OGD is rated 10V to 60V DC. The 1756-OG16 is rated 10V to 31.2V DC. Refer to your 1771-OGD and 1756-OG16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-006 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 61 Wiring Diagrams - Digital Outputs 1771-OM to 1756-OA16 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD014 A 0 1 2 3 L1-0 OUTPUT 00 OUTPUT 01 OUTPUT 02 OUTPUT 03 L1 L2 + - LOAD 4 5 6 7 B OUTPUT 04 OUTPUT 05 OUTPUT 06 OUTPUT 07 L2-0 1771-WA Swing Arm From 1771-OM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Cable 1492-C005005XG White Red Cable “A” 1 2 3 4 10 Green Orange Blue White/Black A 0 1 2 3 L1 L2 LOAD INPUT 12 INPUT 13 INPUT 14 INPUT 15 L2-1 1771-WA Swing Arm From 1771-OM 4 5 6 7 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 OUT-0 OUT-1 OUT-2 OUT-3 L1-0 Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White 5 6 7 8 9 Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Cable “B” 11 12 13 14 20 Conversion Module 1492-CM1771-LD014 L1-1 INPUT 08 INPUT 09 INPUT 10 INPUT 11 1756-OA16 Black OUT-4 OUT-5 OUT-6 OUT-7 L2-0 OUT-8 OUT-9 OUT-10 OUT-11 L1-1 Black White Red Green 15 16 17 18 19 Orange Blue White/Black Red/Black Green/Black OUT-12 OUT-13 OUT-14 OUT-15 L2-1 Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OA16 RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. The 1771-OM module output current limits versus 1756-OA16 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OM 2A 6A 20A for 100ms 1756-OA16 w/ 1492-CONCAB005XG 0.5 @ 60°C 4A @ 60°C 5A for 43ms The 1771-OM module is rated 220V to 240V AC. The 1756-OA16 module is rated 74V to 265V AC only. Refer to your 1771-OM and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 62 [Reference Doc: 41171-022 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OMD to 1756-OA16 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD006 L1 L2 - LOAD + L1 L1 L1 L1 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 L2 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 E Cable 1492-CONCAB005X 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-OA16 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green L1-0+ L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1+ L2-1 1771-WH, WHF, WHFB Swing Arm From 1771-OMD Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OA16 RTB. Recommended cable lengths of0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OMD module output current limits versus 1756-OA16 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OMD 2A 8A 25A for 100ms 1756-OA16 w/ 1492-CONCAB005X 0.5A 4A 5A for 43ms The 1771-OMD has a single 10A, 250V rectifier fuse (1/4 x 1 1/4 inch). The 1756-OA16 has a mechanical 3.15A @250V AC slow blow fuse. Refer to the 1756-OA16 Installation Manual for details on electronic fusing. The 1771-OMD is rated 184V to 250V AC. The 1756-OA16 is rated 74V to 265V AC. If the load source voltage is greater than 30V DC, then use the 1756-OC8 with the 1492-CM1771-LD008F conversion module. Refer to your 1771-OMD and 1756-OA16 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-007 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 63 Wiring Diagrams - Digital Outputs 1771-ON to 1756-ON8 WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD014 L1 Output 00 Output 01 Output 02 Output 03 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 A 0 1 2 3 L1 L2 LOAD Output 04 Output 05 Output 06 Output 07 L2 Cable 1492-CONCAB005W 4 5 6 7 B Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green 1756-ON8 9 2 1 3 5 7 4 6 8 10 12 14 16 18 11 13 15 17 19 20 NOT USED L1-0 OUT-0 OUT-1 OUT-2 OUT-3 L1-0 L1-0 L1-0 L1-0 L1-1 L1-1 L1-1 L1-1 OUT-4 OUT-5 OUT-6 OUT-7 NOT USED L1-1 1771-WA Swing Arm From 1771-ON Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-ON8 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-ON module output current limits versus 1756-ON8 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-ON 1.5A 6A 4A for 10ms 1756-ON8 w/ 1492-CONCAB005W 2A 5A @ 60°C 20A for 43ms The 1771-ON has eight (8) 2A, 250V fuses - 1 per output. The 1756-ON8 is electronically fused per point. Refer to the 1756-ON8 Installation Manual for details on electronic fusing. Refer to your 1771-ON and 1756-ON8 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 64 [Reference Doc: 41171-021 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OND to 1756-ON8 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Cable 1492-CONCAB005S2 Conversion Module 1492-CM1771-LD006 L1 L1 L1 L2 Output Device L1 L1 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 L2 A B C D 00 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 E Black White Red 1756-ON8 2 4 6 8 10 9 1 3 5 7 11 13 15 17 Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black 19 Black/White 14 16 18 20 Red/White Green/White Blue/White Black/Red L1-0 L1-0 L1-0 L1-0 L1-0 NOT USED OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 NOT USED L1-1 L1-1 L1-1 L1-1 L1-1 White/Red Orange/Red Blue/Red 1756-ON8 Red/Green 2 4 6 8 10 9 1 3 5 7 11 13 15 17 1771-WH, WHF Swing Arm From 1771-OND 19 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to two 1756-ON8 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. 14 16 18 20 L1-0 L1-0 L1-0 L1-0 L1-0 NOT USED OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 NOT USED L1-1 L1-1 L1-1 L1-1 L1-1 The 1771-OND module output current limits versus (2)1756-ON8 limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OND 2A 8A 25A for 100ms 1756-ON8 w/ 1492-CONCAB005S2 2A 5A 20A for 43ms The L2 terminal (Terminal E) on the 1771-ON8 module was an optional connection, but it is required for the 1756-OA16. This connection must be added if it was not connected. The 1771-OND is rated 24V AC. The 1756-ON8 is rated 10V to 30V AC. Refer to your 1771-OND and 1756-ON8 Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-008 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 65 Wiring Diagrams - Digital Outputs 1771-OQ to 1756-OB16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LA004 LOAD + LOAD Not Used DC-1 OUTPUT-0 DC-1 OUTPUT 1 OUTPUT 2 DC-2 OUTPUT 3 DC-2 DC-3 OUTPUT-4 DC-3 OUTPUT 5 OUTPUT 6 DC-4 OUTPUT 7 DC-4 Not Used 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Cable 1492-C005005XT 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Orange/Red Cable “A” White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black Green/Black Red/Black White/Black Blue Orange Green Red White Conversion Module 1492-CM1771-LA004 LOAD + LOAD 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 17 20 19 21 22 23 24 26 25 28 27 29 30 31 32 Cable “B” 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 2 1 4 3 5 6 7 8 10 9 12 11 13 14 15 16 Black 1771-WF Swing Arm From 1771-OQ Not Used DC-1 OUTPUT-8 DC-1 OUTPUT 9 OUTPUT 10 DC-2 OUTPUT 11 DC-2 DC-3 OUTPUT-12 DC-3 OUTPUT 13 OUTPUT 14 DC-4 OUTPUT 15 DC-4 Not Used 1756-OB16I Orange/Red White/Red Black/Red Blue/White Green/White Red/White 33 34 35 36 Black/White Blue/Black Orange/Black DC-1 OUTPUT-0 DC-1 OUTPUT 1 OUTPUT 2 DC-2 OUTPUT 3 DC-2 DC-3 OUTPUT-4 DC-3 OUTPUT 5 OUTPUT 6 DC-4 OUTPUT 7 DC-4 DC-1 OUTPUT-8 DC-1 OUTPUT 9 OUTPUT 10 DC-2 OUTPUT 11 DC-2 DC-3 OUTPUT-12 DC-3 OUTPUT 13 OUTPUT 14 DC-4 OUTPUT 15 DC-4 NOT USED NOT USED NOT USED NOT USED Green/Black Red/Black White/Black Blue Orange Green Red White Black 1771-WF Swing Arm From 1771-OQ Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OB16I RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion The 1771-OQ module output resistive current limits versus 1756-OB16I limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OQ 2.25A 9A 4A for 10ms 1756-OB16I w/ 1492-C005005XT 2A 8A 4A for 10ms The 1771-OQ is rated 10V to 32V DC. The 1756-OB16I is rated 10V to 30V DC. Refer to your 1771-OQ and 1756-OB16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. 66 [Reference Doc: 41171-033 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OQ16 to 1756-OB16I WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD010F LOAD + - Not Used Not Used Not Used Not Used DC-0 Ouput 0 DC-1 Ouput 1 DC-2 Ouput 2 DC-3 Ouput 3 DC-4 Ouput 4 DC-5 Ouput 5 DC-6 Ouput 6 DC-7 Ouput 7 DC-8 Ouput 8 DC-9 Ouput 9 DC-10 Ouput 10 DC-11 Ouput 11 DC-12 Ouput 12 DC-13 Ouput 13 DC-14 Ouput 14 DC-15 Ouput 15 Not Used Not Used Not Used Not Used 9 10 19 20 2 1 4 3 6 5 8 7 12 11 14 13 16 15 18 17 22 21 24 23 26 25 28 27 32 31 34 33 36 35 38 37 29 30 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y 1756-OB16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue DC-0 OUT-0 DC-1 OUT-1 DC-2 OUT-2 DC-3 OUT-3 DC-4 OUT-4 DC-5 OUT-5 DC-6 OUT-6 DC-7 OUT-7 DC-8 OUT-8 DC-9 OUT-9 DC-10 OUT-10 DC-11 OUT-11 DC-12 OUT-12 DC-13 OUT-13 DC-14 OUT-14 DC-15 OUT-15 1771-WN Swing Arm From 1771-OQ16 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OB16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OQ16 module output current limits versus 1756-OB16I limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OQ16 2A 32A 4A for 10ms 1756-OB16I w/ 1492-CONCAB005Y 2A 8A 4A for 10ms The 1771-OQ16 has sixteen (16) 3A, 250V rectifier fuses. The 1756-OB16I is NOT fused, as such sixteen(16) 2AG fuses and clips are provided on the 1492-CM1771-LD010F conversion module. Max fuse rating is 1.5A based on 1756-OA16I. The 1771-OQ16 is rated 10V to 32V DC. The 1756-OB16I is rated 10V to 30V DC. Refer to your 1771-OQ16 and 1756-OB16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-010 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 67 Wiring Diagrams - Digital Outputs 1771-OR to 1756-OB16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. WARNING IMPORTANT Conversion Module 1492-CM1771-LD012 L2 L1 LOAD 0-IN 0-OUT 1-IN 1-OUT 2-IN 2-OUT 3-IN 3-OUT 4-IN 4-OUT 5-IN 5-OUT 1 2 3 4 5 6 7 8 9 10 11 12 1771-WD Swing Arm From 1771-OR JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1492-CONCAB005Y Orange Blue Cable 1492-C005005XR CABLE ”A” White/Black 1 3 5 Red/Black Green/Black Orange/Black Blue/Black 4 6 8 Black/White Red/White Green/White Blue/White 9 11 13 Black/Red White/Red Orange/Red Blue/Red 10 12 Red/Green Orange/Green L2 L1 LOAD 6-IN 6-OUT 7-IN 7-OUT 8-IN 8-OUT 9-IN 9-OUT 10-IN 10-OUT 11-IN 11-OUT 1 2 3 4 5 6 7 8 9 10 11 12 1771-WD Swing Arm From 1771-OR JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 L2-0 L1-0 L1-1 L1-2 L2-1 L2-2 L2-3 L1-3 L1-4 L1-5 L2-4 L2-5 Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue Conversion Module 1492-CM1771-LD012 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1756-OA16I 2 Orange 26 27 28 NOT USED NOT USED NOT USED 29 30 31 32 33 34 35 36 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED CABLE ”B” 14 Blue White/Black 15 17 19 Red/Black Green/Black Orange/Black Blue/Black 16 18 20 Black/White Red/White Green/White Blue/White 21 23 25 Black/Red White/Red Orange/Red Blue/Red 22 24 Red/Green Orange/Green L2-6 L1-6 L1-7 L1-8 L2-7 L2-8 L2-9 L1-9 L1-10 L1-11 L2-10 L2-11 Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OA16I RTB. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion The 1771-OR module output resistive current limits versus 1756-OA16I limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OR 2A 6A 15A for 100ms 1756-OA16I w/ 1492-C005005XR 2A 5A @ 60°C 20A for 43ms The 1771-OR module had a jumper selection of N.O. and N.C. outputs. The 1756-OA16I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OR jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-OR and 1756-OA16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-017 (Version 00)] 68 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OVN to 1756-OV16E WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD013 Output Device 1 11 10 20 2 3 4 5 6 7 8 9 12 13 14 15 16 17 18 19 L1 L1 L2 L2 21 31 30 40 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 Cable 1492-CONCAB005S3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1756-OV16E 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red L1-0 L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1 L2-1 MODULE A L2 L1 L1 L2 L2 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 1756-OV16E 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 10 9 1 2 3 4 5 6 7 8 11 12 13 14 15 16 17 18 20 19 Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue 1771-WN Swing Arm From 1771-OVN L1-0 L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1 L2-1 MODULE B L1 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to two 1756-OV16E RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OVN module output current limits versus 1756-OV16E limits are as follows: a) Current/Point b) Current/Module c) Surge Current/Point 1771-OVN 0.5A 8A (32 pts) 2A for 10ms 1756-OV16E w/ 1492-CONCAB005S3 1A 8A (16 pts) 2A for 10ms The 1771-OVN has 4 groups (allowing 4 separate power supplies). This module/cable combination ties all 4 groups from the 1771-OVN together. Field wiring modification must be made to accommodate this if mulitple supplies were used. If more than 1 supply was used, all but 1 of the power supplies must be removed. The 1771-OVN did not allow connections for L2, however the 1756-OV16E requires an L2 connection for proper operation. The 1771OVN did not use terminals 10, 20, 30, 40. These terminals have been reassigned for an L2 connection in this application. The installer must rewire L2 to one of these terminals. Refer to your 1771-OVN and 1756-OV16E Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. This configuration uses two (2) 1756-OV16E output modules to replace a single 1771-OVN output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. [Reference Doc: 41171-018 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 69 Wiring Diagrams - Digital Outputs 1771-OW to 1756-OX8I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD012 1 2 4 JMP0 3 N.C. N.O. 2 1 4 JMP1 3 N.C. N.O. L1 L2 LOAD + - LOAD Out-0 N.O./N.C. +V0/1 Out-1 N.O./N.C. Out-2 N.O./N.C. +V2/3 Out-3 N.O./N.C. Out-4 N.O./N.C. +V4/5 Out-5 N.O./N.C. Out-6 N.O./N.C. +V6/7 Out-7 N.O./N.C. 2 1 4 JMP2 3 N.C. 1 2 3 4 5 6 N.O. 2 1 4 JMP3 3 N.C. N.O. 7 8 9 10 11 12 2 1 4 JMP4 3 N.C. N.O. 2 1 4 JMP5 3 N.C. N.O. 2 1 4 JMP6 3 N.C. N.O. 2 1 4 JMP7 3 N.C. N.O. 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-OX8I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L1-0 OUT-0 N.C. L1-0 OUT-0 N.O. L1-1 OUT-1 N.C. L1-1 OUT-1 N.O. L1-2 OUT-2 N.C. L1-2 OUT-2 N.O. L1-3 OUT-3 N.C. L1-3 OUT-3 N.O. L1-4 OUT-4 N.C. L1-4 OUT-4 N.O. L1-5 OUT-5 N.C. L1-5 OUT-5 N.O. L1-6 OUT-6 N.C. L1-6 OUT-6 N.O. L1-7 OUT-7 N.C. L1-7 OUT-7 N.O. 1771-WD Swing Arm From 1771-OW Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M), 010=1.0M). See table 2 for other lengths. The 1771-OW module output resistive current limits versus 1756-OX8I limits are as follows: (NOTE: For switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OW 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 0.2A @ 138V AC 2A @ 240V AC 1A @ 30V DC 2A @ 30V DC 0.25A @ 125V DC 0.25A @ 125V DC The 1771-OW module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OW jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-OW and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41170-941 (Version 01)] 70 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OW16 to 1756-OW16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LD011 L1 LOAD L2 + - LOAD Output 10 (NC) Output 11 (NC) Output 12 (NC) Output 13 (NC) Common 00 Output 00 Common 01 Output 01 Common 02 Output 02 Common 03 Output 03 Common 04 Output 04 Common 05 Output 05 Common 06 Output 06 Common 07 Output 07 Common 10 Output 10 (NO) Common 11 Output 11(NO) Common 12 Output 12 (NO) Common 13 Output 13 (NO) Common 14 Output 14 (NO) Common 15 Output 15 (NO) Common 16 Output 16 (NO) Common 17 Output 17 (NO) Output 14 (NC) Output 15 (NC) Output 16 (NC) Output 17 (NC) 17 20 23 26 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 19 18 22 21 25 24 28 27 31 30 34 33 37 36 40 39 29 32 35 38 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-OW16I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L1-0 OUT-0 N.O. L1-1 OUT-1 N.O. L1-2 OUT-2 N.O. L1-3 OUT-3 N.O. L1-4 OUT-4 N.O. L1-5 OUT-5 N.O. L1-6 OUT-6 N.O. L1-7 OUT-7 N.O. L1-8 OUT-8 N.O. L1-9 OUT-9 N.O. L1-10 OUT-10 N.O. L1-11 OUT-11 N.O. L1-12 OUT-12 N.O. L1-13 OUT-13 N.O. L1-14 OUT-14 N.O. L1-15 OUT-15 N.O. 1771-WN Swing Arm From 1771-OW16 Conversion Module Installation and Application Considerations The 1771-OW16 module output resistive current limits versus 1756-OW16I limits are as follows: 1771-OW16 1756-OW16I w/ 1492-CONCAB005Y a) Current/Point 2A @ 250V AC 2A @ 240V AC 2A @ 30V DC 2A @ 30V DC 0.3A @ 150V DC 0.25A @ 125V AC The 1492-CONCAB005Y is limited to 3A per pin. The 1771-OW16 has N.O. and N.C. relay contact outputs. The 1756-OW16I has N.O. relay contact outputs only. The conversion module does not convert the N.C. to N.O. contacts. If the 1771-OW16 N.C. outputs were being used, the installer must rewire the 1771-WN swing arm and move the N.C. wires to the N.O. output terminals. In addition, the control Logix programming will need to be changed to simulate a N.C. relay with this output. Refer to your 1771-OW16 and 1756-OW16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. Reference Doc: 41170-940 (Version 01)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 71 Wiring Diagrams - Digital Outputs 1771-OWNA to 1756-OW16I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. L1 L2 Output Device L1 L1 L2 L2 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 1 11 10 20 2 3 4 5 6 7 8 9 12 13 14 15 16 17 18 19 Cable 1492-CONCAB005S4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1756-OW16I 2 Black White Red 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 4 6 Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red 32 34 L1 L1 L2 L2 Output 00 Output 01 Output 02 Output 03 Output 04 Output 05 Output 06 Output 07 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Output 17 21 31 30 40 22 23 24 25 26 27 28 29 32 33 34 35 36 37 38 39 L1-0 L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1 L1-1 L1-1 L1-1 MODULE A Conversion Module 1492-CM1771-LD013 1756-OW16I 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 2 Red/Green Orange/Green 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 4 6 Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue White/Red/Blue 1771-WN Swing Arm From 1771-OWNA 32 34 L1-0 L2-0 OUT-0 OUT-1 OUT-2 OUT-3 OUT-4 OUT-5 OUT-6 OUT-7 OUT-8 OUT-9 OUT-10 OUT-11 OUT-12 OUT-13 OUT-14 OUT-15 L1-1 L1-1 L1-1 L1-1 MODULE B IMPORTANT Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to two 1756-OW16I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. The 1771-OWNA module output current limits versus 1756-OW16I limits are as follows: a) Current/Point b) Current/Module 1771-OWNA 1A 12A (32 pts) 1756-OW16I w/ 1492-CONCAB005S4 0.5A 2A (16 pts) The 1771-OWNA has 4 groups (allowing 4 separate power supplies). This module/cable combination ties all 4 groups from the 1771 -OWNA together. Field wiring modification must be made to accommodate this if mulitple supplies were used. If more than 1 supply wa s used, all but 1 of the power supplies must be removed. The 1771-OWNA did not allow connections for L2, however the 1756-OW16I requires an L2 connection for proper operation. The 1771-OWNA did not use terminals 10, 20, 30, 40. These terminals have been reassigned for an L2 connection in this application. The installer must rewire L2 to one of these terminals. Refer to your 1771-OWNA and 1756-OW16I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. This configuration uses two (2) 1756-OW16I output modules to replace a single 1771-OWNA output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. 1756-OW16I output modules has all inputs jumpered together pins 2 through 34 even. [Reference Doc: 41171-019 (Version 00)] 72 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OY to 1756-OX8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation. In addition, refer to the current draw requirements of the existing loads for this configuration to ensure they are within the current ratings of the 1756 output module. IMPORTANT Conversion Module 1492-CM1771-LD012 L1 L2 LOAD + - LOAD Out-0 N.O./N.C. +V0/1 Out-1 N.O./N.C. Out-2 N.O./N.C. +V2/3 Out-3 N.O./N.C. Out-4 N.O./N.C. +V4/5 Out-5 N.O./N.C. Out-6 N.O./N.C. +V6/7 Out-7 N.O./N.C. 1771-WD Swing Arm From 1771-OY 1 2 3 4 5 6 7 8 9 10 11 12 JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-OX8I c 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L1-0 OUT-0 N.C. L1-0 OUT-0 N.O. L1-1 OUT-1 N.C. L1-1 OUT-1 N.O. L1-2 OUT-2 N.C. L1-2 OUT-2 N.O. L1-3 OUT-3 N.C. L1-3 OUT-3 N.O. L1-4 OUT-4 N.C. L1-4 OUT-4 N.O. L1-5 OUT-5 N.C. L1-5 OUT-5 N.O. L1-6 OUT-6 N.C. L1-6 OUT-6 N.O. L1-7 OUT-7 N.C. L1-7 OUT-7 N.O. CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d The 1771-OY module output resistive current limits versus 1756-OX8I limits are as follows: (NOTE: for switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OY 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 100mA @ 138V AC 2A @ 240V AC 100mA @ 125V DC 2A @ 30V DC 0.25A @ 125V DC The 1771-OY module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. relay outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OY jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O.. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-OY and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. e f Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-011 (00) 73 Wiring Diagrams - Digital Outputs 1771-OYL to 1756-OX8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation. In addition, refer to the current draw requirements of the existing loads for this configuration to ensure they are within the current ratings of the 1756 output module. IMPORTANT Conversion Module 1492-CM1771-LD012 L1 L2 LOAD + - LOAD Out-0 N.O./N.C. +V0/1 Out-1 N.O./N.C. Out-2 N.O./N.C. +V2/3 Out-3 N.O./N.C. Out-4 N.O./N.C. +V4/5 Out-5 N.O./N.C. Out-6 N.O./N.C. +V6/7 Out-7 N.O./N.C. 1771-WD Swing Arm From 1771-OYL 1 2 3 4 5 6 7 8 9 10 11 12 JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y 1756-OX8I c Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L1-0 OUT-0 N.C. L1-0 OUT-0 N.O. L1-1 OUT-1 N.C. L1-1 OUT-1 N.O. L1-2 OUT-2 N.C. L1-2 OUT-2 N.O. L1-3 OUT-3 N.C. L1-3 OUT-3 N.O. L1-4 OUT-4 N.C. L1-4 OUT-4 N.O. L1-5 OUT-5 N.C. L1-5 OUT-5 N.O. L1-6 OUT-6 N.C. L1-6 OUT-6 N.O. L1-7 OUT-7 N.C. L1-7 OUT-7 N.O. CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d The 1771-OYL module output resistive current limits versus 1756-OX8I limits are as follows: (NOTE: for switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OYL 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 100mA @ 24V AC 2A @ 240V AC 100mA @ 24V DC 2A @ 30V DC 0.25A @ 125V DC The 1771-OYL module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. relay outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OYL jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O.. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-OYL and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. e f 41171-012 (00) 74 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Digital Outputs 1771-OZ to 1756-OX8I WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD012 L1 L2 LOAD + - LOAD Out-0 N.O./N.C. +V0/1 Out-1 N.O./N.C. Out-2 N.O./N.C. +V2/3 Out-3 N.O./N.C. Out-4 N.O./N.C. +V4/5 Out-5 N.O./N.C. Out-6 N.O./N.C. +V6/7 Out-7 N.O./N.C. 1 2 3 4 5 6 7 8 9 10 11 12 JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-OX8I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L1-0 OUT-0 N.C. L1-0 OUT-0 N.O. L1-1 OUT-1 N.C. L1-1 OUT-1 N.O. L1-2 OUT-2 N.C. L1-2 OUT-2 N.O. L1-3 OUT-3 N.C. L1-3 OUT-3 N.O. L1-4 OUT-4 N.C. L1-4 OUT-4 N.O. L1-5 OUT-5 N.C. L1-5 OUT-5 N.O. L1-6 OUT-6 N.C. L1-6 OUT-6 N.O. L1-7 OUT-7 N.C. L1-7 OUT-7 N.O. 1771-WD Swing Arm From 1771-OZ Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M), 010=1.0M). See table 2 for other lengths. The 1771-OZ module output resistive current limits versus 1756-OX8I limits are as follows: (NOTE: For switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OZ 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 100mA @ 138V AC 2A @ 240V AC 100mA @ 138V DC 2A @ 30V DC 0.25A @ 125V DC The 1771-OZ module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OZ jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-OZ and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-013 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 75 Wiring Diagrams - Digital Outputs 1771-OZL to 1756-OX8I WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LD012 L1 L2 LOAD + - LOAD Out-0 N.O./N.C. +V0/1 Out-1 N.O./N.C. Out-2 N.O./N.C. +V2/3 Out-3 N.O./N.C. Out-4 N.O./N.C. +V4/5 Out-5 N.O./N.C. Out-6 N.O./N.C. +V6/7 Out-7 N.O./N.C. JMP0 3 N.C. N.O. 2 1 JMP1 3 4 N.C. N.O. 2 1 JMP2 3 4 N.C. N.O. 2 1 JMP3 3 4 N.C. N.O. 2 1 JMP4 3 4 N.C. N.O. 2 1 JMP5 3 4 N.C. N.O. 2 1 JMP6 3 4 N.C. N.O. 2 1 JMP7 3 4 N.C. N.O. 2 1 4 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Cable 1492-CONCAB005Y Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Red/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green Black/White/Red White/Black/Red Red/Black/White Green/Black/White Orange/Black/White Blue/Black/White Black/Red/Green White/Red/Green Red/Black/Green Green/Black/Orange Orange/Black/Green Blue/White/Orange Black/White/Orange White/Red/Orange Orange/White/Blue 1756-OX8I 2 1 4 3 6 5 8 7 10 9 12 11 14 13 16 15 18 17 20 19 22 21 24 23 26 25 28 27 30 29 32 31 L1-0 OUT-0 N.C. L1-0 OUT-0 N.O. L1-1 OUT-1 N.C. L1-1 OUT-1 N.O. L1-2 OUT-2 N.C. L1-2 OUT-2 N.O. L1-3 OUT-3 N.C. L1-3 OUT-3 N.O. L1-4 OUT-4 N.C. L1-4 OUT-4 N.O. L1-5 OUT-5 N.C. L1-5 OUT-5 N.O. L1-6 OUT-6 N.C. L1-6 OUT-6 N.O. L1-7 OUT-7 N.C. L1-7 OUT-7 N.O. 1771-WD Swing Arm From 1771-OZL Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-OX8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M), 010=1.0M). See table 2 for other lengths. The 1771-OZL module output resistive current limits versus 1756-OX8I limits are as follows: (NOTE: For switching and inductive current ratings, refer to the modules Installation Instructions) 1771-OZL 1756-OX8I w/ 1492-CONCAB005Y a) Current/Point 100mA @ 138V AC 2A @ 240V AC 100mA @ 138V DC 2A @ 30V DC 0.25A @ 125V DC The 1771-OZL module had a jumper selection of N.O. and N.C. outputs. The 1756-OX8I has both N.O. and N.C. outputs, but selection is by wiring termination on the 1756 swing arm. The 1492-CM1771-LD012 conversion module replaces the functionality of the 1771-OZL jumpers with eight jumpers (JMP0 through JMP7). In the default position, the output will be N.O. If a N.C. output is required, change the jumper from pins 1-2 to pins 3-4. Refer to your 1771-OZL and 1756-OX8I Installation Manual wiring schematics and diagrams for more details. Ensure 1756 output module ratings are not exceeded. [Reference Doc: 41171-014 (Version 00)] 76 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-IFE to 1756-IF16 Differential Current WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation. 1492-CM1771-LA002 1756-IF16 1492-CONACAB005D + Power Supply - 4-Wire Transmitter + Transmitter - Channel 1+ Channel 1Channel 2+ Channel 2Channel 3+ Channel 3Channel 4+ Channel 4Not Used Not Used Not Used Module Common Module Common Channel 5+ Channel 5Channel 6+ Channel 6Channel 7+ Channel 7Channel 8+ Channel 8- 1 1 2 3 4 6 7 8 9 5 10 15 20 21 11 12 13 14 16 17 18 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Orange/Black Blue/Black Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green 2 4 6 8 12 14 16 18 10 1 5 11 15 20 22 24 26 30 32 34 36 19 23 29 33 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 RTN iRTN-0 iRTN-2 iRTN-4 iRTN-6 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 iRTN-8 iRTN-10 iRTN-12 iRTN-14 SH 1 1771-WG Swing Arm CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA002 module. The pre-wired cable used between the 1492-CM1771-LA002 module and the 1756-IF16 [1492-CONACAB005D] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. 2 This design assumes that all inputs on the1771-IFE were connected to current transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005D] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details. 3 The 1771-IFE analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16. 4 Refer to your 1771-IFE and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41170-946 (0) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 77 Wiring Diagrams - Analog Inputs and Outputs 1771-IFE to 1756-IF16 Differential Voltage IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1492-CM1771-LA002 4-Wire Transmitter + + Power Supply Transmitter - Channel 1+ Channel 1Channel 2+ Channel 2Channel 3+ Channel 3Channel 4+ Channel 4Not Used Not Used Not Used Module Common Module Common Channel 5+ Channel 5Channel 6+ Channel 6Channel 7+ Channel 7Channel 8+ Channel 8- 1 1492-CONACAB005C 1 2 3 4 6 7 8 9 5 10 15 20 21 1 2 3 4 5 6 7 8 9 10 11 12 13 Black 11 12 13 14 16 17 18 19 14 15 16 17 18 19 20 21 22 23 24 25 Green/White White Red Green Orange Blue White/Black Red/Black 2 4 6 8 12 14 16 18 10 Orange/Black 1756-IF16 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 RTN Blue/Black Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green 20 22 24 26 30 32 34 36 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 SH 1 1771-WG Swing Arm CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA002 module. The pre-wired cable used between the 1492-CM1771-LA002 module and the 1756-IF16 [1492-CONACAB005C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. 2 This design assumes that all inputs on the1771-IFE were connected to voltage transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005C] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details. 3 The 1771-IFE analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16. 4 Refer to your 1771-IFE and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41170-947 (1) 78 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-IFE to 1756-IF16 Single End Current WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1492-CM1771-LA001 1756-IF16 1492-CONACAB005B 2-Wire Transmitter + Power Supply - Transmitter Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Module Common Module Common Module Common Module Common Module Common 1 2 3 4 6 7 8 9 5 10 15 20 21 1 2 3 4 5 6 7 8 9 10 11 12 13 Black Black/White 28 Channel 9 Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16 11 12 13 14 16 17 18 19 14 15 16 17 18 19 20 21 22 23 24 25 Green/White 20 22 24 26 30 32 34 36 1 White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 RTN Blue/Black Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green SH 1 1771-WG Swing Arm 2 4 6 8 12 14 16 18 10 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 RTN IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 iRTN-0 iRTN-1 iRTN-2 iRTN-3 RTN iRTN-4 iRTN-5 iRTN-6 iRTN-7 iRTN-8 iRTN-9 iRTN-10 iRTN-11 RTN iRTN-12 iRTN-13 iRTN-14 iRTN-15 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA001 module. The pre-wired cable used between the 1492-CM1771-LA001 module and the 1756-IF16 [1492-CONACAB005B] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. 2 This design assumes that all inputs on the1771-IFE were connected to current transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005B] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details. 3 The 1771-IFE analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16. 41170-944 (1) 4 Refer to your 1771-IFE and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 79 Wiring Diagrams - Analog Inputs and Outputs 1771-IFE to 1756-IF16 Single End Voltage WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1492-CM1771-LA001 1492-CONACAB005A 3-Wire Transmitter Transmitter + Power Supply Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Module Common Module Common Module Common Module Common Module Common Channel 9 Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16 1 1 2 3 4 6 7 8 9 5 10 15 20 21 11 12 13 14 16 17 18 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green 2 4 6 8 12 14 16 18 10 9 27 28 20 22 24 26 30 32 34 36 1756-IF16 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 RTN RTN RTN RTN IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 SH 1 1771-WG Swing Arm CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA001 module. The pre-wired cable used between the 1492-CM1771-LA001 module and the 1756-IF16 [1492-CONACAB005A] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. 2 This design assumes that all inputs on the1771-IFE were connected to voltage transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005A] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details. 3 The 1771-IFE analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16. 4 Refer to your 1771-IFE and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41170-945 (1) 80 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-IFF to 1756-IF16 Differential Current WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA002 + Power Supply - 4-Wire Transmitter + Transmitter - Channel 1+ Channel 1Channel 2+ Channel 2Channel 3+ Channel 3Channel 4+ Channel 4Not Used Not Used Not Used Module Common Module Common Channel 5+ Channel 5Channel 6+ Channel 6Channel 7+ Channel 7Channel 8+ Channel 8- 1 2 3 4 6 7 8 9 5 10 15 20 21 11 12 13 14 16 17 18 19 d Cable 1492-CONACAB005D 1 2 3 4 5 6 7 8 9 10 11 12 13 Black 14 15 16 17 18 19 20 21 22 23 24 25 Green/White 1756-IF16 c White Red Green Orange Blue White/Black Red/Black Orange/Black Blue/Black Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green 2 4 6 8 12 14 16 18 10 1 5 11 15 20 22 24 26 30 32 34 36 19 23 29 33 IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 RTN iRTN-0 iRTN-2 iRTN-4 iRTN-6 IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 iRTN-8 iRTN-10 iRTN-12 iRTN-14 SH d 1771-WG Swing Arm From 1771-IFF CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c This Bul. 1492 cable consists of a cable wired to one 1756-IF16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA002 module. The pre-wired cable used between the 1492-CM1771-LA002 module and the 1756-IF16 [1492-CONACAB005D] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e This design assumes that all inputs on the1771-IFF were connected to current transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005D] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details. f The 1771-IFF analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16. g Refer to your 1771-IFF and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-025 (00) 81 Wiring Diagrams - Analog Inputs and Outputs 1771-IFF to 1756-IF16 Differential Voltage There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LA002 + Power Supply 4-Wire Transmitter + Transmitter - - Channel 1+ Channel 1Channel 2+ Channel 2Channel 3+ Channel 3Channel 4+ Channel 4Not Used Not Used Not Used Module Common Module Common Channel 5+ Channel 5Channel 6+ Channel 6Channel 7+ Channel 7Channel 8+ Channel 8- d Cable 1492-CONACAB005C 1 2 3 4 6 7 8 9 5 10 15 20 21 1 2 3 4 5 6 7 8 9 10 11 12 13 Black 11 12 13 14 16 17 18 19 14 15 16 17 18 19 20 21 22 23 24 25 Green/White 1756-IF16 2 4 6 8 12 14 16 18 10 White Red Green Orange Blue White/Black Red/Black Orange/Black IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 RTN Blue/Black 20 22 24 26 30 32 34 36 Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 SH d 1771-WG Swing Arm From 1771-IFF CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c This Bul. 1492 cable consists of a cable wired to one 1756-IF16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA002 module. The pre-wired cable used between the 1492-CM1771-LA002 module and the 1756-IF16 [1492-CONACAB005C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e This design assumes that all inputs on the1771-IFF were connected to voltage transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005C] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details. f The 1771-IFF analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16. g Refer to your 1771-IFF and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41171-026 (00) 82 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-IFF to 1756-IF16 Single End Current IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA001 2-Wire Transmitter + Power Supply - Transmitter Cable 1492-CONACAB005B c 1756-IF16 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Module Common Module Common Module Common Module Common Module Common 1 2 3 4 6 7 8 9 5 10 15 20 21 1 2 3 4 5 6 7 8 9 10 11 12 13 Black Black/White 28 Channel 9 Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16 11 12 13 14 16 17 18 19 14 15 16 17 18 19 20 21 22 23 24 25 Green/White 20 22 24 26 30 32 34 36 d White Red Green Orange Blue White/Black Red/Black Green/Black 2 4 6 8 12 14 16 18 10 Orange/Black IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 RTN Blue/Black Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green SH d 1771-WG Swing Arm From 1771-IFF 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 RTN IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 iRTN-0 iRTN-1 iRTN-2 iRTN-3 RTN iRTN-4 iRTN-5 iRTN-6 iRTN-7 iRTN-8 iRTN-9 iRTN-10 iRTN-11 RTN iRTN-12 iRTN-13 iRTN-14 iRTN-15 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c This Bul. 1492 cable consists of a cable wired to one 1756-IF16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA001 module. The pre-wired cable used between the 1492-CM1771-LA001 module and the 1756-IF16 [1492-CONACAB005B] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e This design assumes that all inputs on the1771-IFF were connected to current transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005B] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details. The 1771-IFF analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16. f g Refer to your 1771-IFF and 1756-IF16 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-023 (00) 83 Wiring Diagrams - Analog Inputs and Outputs 1771-IFF to 1756-IF16 Single End Voltage There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LA001 Cable 1492-CONACAB005A c 3-Wire Transmitter Transmitter + Power Supply Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Module Common Module Common Module Common Module Common Module Common Channel 9 Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16 d 1 2 3 4 6 7 8 9 5 10 15 20 21 11 12 13 14 16 17 18 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1756-IF16 2 4 6 8 12 14 16 18 10 9 27 28 Black White Red Green Orange Blue White/Black Red/Black Green/Black Orange/Black Blue/Black Black/White 20 22 24 26 30 32 34 36 Green/White Blue/White Black/Red White/Red Orange/Red Blue/Red Red/Green Orange/Green IN-0 IN-1 IN-2 IN-3 IN-4 IN-5 IN-6 IN-7 RTN RTN RTN RTN IN-8 IN-9 IN-10 IN-11 IN-12 IN-13 IN-14 IN-15 SH d 1771-WG Swing Arm From 1771-IFF CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c This Bul. 1492 cable consists of a cable wired to one 1756-IF16 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA001 module. The pre-wired cable used between the 1492-CM1771-LA001 module and the 1756-IF16 [1492-CONACAB005A] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e This design assumes that all inputs on the1771-IFF were connected to voltage transmitters. If there was a mix of current and voltage transmitters, then modification of the pre-wired cable [1492-CONACAB005A] will need to occur at the 1756-IF16 terminal block. Refer to the 1756-IF16 Installation Manual for modification details. f The 1771-IFF analog input ranges were configured via software, as is the input range for the 1756-IF16. Please ensure the correct input range is configured in the 1756-IF16. g Refer to your 1771-IFF and 1756-IF16 Installation and User Manuals for additional information concerning comparisons 41171-024 (00) of module wiring, features and configuration details. 84 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-IL to 1756-IF8I Current There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LA004 Cable 1756-IF8I 1492-CONACAB005K8 4-Wire Transmitter + Power Supply Transmitter - + - 2-Wire Transmitter + - Channel0 Channel0 Channel1 Channel1 Channel2 Channel2 Channel3 Channel3 Channel4 Channel4 Channel5 Channel5 Channel6 Channel6 Channel7 Channel7 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Orange/Red White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black 4 6 3 5 12 14 11 13 Orange/Black Iin_CH0 RTN_CH0 Iin_CH1 RTN_CH1 Iin_CH2 RTN_CH2 Iin_CH3 RTN_CH3 Green/Black Red/Black White/Black Blue Orange Red / Black White / Black Blue Orange SH 20 22 19 21 28 30 27 29 1 2 7 8 9 10 15 16 17 18 Iin_CH4 RTN_CH4 Iin_CH5 RTN_CH5 Iin_CH6 RTN_CH6 Iin_CH7 RTN_CH7 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 1771-WF Swing Arm From 1771-IL CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS This Bul. 1492 cable consists of a cable wired to one 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF8I [1492-CONACAB005K8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. The 1771-IL input configuration was software configured, as is the 1756-IF8I. Please ensure the correct configuration in the 1756-IF8I. Refer to your 1771-IL and 1756-IF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 85 Wiring Diagrams - Analog Inputs and Outputs 1771-IL to 1756-IF8I Voltage There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LA004 Cable 1756-IF8I 1492-CONACAB005L8 4-Wire Transmitter + Power Supply Transmitter - + - Vout_CH0 RTN_CH0 Vout_CH1 RTN_CH1 Vout_CH2 RTN_CH2 Vout_CH3 RTN_CH3 Vout_CH4 RTN_CH4 Vout_CH5 RTN_CH5 Vout_CH6 RTN_CH6 Vout_CH7 RTN_CH7 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 17 16 15 14 13 12 11 10 Orange/Red 9 8 7 6 5 4 3 2 1 Green/Black 2 6 1 5 10 14 9 13 White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black 18 22 17 21 26 30 25 29 Red/Black White/Black Blue Orange Red / Black White / Black Blue Orange 3 SH 3 Vout_CH0 RTN_CH0 Vout_CH1 RTN_CH1 Vout_CH2 RTN_CH2 Vout_CH3 RTN_CH3 Vout_CH4 RTN_CH4 Vout_CH5 RTN_CH5 Vout_CH6 RTN_CH6 Vout_CH7 RTN_CH7 3 4 7 8 11 12 15 16 19 20 1771-WF Swing Arm From 1771-IL This Bul. 1492 cable consists of a cable wired to one 1756-IF8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF8I [1492-CONACAB005L8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. The 1771-IL input configuration was software configured, as is the 1756-IF8I. Please ensure the correct configuration in the 1756-IF8I. Refer to your 1771-IL and 1756-IF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 86 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 27 28 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - Analog Inputs and Outputs 1771-IL to 1756-IF6I — 6-ch Current There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LA004 Cable 1492-CONACAB005K 4-Wire Transmitter + Power Supply Transmitter - + 2-Wire Transmitter - + - Channel0 Channel0 Channel1 Channel1 Channel2 Channel2 Channel3 Channel3 Channel4 Channel4 Channel5 Channel5 Channel6 Channel6 Channel7 Channel7 d 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 17 16 15 14 13 12 11 10 Orange/Red 9 8 7 6 5 4 3 2 1 Green/Black 1756-IF6I c 3 5 4 6 9 11 10 12 White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black 1 2 7 8 Red/Black White/Black Blue IN-0/I RET-0 IN-1/I RET-1 IN-2/I RET-2 IN-3/I RET-3 IN-0/V IN-1/V IN-2/V IN-3/V Orange Green Red 17 19 18 20 15 16 White Black IN-4/I RET-4 IN-5/I RET-5 IN-4/V IN-5/V SH d 1771-WF Swing Arm From 1771-IL CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c This Bul. 1492 cable consists of a cable wired to one 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF6I [1492-CONACAB005K] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e The 1771-IL input configuration was software configured, as is the 1756-IF6I. Please ensure the correct configuration in the 1756-IF6I. f Refer to your 1771-IL and 1756-IF6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-030 (00) 87 Wiring Diagrams - Analog Inputs and Outputs 1771-IL to 1756-IF6I — 6-ch Voltage IMPORTANTARNING There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA004 2-Wire Transmitter + Transmitter - + Power Supply - Channel0 Channel0 Channel1 Channel1 Channel2 Channel2 Channel3 Channel3 Channel4 Channel4 Channel5 Channel5 Channel6 Channel6 Channel7 Channel7 d 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Cable 1492-CONACAB005L c 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Orange/Red White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black Green/Black Red/Black White/Black Blue Orange Green Red 1756-IF6I 1 5 2 4 7 11 8 12 9 10 15 19 16 20 3 4 13 14 17 18 White Black IN-0 RET-0 IN-1 RET-1 IN-2 RET-2 IN-3 RET-3 NO CONNECT NO CONNECT IN-4 RET-4 IN-5 RET-5 NO CONNECT NO CONNECT NO CONNECT NO CONNECT NO CONNECT NO CONNECT SH d 1771-WF Swing Arm From 1771-IL c This Bul. 1492 cable consists of a cable wired to one 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF6I [1492-CONACAB005L] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e The 1771-IL input configuration was software configured, as is the 1756-IF6I. Please ensure the correct configuration in the 1756-IF6I. f Refer to your 1771-IL and 1756-IF6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41171-029 (00) 88 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-IL to 1756-IF6I — (2 x 4-ch) Current IMPORTANT Conversion Module 1492-CM1771-LA004 Cable 1492-CONACAB005T1 1756-IF6I 4-Wire Transmitter + Power Supply Transmitter + - - 2-Wire Transmitter + Channel0 Channel0 Channel1 Channel1 Channel2 Channel2 Channel3 Channel3 Channel4 Channel4 Channel5 Channel5 Channel6 Channel6 Channel7 Channel7 - 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 3 5 4 6 9 11 10 12 Orange/Red White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black 1 2 7 8 Green/Black Red/Black White/Black Blue IN-0/I RET-0 IN-1/I RET-1 IN-2/I RET-2 IN-3/I RET-3 IN-0/V IN-1/V IN-2/V IN-3/V Orange Green Red 17 19 18 20 15 16 White Black IN-4/I RET-4 IN-5/I RET-5 IN-4/V IN-5/V SH 1771-WF Swing Arm From 1771-IL 1756-IF6I 3 5 4 6 9 11 10 12 1 2 7 8 17 19 18 20 15 16 IN-0/I RET-0 IN-1/I RET-1 IN-2/I RET-2 IN-3/I RET-3 IN-0/V IN-1/V IN-2/V IN-3/V IN-4/I RET-4 IN-5/I RET-5 IN-4/V IN-5/V Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to two 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF6I [1492-CONACAB005T1] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. The 1771-IL input configuration was software configured, as is the 1756-IF6I. Please ensure the correct configuration in the 1756-IF6I. Refer to your 1771-IL and 1756-IF6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. This configuration uses two (2) 1756-IF6I output modules to replace a single 1771-IL output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. [Reference Doc: 41171-032 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 89 Wiring Diagrams - Analog Inputs and Outputs 1771-IL to 1756-IF6I — (2 x 4-ch) Voltage There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module 1492-CM1771-LA004 + Power Supply 4-Wire Transmitter + Transmitter - - 2-Wire Transmitter + Channel0 Channel0 Channel1 Channel1 Channel2 Channel2 Channel3 Channel3 - Channel4 Channel4 Channel5 Channel5 Channel6 Channel6 Channel7 Channel7 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 d Cable 1492-CONACAB005T2c 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Orange/Red White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black Green/Black Red/Black White/Black Blue Orange Green Red 1756-IF6I 1 5 2 6 7 11 8 12 9 10 15 19 16 20 3 4 13 14 17 18 White Black SH 1756-IF6I d 1771-WF Swing Arm From 1771-IL IN-0 RET-0 IN-1 RET-1 IN-2 RET-2 IN-3 RET-3 NO CONNECT NO CONNECT IN-4 RET-4 IN-5 RET-5 NO CONNECT NO CONNECT NO CONNECT NO CONNECT NO CONNECT NO CONNECT 1 5 2 4 7 11 8 12 9 10 15 19 16 20 3 4 13 14 17 18 IN-0 RET-0 IN-1 RET-1 IN-2 RET-2 IN-3 RET-3 NO CONNECT NO CONNECT IN-4 RET-4 IN-5 RET-5 NO CONNECT NO CONNECT NO CONNECT NO CONNECT NO CONNECT NO CONNECT Conversion Module Installation and Application Considerations c This Bul. 1492 cable consists of a cable wired to two 1756-IF6I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IF6I [1492-CONACAB005T2] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e The 1771-IL input configuration was software configured, as is the 1756-IF6I. Please ensure the correct configuration in the 1756-IF6I. f Refer to your 1771-IL and 1756-IF6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. g This configuration uses two (2) 1756-IF6I output modules to replace a single 1771-IL output module. This may require the use of a larger 1756 I/O chassis and conversion mounting assembly. Ensure there is sufficient panel space to allow for this possibility. 41171-031 (00) 90 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-IR to 1756-IRT8I WARNING IMPORTANT There are several key application considerations and system sp cations (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation. Cable 2-Wire RTD 3-Wire RTD Channel1 - C Channel1 - B Channel1 - A Channel2 - C Channel2 - B Channel2 - A Channel3 - C Channel3 - B Channel3 - A Channel4 - C Channel4 - B Channel4 - A Channel5 - C Channel5 - B Channel5 - A Channel6 - C Channel6 - B Channel6 - A 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 17 16 15 14 13 12 11 10 6 4 3 10 8 7 14 12 11 18 16 15 22 20 19 26 24 23 9 8 7 6 5 4 3 2 1 SH 1 2 5 9 13 17 21 25 27 IN_0/RTD C IN_0(-)/B IN_0(+)A IN_1/RTD C IN_1(-)/B IN_1(+)/A IN_2/RTD C IN_2(-)/B IN_2(+)/A IN_3/RTD C IN_3(-)/B IN_3(+)/A IN_4/RTD C IN_4(-)/B IN_4(+)/A IN_5/RTD C IN_5(-)/B IN_5(+)/A N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 28 29 30 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Conversion Module Installation and Application Considerations Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M) shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IRT8I [1492-CONACAB005F8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. Refer to your 1771-IR and 1756-IRT8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 91 Wiring Diagrams - Analog Inputs and Outputs 1771-IR to 1756-IR6I WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1492-CM1771-LA004 2-Wire RTD 3-Wire RTD Channel1 - C Channel1 - B Channel1 - A Channel2 - C Channel2 - B Channel2 - A Channel3 - C Channel3 - B Channel3 - A Channel4 - C Channel4 - B Channel4 - A Channel5 - C Channel5 - B Channel5 - A Channel6 - C Channel6 - B Channel6 - A 1 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1492-CONACAB005F 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Orange/Red White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black Green/Black Red/Black White/Black Blue Orange Green Red White Black 1756-IR6I 5 3 1 6 4 2 11 9 7 12 10 8 19 17 15 20 18 16 RTN-0/C IN-0/B IN-0/A R TN-1/C IN-1/B IN-1/A RTN-2/C IN-2/B IN-2/A R TN-3/C IN-3/B IN-3/A RTN-4/C IN-4/B IN-4/A RTN-5/C IN-5/B IN-5/A SH 1 1771-WF Swing Arm CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA004 module. The pre-wired cable used between the 1492-CM1771-LA004 module and the 1756-IR6I [1492-CONACAB005F] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. 2 The 1771-IR input configuration was software configured, as is the 1756-IR6I. Please ensure the correct configuration in the 1756-IR6I. 3 Refer to your 1771-IR and 1756-IR6I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41170-950 (1) 92 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-IXE to 1756-IT6I2 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1492-CM1771-LA005 Thermocouple + - 1756-IT6I2 1492-CONACAB005G Input 1+ Input 1Input 2+ Input 2Input 3+ Input 3Input 4+ Input 4- Input 5+ Input 5Input 6+ Input 6- 1 T 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 18 17 16 15 14 13 12 11 10 9 8 7 6 5 Orange/Red White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black Green/Black Red/Black White/Black Blue Orange 5 6 7 8 9 10 11 12 13 14 15 16 3 4 4 3 2 1 IN-0 RTN-0 IN-1 RTN-1 IN-2 RTN-2 IN-3 RTN-3 IN-4 RTN-4 IN-5 RTN-5 CJC+ CJC- SH 1 1771-WI Swing Arm CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA005 module. The pre-wired cable used between the 1492-CM1771-LA005 module and the 1756-IT6I2 [1492-CONACAB005G] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. 2 The 1771-IXE has 8 input channels. The 1756-IT6I2 only has 6 input channels. This module combination can only be used to convert the signals if 6 or less channels were used on the 1771-IXE. 3 The 1771-IXE has built CJC (cold junction compensation) into the swing-arm. The conversion module [1492-CM1771-LA005] passes this CJC signal to the 1756-IT6I2. Ensure that the 1756-IT6I2 is configured for external CJC. 4 The 1771-IXE input configuration was software configured, as is the 1756-IT6I2. Please ensure the correct configuration in the 1756-IT6I2. 5 Refer to your 1771-IXE and 1756-IT6I2 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41170-951 (1) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 93 Wiring Diagrams - Analog Inputs and Outputs 1771-IXE to 1756-IRT8I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module , cable and input module). Read and understand these considerations bef ore installation. Conversion Module Cable 1492-CM1771-LA005 SER “B” Thermocouple + - In_CH0+ In_CH0In_CH1+ In_CH1In_CH2+ In_CH2In_CH3+ In_CH3CJC+ CJCIn_CH4+ In_CH4In_CH5+ In_CH5In_CH6+ In_CH6In_CH7+ In_CH7- T 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1756-IRT8I 1492-CONACAB005G8 18 17 16 15 14 13 12 11 10 9 8 7 6 5 Orange/Red 4 3 2 1 Red/Black White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black Green/Black Red/Black White/Black Blue Orange White/Black Blue Orange SH 3 4 7 8 11 12 15 16 19 20 23 24 1 2 27 28 31 32 In_CH0+ In_CH0In_CH1+ In_CH1In_CH2+ In_CH2In_CH3+ In_CH3In_CH4+ In_CH4In_CH5+ In_CH5CJC+ CJCIn_CH6+ In_CH6In_CH7+ In_CH75 6 9 10 13 14 17 N.C. N.C. N.C. N.C. N.C. N.C. N.C. 18 21 22 25 26 29 30 1771-WI Swing Arm From 1771-IXE CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS This Bul. 1492 cable consists of a cable wired to one 1756-IRT8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA005 SER”B” module. The pre-wired cable used between the 1492-CM1771-LA005 SER”B” module and the 1756-IRT8I [1492-CONACAB005G8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. The 1771-IXE has built CJC (cold junction compensation) into the swing-arm. The conversion module [1492-CM1771-LA005 SER”B”] passes this CJC signal to the 1756-IRT8I. Ensure that the 1756-IRT8I is configured for external CJC. The 1771-IXE input configuration was software configured, as is the 1756-IRT8I. Please ensure the correct configuration in the 1756-IRT8I. Refer to your 1771-IXE and 1756-IRT8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 94 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 N.C. N.C. N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - Analog Inputs and Outputs 1771-IXHR to 1756-IT6I2 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module Cable 1492-CM1771-LA005 Thermocouple + - Input 1+ Input 1Input 2+ Input 2Input 3+ Input 3Input 4+ Input 4- T Input 5+ Input 5Input 6+ Input 6- d 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1492-CONACAB005G 18 17 16 15 14 13 12 11 10 9 8 7 6 5 c Orange/Red White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black Green/Black Red/Black White/Black Blue Orange 1756-IT6I2 5 6 7 8 9 10 11 12 13 14 15 16 3 4 4 3 2 1 IN-0 RTN-0 IN-1 RTN-1 IN-2 RTN-2 IN-3 RTN-3 IN-4 RTN-4 IN-5 RTN-5 CJC+ CJC- SH d 1771-WI Swing Arm From 1771-IXHR CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c This Bul. 1492 cable consists of a cable wired to one 1756-IT6I2 RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). See table 2 for other lengths. d SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA005 module. The pre-wired cable used between the 1492-CM1771-LA005 module and the 1756-IT6I2 [1492-CONACAB005G] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. e The 1771-IXHR has 8 input channels. The 1756-IT6I2 only has 6 input channels. This module combination can only be used to convert the signals if 6 or less channels were used on the 1771-IHER. f The 1771-IXHR has built CJC (cold junction compensation) into the swing-arm. The conversion module [1492-CM1771-LA005] passes this CJC signal to the 1756-IT6I2. Ensure that the 1756-IT6I2 is configured for external CJC. g The 1771-IXHR input configuration was software configured, as is the 1756-IT6I2. Please ensure the correct configuration in the 1756-IT6I2. h Refer to your 1771-IXHR and 1756-IT6I2 Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41171-035 (00) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 95 Wiring Diagrams - Analog Inputs and Outputs 1771-IXHR to 1756-IRT8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Conversion Module Cable 1492-CM1771-LA005 SER “B” Thermocouple + - In_CH0+ In_CH0In_CH1+ In_CH1In_CH2+ In_CH2In_CH3+ In_CH3CJC+ CJCIn_CH4+ In_CH4In_CH5+ In_CH5In_CH6+ In_CH6In_CH7+ In_CH7- T 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1756-IRT8I 1492-CONACAB005G8 18 17 16 15 14 13 12 11 10 9 8 7 6 5 Orange/Red 4 3 2 1 Red/Black White/Red Black/Red Blue/White Green/White Red/White Black/White Blue/Black Orange/Black Green/Black Red/Black White/Black Blue Orange White/Black Blue Orange SH 3 4 7 8 11 12 15 16 19 20 23 24 1 2 27 28 31 32 In_CH0+ In_CH0In_CH1+ In_CH1In_CH2+ In_CH2In_CH3+ In_CH3In_CH4+ In_CH4In_CH5+ In_CH5CJC+ CJCIn_CH6+ In_CH6In_CH7+ In_CH75 6 9 10 13 14 17 N.C. N.C. N.C. N.C. N.C. N.C. N.C. 18 21 22 25 26 29 30 1771-WI Swing Arm From 1771-IXHR CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS This Bul. 1492 cable consists of a cable wired to one 1756-IRT8I RTB. Recommended cable lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M). SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA005 SER”B” module. The pre-wired cable used between the 1492-CM1771-LA005 SER”B” module and the 1756-IRT8I [1492-CONACAB005G8] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. The 1771-IXHR has built CJC (cold junction compensation) into the swing-arm. The conversion module [1492-CM1771-LA005 SER”B”] passes this CJC signal to the 1756-IRT8I. Ensure that the 1756-IRT8I is configured for external CJC. The 1771-IXHR input configuration was software configured, as is the 1756-IRT8I. Please ensure the correct configuration in the 1756-IRT8I. Refer to your 1771-IXHR and 1756-IRT8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 96 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 N.C. N.C. N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - Analog Inputs and Outputs 1771-OFE1 to 1756-OF6VI IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation. 1492-CM1771-LA003 Voltage Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used 1771-WC Swing Arm 1 A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1756-OF6VI 1492-CONACAB005E Red/White Green/Black/White Red/Black/White White/Black/Red Black/White/Red Orange/Green Blue/Red Orange/Red 1 5 2 6 7 11 8 12 15 19 16 20 13 14 OUT-0 RTN-0 OUT-1 RTN-1 OUT-2 RTN-2 OUT-3 RTN-3 OUT-4 RTN-4 Not Used Not Used Not Used Not Used SH 1 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF6VI [1492-CONACAB005E] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. 2 The 1771-OFE1 analog output range was configured by jumpers, the output range for the 1756-OF6VI is software configured. Please ensure the correct output range is configured in the 1756-OF6VI. 3 Refer to your 1771-OFE1 and 1756-OF6VI Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41170-949 (1) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 97 Wiring Diagrams - Analog Inputs and Outputs 1771-OFE1 to 1756-OF8I IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Voltage Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used 1771-WC Swing Arm From 1771-OFE1 A 0 1 2 3 4 5 6 7 B Cable 1492-CONACAB005E8V 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1756-OF8I 2 6 1 5 10 14 9 13 3 4 7 8 11 12 15 16 17 18 19 20 21 22 SH OUT_0/V RTN_0 OUT_1/V RTN_1 OUT_2/V RTN_2 OUT_3/V RTN_3 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 27 28 29 30 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Conversion Module Installation and Application Considerations Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M) shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-CONACAB005E8V] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and 98 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-OFE1(2) to 1756-OF8I IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1756-OF8I Conversion Module 1492-CM1771-LA003 Voltage Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 Voltage Load OUT_0/V RTN_0 OUT_1/V RTN_1 OUT_2/V RTN_2 OUT_3/V RTN_3 SH Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used 1771-WC Swing Arm From 1771-OFE1 Conversion Module 1492-CM1771-LA003 + - 2 6 1 5 10 14 9 13 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OFE1 1492-C005005E8V Cable “A” A 0 1 2 3 4 5 6 7 B Cable “B” 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 SH 18 22 17 21 26 30 25 29 3 4 7 8 11 12 15 16 19 20 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OF8I. OUT_4/V RTN_4 OUT_5/V RTN_5 OUT_6/V RTN_6 OUT_7/V RTN_7 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 27 28 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-C005005E8V] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and DIR 10002306858 (Version 00) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 99 Wiring Diagrams - Analog Inputs and Outputs 1771-OFE2 to 1756-OF6CI WARNING IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and output module). Read and understand these considerations before installation. 1492-CM1771-LA003 Current Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used 1771-WC Swing Arm 1 A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1756-OF6CI 1492-CONACAB005E Red/White Green/Black/White Red/Black/White White/Black/Red Black/White/Red Orange/Green Blue/Red Orange/Red 1 5 2 6 7 11 8 12 15 19 16 20 13 14 OUT-0 RTN-0 OUT-1 RTN-1 OUT-2 RTN-2 OUT-3 RTN-3 OUT-4 RTN-4 Not Used Not Used Not Used Not Used SH 1 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 SHIELD GROUNDING: In some installations, the field wiring shield was grounded on the 1771 chassis. If this was the case, the installer must remove these shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF6CI [1492-CONACAB005E] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. 2 IMPORTANT: The 1771-OFE2 module required the use of an external power supply to drive the analog device. The 1756-OF6CI analog output provides the drive power to the analog device. ENSURE the external power supply is REMOVED from the current loop before applying power to the 1756-OF6CI module or the analog output module may be damaged. 3 The 1771-OFE2 analog output ranges were factory set, the output range for the 1756-OF6CI is software configured. Please ensure the correct output range is configured in the 1756-OF6CI. 4 The 1756-OF6CI module can drive a load up to 550 ohms with the standard pre-configured cable [1492-CONACAB005E]. If greater than a 550 ohm drive current is required, the pre-wired cable can be modified at the 1756-OF6CI terminal block to drive up to a 1000 ohms. Refer to the 1756-OF6CI Installation Manual for modification details. 5 Refer to your 1771-OFE2 and 1756-OF6CI Installation and User Manuals for additional information concerning comparisons of module wiring, features and configuration details. 41170-948 (1) 100 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - Analog Inputs and Outputs 1771-OFE2 to 1756-OF8I WARNING IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. Conversion Module 1492-CM1771-LA003 Current Load Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used + - 1771-WC Swing Arm From 1771-OFE2 A 0 1 2 3 4 5 6 7 B Cable 1492-CONACAB005E8C 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1756-OF8I 4 6 3 5 12 14 11 13 1 2 7 8 9 10 15 16 17 18 19 20 21 22 SH OUT_0/I RTN_0 OUT_1/I RTN_1 OUT_2/I RTN_2 OUT_3/I RTN_3 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 27 28 29 30 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Conversion Module Installation and Application Considerations Cables are available in lengths of 0.5M or 1.0M (005=0.5M, 010=1.0M) shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-CONACAB005E8C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. Refer to your 1771-OFE1 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and DIR 10002306853 (Version 00) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 101 Wiring Diagrams - Analog Inputs and Outputs 1771-OFE2(2) to 1756-OF8I IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1756-OF8I Conversion Module 1492-CM1771-LA003 Current Load + - Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used A 0 1 2 3 4 5 6 7 B 13 25 24 23 22 21 19 18 17 16 Current Load OUT_0/I RTN_0 OUT_1/I RTN_1 OUT_2/I RTN_2 OUT_3/I RTN_3 SH Channel 1 Out + Channel 1 Out Channel 2 Out + Channel 2 Out Channel 3 Out + Channel 3 Out Channel 4 Out + Channel 4 Out Not Used Not Used 1771-WC Swing Arm From 1771-OFE1 Conversion Module 1492-CM1771-LA003 + - 4 6 3 5 12 14 11 13 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 1771-WC Swing Arm From 1771-OFE1 1492-C005005E8C Cable “A” A 0 1 2 3 4 5 6 7 B Cable “B” 13 25 24 23 22 21 19 18 17 16 1 2 3 4 5 6 7 8 9 10 11 12 14 15 20 SH 20 22 19 21 28 30 27 29 1 2 7 8 15 16 15 16 17 18 Conversion Module Installation and Application Considerations This Bul. 1492 cable consists of 2 separate cables (cable “A” and cable “B”) wired to one 1756-OF8I. OUT_4/I RTN_4 OUT_5/I RTN_5 OUT_6/I RTN_6 OUT_7/I RTN_7 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Each cable can be either 0.5M or 1.0M (005=0.5M, 010=1.0M). Ensure that cable A and cable B are connected to the correct module in the conversion. shield connections from the 1771 chassis and they can be connected to the grounding stud on the 1492-CM1771-LA003 module. The pre-wired cable used between the 1492-CM1771-LA003 module and the 1756-OF8I [1492-C005005E8C] provides a shield ground lug to ground the shield at the 1756 ControlLogix chassis, this must be connected. Do NOT connect this ground lug to the conversion module grounding stud. Refer to your 1771-OFE2 and 1756-OF8I Installation and User Manuals for additional information concerning comparisons of module wiring, features and DIR 10002306859 (Version 00) 102 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - High Resolution Isolated Analog Standard High Resolution I/O 1771-NOC to 1756-OF8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Modul e 1771-RTP3 or 1771-RTP4 2 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 CURRENT LOAD R1 I1 O1 S1 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 1492-CONACAB020N88 Cable”B” 15 29 RTN_7 4 18 27 OUT_7/I 30 RTN_6 7 21 28 OUT_6/I 21 RTN_5 10 24 19 OUT_5/I 22 RTN_4 13 20 OUT_4/I Cable”A” 15 13 RTN_3 4 18 11 OUT_3/I 14 RTN_2 7 21 12 OUT_2/I 5 RTN_1 10 24 3 OUT_1/I 6 RTN_0 13 4 OUT_0/I 3 1 2 7 8 9 10 15 16 17 18 Interface Module Installation and Application Considerations N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row terminals, of B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. cable does not connect to these terminals. [Reference Doc: DIR 10002306650] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 103 Wiring Diagrams - High Resolution Isolated Analog 1771-NOC to 1756-OF8 There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT 1756-OF8 RTP3 OR RTP4 5 2 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 CURRENT LOAD R1 I1 O1 S1 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 6 1492-CONACAB020N8 Cable”B” 15 16 White/Red 4 18 19 Orange 7 21 22 White/Orange 10 24 25 13 Gray 19 I-OUT-3 15 I-RTN Green 13 I-OUT-2 White/Black Black 9 I-OUT-1 5 I-RTN White 3 I-OUT-0 1492-CONACAB020N8 Cable”A” 15 White/Red 4 18 Orange 7 21 White/Orange 10 24 Gray 4 19 I-OUT-3 15 I-RTN Green 13 I-OUT-2 White/Black 9 I-OUT-1 5 I-RTN Black 3 I-OUT-0 13 White 3 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 Cables are available in 2.0m, or 5.0m 2 Terminals starting with A are the lower row of terminals, B terminals are the upper row. 3 Follow your PLC Analog User Manual for proper shield grounding instructions. 4 RTN terminals are internally connected on the 1756-OF8. 5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only true for modules RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. 6 The 1771 - NOC module provides channel to channel isolation, the 1756-OF8 does not. A conversion from 1771-NOC to an isolated 1756-OF8 is avalible. 104 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-079 (00) Wiring Diagrams - High Resolution Isolated Analog 1771-NOC to 1756-OF6CI There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP3 or RTP4 g d SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 + CURRENT LOAD - W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 Cable “B” 1492-CONACAB020N1c N/A N/A 1756-OF6CI N/A 15 White/Red 12 4 18 Orange 8 11 7 21 White/Orange 10 24 Gray Black 2 5 OUT-1 RTN-0 13 White 1 OUT-0 Green Cable “A” 1492-CONACAB020N1c N/A N/A f OUT-3 RTN-2 7 OUT-2 6 RTN-1 White/Black N/A RTN-3 1756-OF6CI 15 White/Red 12 4 18 Orange 8 11 7 21 White/Orange 10 24 Gray Green RTN-3 f OUT-3 RTN-2 7 OUT-2 6 RTN-1 White/Black Black 13 White 2 5 OUT-1 RTN-0 1 OUT-0 e Conversion Module Installation and Application Considerations c Cables are available in 2.0m, or 5.0m d Terminals starting with A are the lower row of terminals, B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f RTN terminals are internally connected on the 1756-OF6CI. g Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for modules RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. [Reference Doc: 41171-072 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 105 Wiring Diagrams - High Resolution Isolated Analog 1771-NIS to 1756-IF8I WARNING IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. Interface Module 2 24VDC SUPPLY CURRENT LOAD + CURRENT LOAD + 24VDC SUPPLY N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 4 - N/A N/A c 1492-CONACAB020N38 CABLE “B” 15 16 29 27 RTN_7 18 19 30 28 RTN_6 21 22 21 19 RTN_5 24 25 22 20 RTN_4 15 16 13 11 RTN_3 18 19 14 12 RTN_2 21 22 5 3 RTN_1 24 25 6 4 RTN_0 N/A N/A IN_6/I/SRC IN_5/I/SRC IN_4/I/SRC CABLE “A” 3 Interface Module Installation and Application Considerations c Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) d Terminals starting with A are the lower row terminals, of B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f for module RTP4. The Bul. 1492 cable does not connect t o t hese t erminals. DIR 10002306457 (Version 00) 106 IN_7/I/SRC Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 1 2 7 8 9 10 15 16 17 18 IN_3/I/SRC IN_2/I/SRC IN_1/I/SRC IN_0/I/SRC N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - High Resolution Isolated Analog 1771-NIS to 1756-IF6CIS using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT 1771-RTP4 2 LOOP POWER SUPPLIED INTERNALLY + CURRENT LOAD - USER SUPPLIED LOOP POWER SUPPLIED INTERNALLY 24VDC SUPPLY CURRENT LOAD CURRENT LOAD + + - 24VDC SUPPLY R4 I4 O4 S4 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 S1 O1 R0 I0 O0 S0 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 SH W2 W3 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 S5 O5 5 - CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS N/A N/A 1492-CONACAB020N2 1756-IF6CIS Cable “B” N/A 4 15 16 White/Red 4 18 19 White/Green 7 21 22 10 24 25 13 Red Green Yellow Brown White/Brown Black Violet White/Violet 1492-CONACAB020N2 N/A Cable “A” 15 16 White/Red 4 18 19 White/Green 7 21 22 10 24 25 13 8 V-OUT-7 11 I-RTN-6 9 I-IN-6 White/Yellow White/Black N/A N/A 12 I-RTN-7 10 I-IN-7 Red Green Yellow White/Yellow White/Black Brown White/Brown Black Violet White/Violet 7 6 4 V-OUT-6 I-RTN-5 I-IN-5 2 5 3 1 V-OUT-5 I-RTN-4 I-IN-4 V-OUT-4 1756-IF6CIS 12 I-RTN-3 4 10 I-IN-3 8 V-OUT-3 11 I-RTN-2 9 I-IN-2 7 6 4 V-OUT-2 I-RTN-1 I-IN-1 2 5 3 1 V-OUT-1 I-RTN-0 I-IN-0 V-OUT-0 3 1 Cables are available in 2.0m, or 5.0m 2 Terminals starting with A are the lower row of terminals, B terminals are the upper row. 3 Follow your PLC Analog User Manual for proper shield grounding instructions. 4 RTN terminals are internally connected on the 1756-IF6CIS. 5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only true for modules RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-073 (01) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 107 Wiring Diagrams - High Resolution Isolated Analog 1771-NIV to 1756-IF8I — Current There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP3 4 2 + 24VDC SUPPLY CURRENT LOAD CURRENT LOAD + - 24VDC SUPPLY N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 - 1492-CONACAB020N38 CABLE “B” N/A N/A 15 16 18 19 21 22 24 25 N/A 15 16 21 22 24 25 3 Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306458 (Version 00) 108 29 27 RTN_7 30 28 RTN_6 21 19 RTN_5 22 20 RTN_4 13 11 RTN_3 14 12 RTN_2 5 3 RTN_1 6 4 RTN_0 IN_7/I/SRC IN_6/I/SRC IN_5/I/SRC IN_4/I/SRC CABLE “A” N/A 18 19 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 1 2 7 8 9 10 15 16 17 18 IN_3/I/SRC IN_2/I/SRC IN_1/I/SRC IN_0/I/SRC N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - High Resolution Isolated Analog 1771-NIV to 1756-IF6I — Current IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1771-RTP4 5 2 + 24VDC SUPPLY CURRENT LOAD CURRENT LOAD + - 24VDC SUPPLY N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 - 1492-CONACAB010N3 CABLE “B” N/A N/A 15 16 White/Red 18 19 Green 21 22 White/Black 24 25 White Black N/A 1492-CONACAB010N3 CABLE “A” N/A N/A 11 RTN-2 9 IN-2/I 7 IN-2/V White/Orange Gray White/Red 18 19 Green 21 22 White/Black 24 25 White Black 4 12 RTN-3 10 IN-3/I 8 IN-3/V Orange 15 16 1756-IF6I 6 4 2 RTN-1 IN-1/I IN-1/V 5 3 1 RTN-0 IN-0/I IN-0/V 1756-IF6I 12 RTN-3 10 IN-3/I 8 IN-3/V Orange 4 11 RTN-2 9 IN-2/I 7 IN-2/V White/Orange Gray 6 4 2 RTN-1 IN-1/I IN-1/V 5 3 1 RTN-0 IN-0/I IN-0/V 3 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 Cables are available in 2.0m, or 5.0m 2 Terminals starting with A are the lower row of terminals, B terminals are the upper row. 3 Follow your PLC Analog User Manual for proper shield grounding instructions. 4 RTN terminals are internally connected on the 1756-IF6I. 5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only true for modules RTP3. The Bul. 1492 cable does not connect to these terminals. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-074 (00) 109 Wiring Diagrams - High Resolution Isolated Analog 1771-NIV to 1756-IF8I — Voltage There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP4 4 2 + VOLTAGE LOAD - VOLTAGE LOAD N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 1492-CONACAB020N78 CABLE “B” N/A N/A 15 16 18 19 21 22 24 25 N/A 15 16 21 22 24 25 3 Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. for module RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306478 (Version 00) 110 29 25 RTN_7 30 26 RTN_6 21 17 RTN_5 22 18 RTN_4 13 9 RTN_3 14 10 RTN_2 5 1 RTN_1 6 2 RTN_0 IN_7/V IN_6/V IN_5/V IN_4/V CABLE “A” N/A 18 19 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 3 4 7 8 11 12 15 16 19 20 IN_3/V IN_2/V IN_1/V IN_0/V N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 27 28 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - High Resolution Isolated Analog 1771-NIV to 1756-IF6I — Voltage There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP4 or 1771-RTP4 g d VOLTAGE LOAD VOLTAGE LOAD + + R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 1756-IF6I Cable “B” 1492-CONACAB020N7c N/A N/A N/A 15 16 White/Red 19 18 Yellow 22 21 Brown 24 25 Black Violet Green 6 2 RTN-1 IN-1V 5 1 RTN-0 IN-0V Cable “A” 1492-CONACAB020N7c N/A N/A White/Red Yellow 21 22 Brown Green 24 25 1756-IF6I 12 RTN-3 8 IN-3V Red 18 19 f 11 RTN-2 7 IN-2V White/Black N/A 15 16 12 RTN-3 8 IN-3V Red f 11 RTN-2 7 IN-2V White/Black Black Violet 6 2 RTN-1 IN-1V 5 1 RTN-0 IN-0V e Conversion Module Installation and Application Considerations c Cables are available in 2.0m, or 5.0m d Terminals starting with A are the lower row of terminals, B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f RTN terminals are internally connected on the 1756-IF6I. g Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-080 Ver (00) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 111 Wiring Diagrams - High Resolution Isolated Analog 1771-NIV to 1756-IF6I — Current and Voltage There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP4 g d VOLTAGE LOAD CURRENT LOAD + + R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 1756-IF6I Cable “B” 1492-CONACAB020N7c N/A N/A (Voltage) N/A 15 16 White/Red 12 RTN-3 8 IN-3V Red 19 18 Yellow 22 21 Brown 24 25 Black Violet Green 11 RTN-2 7 IN-2V White/Black CABLE “A” c 1492-CONACAB010N3 N/A N/A f 6 2 RTN-1 IN-1V 5 1 RTN-0 IN-0V 1756-IF6I (Current) N/A 15 16 White/Red 18 19 Green Green Yellow White/Orange 21 22 Brown Gray 24 25 Black White Violet Black 12 RTN-3 10 IN-3/I 8 IN-3/V Red Orange 11 RTN-2 9 IN-2/I 7 IN-2/V White/Black White/Black 6 4 2 RTN-1 IN-1/I IN-1/V 5 3 1 RTN-0 IN-0/I IN-0/V 3 Conversion Module Installation and Application Considerations c Cables are available in 2.0m, or 5.0m d Terminals starting with A are the lower row of terminals, B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f RTN terminals are internally connected on the 1756-IF6I. g Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-039 Ver (00) 112 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 4 Wiring Diagrams - High Resolution Isolated Analog 1771-NIV to 1756-IF6I — Voltage and Current There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT 1771-RTP4 5 2 CURRENT LOAD + Voltage LOAD + N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 1492-CONACAB010N3 CABLE “B” N/A 15 16 White/Red 18 19 Green 21 22 White/Black 24 25 White Black N/A 1756-IF6I (Current) N/A 12 RTN-3 10 IN-3/I 8 IN-3/V Orange 4 11 RTN-2 9 IN-2/I 7 IN-2/V White/Orange Gray 6 4 2 RTN-1 IN-1/I IN-1/V 5 3 1 RTN-0 IN-0/I IN-0/V 1492-CONACAB010N7 CABLE “A” 1756-IF6I (Voltage) N/A 15 16 White/Red 18 19 Green 21 22 White/Black 24 25 White Black 12 RTN-3 8 IN-3V Orange f 11 RTN-2 7 IN-2V White/Orange Gray 6 2 RTN-1 IN-1V 5 1 RTN-0 IN-0V 3 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 Cables are available in 2.0m, or 5.0m 2 Terminals starting with A are the lower row of terminals, B terminals are the upper row. 3 Follow your PLC Analog User Manual for proper shield grounding instructions. 4 RTN terminals are internally connected on the 1756-IF6I. 5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only true for modules RTP3. The Bul. 1492 cable does not connect to these terminals. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-038 (00) 113 Wiring Diagrams - High Resolution Isolated Analog 1771-NR to 1756-IRT8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP4 4 2 RTD TRANSMITTER RTD TRANSMITTER R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 N/A 1492-CONACAB020N48 Cable “B” N/A N/A 15 16 4 18 19 31 IN_7(+)/A 30 IN_6/RTD C 28 IN_6(-)/B 34 IN_7/RTD C 32 IN_7(-)/B 7 21 22 10 24 25 13 27 IN_6(+)/A 26 IN_5/RTD C 24 IN_5(-)/B 23 IN_5(+)/A 22 IN_4/RTD C 20 IN_4(-)/B 19 IN_4(+)/A N/A Cable “A” N/A N/A 15 16 4 18 19 15 IN_3(+)/A 14 IN_2/RTD C 12 IN_2(-)/B 11 IN_2(+)/A 10 IN_1/RTD C 8 IN_1(-)/B 18 IN_3/RTD C 16 IN_3(-)/B 7 21 22 10 24 25 13 7 IN_1(+)/A 6 IN_0/RTD C IN_0(-)/B 4 3 IN_0(+)/A 3 1 2 5 9 13 17 21 N.C. N.C. N.C. N.C. N.C. N.C. N.C. Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306848 (Version 00) 114 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 25 29 33 35 36 N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - High Resolution Isolated Analog 1771-NR to 1756-IR6I There are several key application considerations and system specifications (bottom using these components (conversion module, cable and input module). Read and considerations before installation. IMPORTANT 1771-RTP4 5 2 RTD TRANSMITTER RTD TRANSMITTER R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 N/A N/A N/A 15 16 White/Red 4 18 19 Orange 7 21 22 White/Orange 10 24 25 13 Gray Black N/A 1492-CONACAB020N4 Cable “A” N/A N/A 1756-IR6I 1492-CONACAB020N4 Cable “B” 12 RTN-3 4 10 IN-3/B Red 8 IN-3/A 11 RTN-2 9 IN-2/B Green Yellow 7 White/Black Brown 5 3 1 Violet White 15 16 White/Red 4 18 19 Orange 7 21 22 White/Orange 10 24 25 13 Gray Black IN-2/A 6 RTN-1 4 IN-1/B 2 IN-1/A RTN-0 IN-0/B IN-0/A 1756-IR6I 12 RTN-3 4 10 IN-3/B Red 8 IN-3/A 11 RTN-2 9 IN-2/B Green Yellow 7 White/Black Brown 5 3 1 Violet White IN-2/A 6 RTN-1 4 IN-1/B 2 IN-1/A RTN-0 IN-0/B IN-0/A 3 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 Cables are available in 2.0m, or 5.0m 2 Terminals starting with A are the lower row of terminals, B terminals are the upper row. 3 Follow your PLC Analog User Manual for proper shield grounding instructions. 4 RTN terminals are internally connected on the 1756-IR6I. 5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only true for modules RTP4. The Bul. 1492 cable does not connect to these terminals. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-075 (00) 115 Wiring Diagrams - High Resolution Isolated Analog 1771-NT1 or -NT2 to 1756-IRT8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RT41 4 2 THERMOCOUPLE + B1 A1 B2 B3 A2 A3 B4 B5 A4 A5 SH W1 R4 I4 S4 O4 R3 I3 S3 O3 Thermocouple B6 B7 A6 A7 B8 B9 A9 A8 R2 I2 S2 O2 R1 I1 O1 S1 1 1756-IRT8I 1492-CONACAB020N68 Cable “B” 15 16 White/Red 18 19 Green 32 IN_7(-)/B 31 IN_7(+)/A Red 28 IN_6(-)/B 27 IN_6(+)/A Yellow 14 White/Violet 1 White/Grey 36 CJC1 21 22 White/Black Brown 24 IN_5(-)/B 23 IN_5(+)/A 24 25 35 CJC1 Black 20 IN_4(-)/B 19 IN_4(+)/A Violet 3 Interface Module 1771-RT41 4 2 THERMOCOUPLE + B1 A1 B2 B3 A2 A3 B4 B5 A4 A5 SH W1 R4 I4 S4 O4 R3 I3 S3 O3 Thermocouple R2 I2 S2 O2 R1 I1 O1 S1 B6 B7 A6 A7 B8 B9 A9 A8 Cable “A” 15 16 White/Red 18 19 Green 16 IN_3(-)/B 15 IN_3(+)/A Red 12 IN_2(-)/B 11 IN_2(+)/A Yellow 14 White/Violet 1 CJC0 1 White/Grey 2 CJC0 21 22 White/Black Brown 8 IN_1(-)/B 7 IN_1(+)/A 24 25 Black 4 IN_0(-)/B 3 IN_0(+)/A Violet 3 5 6 9 10 13 14 17 N.C. N.C. N.C. N.C. N.C. N.C. N.C. 18 21 22 25 26 29 30 33 34 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. This conversion solution requires replacement of the exisiting (1) 1771-RTP1 interface module with (2) 1771-RT41 interface modules. Each 1771-RTP1 and RT41 module has there own cold junction compensation thermocouple attached to the interface module. DIR 10002306849 (Version 00) 116 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - High Resolution Isolated Analog 1771-NT1 to 1756-IT6I There are several key application considerations and system specifications (bottom using these components (conversion module, cable and input module). Read and considerations before installation. IMPORTANT 1771-RT41 4 2 THERMOCOUPLE + SH W1 R4 I4 S4 O4 R3 I3 S3 O3 1 Cable “B” B1 A1 B2 B3 A2 A3 B4 B5 A4 A5 15 16 White/Red 18 19 Green Thermocouple R2 I2 S2 O2 R1 I1 O1 S1 1756-IT6I 1492-CONACAB020N5 B6 B7 A6 A7 B8 B9 A9 A8 21 22 24 25 12 RTN-3 8 IN-3 Red 11 RTN-2 7 IN-2 Yellow White/Violet 10 CJC+ White/Grey 14 CJC- White/Black Brown Black Violet 6 2 RTN-1 IN-1 5 1 RTN-0 IN-0 3 1771-RT41 4 2 THERMOCOUPLE + SH W1 R4 I4 S4 O4 R3 I3 S3 O3 B1 A1 B2 B3 A2 A3 B4 B5 A4 A5 1 1492-CONACAB020N5 15 16 White/Red 18 19 Green Thermocouple R2 I2 S2 O2 R1 I1 O1 S1 B6 B7 A6 A7 B8 B9 A9 A8 1756-IT6I Cable “A” 21 22 24 25 12 RTN-3 8 IN-3 Red 11 RTN-2 7 IN-2 Yellow White/Violet 10 CJC+ White/Grey 14 CJC- White/Black Brown Black Violet 6 2 RTN-1 IN-1 5 1 RTN-0 IN-0 3 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c Cables are available in 2.0M or 5.0M. dTerminals starting with A are the lower row of terminals, B terminals are the upper row. eFollow your PLC Analog User Manual for proper shield grounding instructions. fTerminals W1, W2 and W3 are spares used for field wire convenience. NOTE. This is only true for modules RT41 . The Bul. 1492 cable does not connect to these terminals. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-076 (01) 117 Wiring Diagrams - High Resolution Isolated Analog 1771-NOV to 1756-OF8I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Interface Module 1771-RTP3 or 1771-RTP4 2 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 VOLTAGE LOAD + W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 1492-CONACAB020N18 Cable”B” 15 4 18 7 21 10 24 13 25 OUT_7/V 30 RTN_6 26 OUT_6/V 21 RTN_5 29 RTN_7 17 OUT_5/V 22 RTN_4 18 OUT_4/V Cable”A” 15 4 18 7 21 10 24 9 OUT_3/V 14 RTN_2 10 OUT_2/V 5 RTN_1 1 OUT_1/V 6 RTN_0 13 RTN_3 2 OUT_0/V 13 3 1 2 7 8 9 10 15 16 17 18 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 25 26 31 32 33 34 35 36 Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306686 (Version 00) 118 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - High Resolution Isolated Analog 1771-NOV to 1756-OF6VI There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP3 or RTP4 g d SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 VOLTAGE LOAD + R1 I1 O1 S1 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 Cable “B” 1492-CONACAB020N1c N/A N/A 1756-OF6VI N/A 15 White/Red 12 4 18 Orange 8 11 7 21 White/Orange 10 24 Gray Black 2 5 OUT-1 RTN-0 13 White 1 OUT-0 Green Cable “A” 1492-CONACAB020N1c N/A N/A f OUT-3 RTN-2 7 OUT-2 6 RTN-1 White/Black N/A RTN-3 1756-OF6VI 15 White/Red 12 4 18 Orange 8 11 7 21 White/Orange 10 24 Gray Green RTN-3 f OUT-3 RTN-2 7 OUT-2 6 RTN-1 White/Black Black 13 White 2 5 OUT-1 RTN-0 1 OUT-0 e Conversion Module Installation and Application Considerations c Cables are available in 2.0m, or 5.0m d Terminals starting with A are the lower row of terminals, B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f RTN terminals are internally connected on the 1756-OF6VI. g Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for modules RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-081 Ver(00) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 119 Wiring Diagrams - High Resolution Isolated Analog 1771-NIV1 to 1756-IF8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP4 4 2 VOLTAGE LOAD + VOLTAGE LOAD + N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 N/A 15 16 18 19 30 26 RTN_6 21 17 RTN_5 22 18 RTN_4 13 9 RTN_3 14 10 RTN_2 5 1 RTN_1 6 2 RTN_0 24 25 N/A IN_7/V IN_6/V IN_5/V IN_4/V CABLE “A” N/A 15 16 21 22 3 Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306486 (Version 00) 120 RTN_7 21 22 24 25 29 25 18 19 1492-CONACAB020N78 CABLE “B” N/A Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 3 4 7 8 11 12 15 16 19 20 IN_3/V IN_2/V IN_1/V IN_0/V N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. 23 24 27 28 31 32 33 34 35 36 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Wiring Diagrams - High Resolution Isolated Analog 1771-NIV1 to 1756-IF6I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1756-IF6I RTP4 5 2 VOLTAGE LOAD + VOLTAGE LOAD + R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 1492-CONACAB020N7 N/A N/A Cable”B” N/A 15 16 White/Red 19 18 Yellow 22 21 Brown 24 25 Black Violet N/A N/A N/A 12 RTN-3 4 8 IN-3V Red 7 RTN-2 13 IN-2V Green White/Black Cable”A” White/Red 19 18 Yellow 24 25 Black Violet Brown CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS 1 Cables are available in 2.0m, or 5.0m 2 Terminals starting with A are the lower row of terminals, B terminals are the upper row. 3 Follow your PLC Analog User Manual for proper shield grounding instructions. 4 RTN terminals are internally connected on the 1756-IF6I. 5 Terminals w1, w2, w3, are spares used f or field wire convenience. NOTE: this is only true for modules RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 RTN-0 IN-0V 4 7 RTN-2 13 IN-2V Green White/Black 5 1 12 RTN-3 8 IN-3V Red 22 21 RTN-1 IN-1V 1756-IF6I 1492-CONACAB020N7 15 16 2 6 2 6 RTN-1 IN-1V 5 1 RTN-0 IN-0V 3 41171-078 (00) 121 Wiring Diagrams - High Resolution Isolated Analog 1771-NT2 to 1756-IRT8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RT41 4 2 THERMOCOUPLE + B1 A1 B2 B3 A2 A3 B4 B5 A4 A5 SH W1 R4 I4 S4 O4 R3 I3 S3 O3 Thermocouple B6 B7 A6 A7 B8 B9 A9 A8 R2 I2 S2 O2 R1 I1 O1 S1 1 1756-IRT8I 1492-CONACAB020N68 Cable “B” 15 16 White/Red 18 19 Green 32 IN_7(-)/B 31 IN_7(+)/A Red 28 IN_6(-)/B 27 IN_6(+)/A Yellow 14 White/Violet 35 CJC1 1 White/Grey 36 CJC1 21 22 White/Black Brown 24 IN_5(-)/B 23 IN_5(+)/A 24 25 Black 20 IN_4(-)/B 19 IN_4(+)/A Violet 3 Interface Module 1771-RT41 4 2 THERMOCOUPLE + B1 A1 B2 B3 A2 A3 B4 B5 A4 A5 SH W1 R4 I4 S4 O4 R3 I3 S3 O3 Thermocouple R2 I2 S2 O2 R1 I1 O1 S1 B6 B7 A6 A7 B8 B9 A9 A8 Cable “A” 15 16 White/Red 18 19 Green 16 IN_3(-)/B 15 IN_3(+)/A Red 12 IN_2(-)/B 11 IN_2(+)/A Yellow 14 White/Violet 1 White/Grey 2 CJC0 21 22 White/Black Brown 8 IN_1(-)/B 7 IN_1(+)/A 24 25 1 CJC0 Black 4 IN_0(-)/B 3 IN_0(+)/A Violet 3 5 6 9 10 13 14 17 N.C. N.C. N.C. N.C. N.C. N.C. N.C. 18 21 22 25 26 29 30 33 34 N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. N.C. Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. This conversion solution requires replacement of the exisiting (1) 1771-RTP1 interface module with (2) 1771-RT41 interface modules. Each 1771-RTP1 and RT41 module has there own cold junction compensation thermocouple attached to the interface module. DIR 10002306849 (Version 00) 122 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - High Resolution Isolated Analog 1771-NT2 to 1756-IT6I2 IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. 1771-RT41 4 2 THERMOCOUPLE + SH W1 R4 I4 S4 O4 R3 I3 S3 O3 1 1756-IT6I2 1492-CONACAB020N6 Cable “B” B1 A1 B2 B3 A2 A3 B4 B5 A4 A5 15 16 White/Red 18 19 Green 12 RTN-3 11 IN-3 Red 10 RTN-2 9 IN-2 Yellow White/Violet Thermocouple R2 I2 S2 O2 R1 I1 O1 S1 B6 B7 A6 A7 B8 B9 A9 A8 White/Grey 21 22 24 25 White/Black Brown Black Violet 3 CJC+ 4 CJC- 8 7 RTN-1 IN-1 6 5 RTN-0 IN-0 3 1771-RT41 4 2 THERMOCOUPLE + SH W1 R4 I4 S4 O4 R3 I3 S3 O3 B1 A1 B2 B3 A2 A3 B4 B5 A4 A5 1 1492-CONACAB020N6 1756-IT6I2 Cable “A” 15 16 White/Red 18 19 Green 12 RTN-3 11 IN-3 Red 10 RTN-2 9 IN-2 Yellow White/Violet Thermocouple R2 I2 S2 O2 R1 I1 O1 S1 B6 B7 A6 A7 B8 B9 A9 A8 White/Grey 21 22 24 25 White/Black Brown Black Violet 3 CJC+ 4 CJC- 8 7 RTN-1 IN-1 6 5 RTN-0 IN-0 3 CONVERSION MODULE INSTALLATION AND APPLICATION CONSIDERATIONS c Cables are available in 2.0M or 5.0M. dTerminals starting with A are the lower row of terminals, B terminals are the upper row. eFollow your PLC Analog User Manual for proper shield grounding instructions. fTerminals W1, W2 and W3 are spares used for field wire convenience. NOTE. This is only true for modules RT41 . The Bul. 1492 cable does not connect to these terminals. Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 41171-077 (01) 123 Wiring Diagrams - High Resolution Isolated Analog Combination High Resolution I/O 1771-NIVR to1756-IRT8I and -IF8I IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. Interface Module 1771-RTP4 RTD ANSMITTER VOLTAGE LOAD + 1492-CONACAB020N44 N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 1756-IRT8I CABLE “B” N/A N/A 15 16 4 18 19 7 21 22 15 IN_3(+)/A 14 IN_2/RTD C 12 IN_2(-)/B 18 IN_3/RTD C 16 IN_3(-)/B 10 24 25 13 7 IN_1(+)/A IN_0/RTD C IN_0(-)/B IN_0(+)/A 6 4 3 1492-CONACAB020N74 1756-IF8I CABLE “A” N/A 15 16 13 RTN_3 9 IN_3/V 21 22 24 25 11 IN_2(+)/A 10 IN_1/RTD C 8 IN_1(-)/B N/A 18 19 14 RTN_2 10 IN_2/V 5 1 RTN_1 IN_1/V 6 2 RTN_0 IN_0/V Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306496(Version 00) 124 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - High Resolution Isolated Analog 1771-NIVR to 1756-IR6Iand -IF6I IMPORTANT There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. Interface Module 1771-RTP4 g d RTD TRANSMITTER VOLTAGE LOAD + N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 Cable “B” 1492-CONACAB020N4c N/A 1756-IR6I N/A 15 16 12 RTN-3 10 IN-3/B 4 18 19 8 IN-3/A 11 RTN-2 9 IN-2/B 7 21 22 7 10 24 25 13 IN-2/A 6 RTN-1 4 IN-1/B 2 IN-1/A RTN-0 IN-0/B IN-0/A 5 3 1 Cable “A” 1492-CONACAB020N7c N/A N/A 15 16 White/Red 18 19 Green Yellow 21 22 Brown 24 25 Black Violet 1756-IF6I 12 RTN-3 8 IN-3V Red f f 11 RTN-2 7 IN-2V White/Black 6 2 RTN-1 IN-1V 5 1 RTN-0 IN-0V e Conversion Module Installation and Application Considerations c Cables are available in 2.0m, or 5.0m d Terminals starting with A are the lower row of terminals, B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f RTN terminals are internally connected on the 1756-IF6I. g Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. [Reference Doc: 41171-082 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 125 Wiring Diagrams - High Resolution Isolated Analog 1771-NIVR to 1756-IRT8I and -IF8I IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. Interface Module 1771-RTP4 RTD TRANSMITTER CURRENT LOAD + 1492-CONACAB020N44 N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 1756-IRT8I CABLE “B” N/A N/A 15 16 4 18 19 7 21 22 15 IN_3(+)/A 14 IN_2/RTD C 12 IN_2(-)/B 18 IN_3/RTD C 16 IN_3(-)/B 10 24 25 13 11 IN_2(+)/A 10 IN_1/RTD C 8 IN_1(-)/B 6 4 3 1492-CONACAB020N34 N/A 15 16 13 RTN_3 11 IN_3/I/SRC 14 RTN_2 12 IN_2/I/SRC 21 22 24 25 1756-IF8I CABLE “A” N/A 18 19 7 IN_1(+)/A IN_0/RTD C IN_0(-)/B IN_0(+)/A 5 3 RTN_1 IN_1/I/SRC 6 4 RTN_0 IN_0/I/SRC Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306490 (Version 00) 126 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - High Resolution Isolated Analog 1771-NIVR to 1756-IR6I and -IF6I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP4 g d RTD TRANSMITTER VOLTAGE LOAD + N/A R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 N/A SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 Cable “B” 1492-CONACAB020N4c N/A 1756-IR6I N/A 15 16 12 RTN-3 10 IN-3/B 4 18 19 8 IN-3/A 11 RTN-2 9 IN-2/B 7 21 22 7 10 24 25 13 N/A N/A IN-2/A 6 RTN-1 4 IN-1/B 2 IN-1/A RTN-0 IN-0/B IN-0/A 5 3 1 Cable “A” 1492-CONACAB010N3c 15 16 White/Red 18 19 Green 21 22 White/Black 24 25 White Black 1756-IF6I 12 RTN-3 10 IN-3/I 8 IN-3/V Orange f f 11 RTN-2 9 IN-2/I 7 IN-2/V White/Orange Gray 6 4 2 RTN-1 IN-1/I IN-1/V 5 3 1 RTN-0 IN-0/I IN-0/V e Conversion Module Installation and Application Considerations c Cables are available in 2.0m, or 5.0m d Terminals starting with A are the lower row of terminals, B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f RTN terminals are internally connected on the 1756-IF6I. g Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. [Reference Doc: 41171-083 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 127 Wiring Diagrams - High Resolution Isolated Analog 1771-NIVT to 1756-IRT8I and -IF8I IMPORTANT using these components (conversion module, cable and input module). Read and understand these considerations before installation. Interface Module 1771-RTP1 4 2 THERMOCOUPLE + SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 CABLE “B” 1492-CONACAB020N54 15 16 White/Red 18 19 Green 21 22 16 IN_3(-)/B 15 IN_3(+)/A Red 12 IN_2(-)/B 11 IN_2(+)/A Yellow White/Black Brown Black 24 25 1756-IRT8I Violet 8 7 IN_1(-)/B IN_1(+)/A 4 3 IN_0(-)/B IN_0(+)/A 10 14 14 Thermocouple VOLTAGE LOAD + W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 CJC+ CJC- 1 CABLE “A” 1492-CONACAB020N74 15 16 18 19 13 RTN_3 9 IN_3/V 21 22 24 25 1756-IF8I 14 RTN_2 10 IN_2/V 5 1 RTN_1 IN_1/V 6 2 RTN_0 IN_0/V 3 Interface Module Installation and Application Considerations Cables are available in lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M) Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP3 and RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306594 (Version 00) 128 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - High Resolution Isolated Analog 1771-NIVT to 1756-IT6I and -IF6I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP1 4 2 THERMOCOUPLE + SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 1492-CONACAB010N5 CABLE “B” B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 15 16 White/Red 18 19 Green 21 22 White/Black 24 25 12 RTN-3 11 IN-3 Red 10 RTN-2 9 IN-2 Yellow Brown Black Violet VOLTAGE LOAD + A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 RTN-1 6 5 RTN-0 IN-0 14 14 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 8 7 10 CABLE “B” Thermocouple 1756-IT6I IN-1 CJC+ CJC- 1 Cable “A” 1492-CONACAB020N7c 15 16 White/Red 18 19 Green Yellow 21 22 Brown 24 25 Black Violet 1756-IF6I 12 RTN-3 8 IN-3V Red f 11 RTN-2 7 IN-2V White/Black 6 2 RTN-1 IN-1V 5 1 RTN-0 IN-0V 3 Conversion Module Installation and Application Considerations c Cables are available in 2.0m, or 5.0m d Terminals starting with A are the lower row of terminals, B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f RTN terminals are internally connected on the 1756-IF6I. g Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. [Reference Doc: 41171-084 (Version 00)] Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 129 Wiring Diagrams - High Resolution Isolated Analog 1771-NIVT to 1756-IRT8I and -IF8I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP1 4 2 THERMOCOUPLE + SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 CABLE “B” 1756-IRT8I 1492-CONACAB020N54 15 16 White/Red 18 19 Green 21 22 White/Black 16 IN_3(-)/B 15 IN_3(+)/A Red 12 IN_2(-)/B 11 IN_2(+)/A Yellow Brown Black 24 25 Violet 8 7 IN_1(-)/B 4 3 IN_0(-)/B IN_0(+)/A 10 14 14 Thermocouple CURRENT LOAD W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 + A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 IN_1(+)/A CJC+ CJC- 1 CABLE “A” 1756-IF8I 1492-CONACAB020N34 15 16 18 19 13 RTN_3 11 IN_3/I/SRC 14 RTN_2 12 IN_2/I/SRC 21 22 24 25 5 3 RTN_1 IN_1/I/SRC 6 4 RTN_0 IN_0/I/SRC 3 Interface Module Installation and Application Considerations This Bul. 1492 cable consists of a cable wired to one 1756-IF8I (or 1756-IRT8I). Recommended cable lengths of 2.0M or 5.0M (020=2.0M, 050=5.0M). See table 2 for other lengths. Terminals starting with A are the lower row of terminals, B terminals are the upper row. Follow your PLC Analog User Manual for proper shield grounding instructions. for module RTP4. The Bul. 1492 cable does not connect to these terminals. DIR 10002306504 (Version 00) 130 Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 Wiring Diagrams - High Resolution Isolated Analog 1771-NIVT to 1756-IT6I and -IF6I There are several key application considerations and system specifications (bottom of drawing) when using these components (conversion module, cable and input module). Read and understand these considerations before installation. IMPORTANT Interface Module 1771-RTP1 4 2 THERMOCOUPLE + SH W2 W3 R8 I8 S8 O8 R7 I7 S7 O7 R6 I6 S6 O6 R5 I5 O5 S5 1492-CONACAB010N5 CABLE “B” B1 B2 B3 B4 B5 A4 A5 B8 B9 A6 A7 B12 B13 A8 A9 B16 B17 A10 A11 15 16 White/Red 18 19 Green 21 22 24 25 12 RTN-3 8 IN-3 Red 11 RTN-2 7 IN-2 Yellow White/Black Brown Black Violet CURRENT LOAD + A1 A2 A3 B12 B13 A12 A13 B14 B15 A14 A15 B16 B17 A16 A17 B18 B19 A19 A18 RTN-1 IN-1 5 1 RTN-0 IN-0 14 14 W1 CR CL R4 I4 S4 O4 R3 I3 S3 O3 R2 I2 S2 O2 R1 I1 O1 S1 6 2 10 CABLE “B” Thermocouple 1756-IT6I CJC+ CJC- 1 N/A N/A N/A 1756-IF6I 1492-CONACAB010N3 c CABLE “A” 15 16 White/Red 18 19 Green 21 22 White/Black 24 25 White 12 RTN-3 10 IN-3/I 8 IN-3/V Orange f 11 RTN-2 9 IN-2/I 7 IN-2/V White/Orange Gray Black 6 4 2 RTN-1 IN-1/I IN-1/V 5 3 1 RTN-0 IN-0/I IN-0/V Conversion Module Installation and Application Considerations c Cables are available in 2.0m, or 5.0m d Terminals starting with A are the lower row of terminals, B terminals are the upper row. e Follow your PLC Analog User Manual for proper shield grounding instructions. f RTN terminals are internally connected on the 1756-IF6I. g Terminals w1, w2, w3, are spares used for field wire convenience. NOTE: This is only true for module RTP4. The Bul. 1492 cable does not connect to these terminals. 41171-085 Ver (00) Rockwell Automation Publication 1492-SG121E-EN-P - July 2016 131 Rockwell Automation Support Use the following resources to access support information. Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. www.rockwellautomation.com/knowledgebase Local Technical Support Phone Numbers Locate the phone number for your country. www.rockwellautomation.com/global/support/get-supportnow.page Direct Dial Codes Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer. www.rockwellautomation.com/global/support/direct-dial.page Literature Library Installation Instructions, Manuals, Brochures, and Technical Data. www.rockwellautomation.com/literature Product Compatibility and Download Center (PCDC) Get help determining how products interact, check features and capabilities, and find associated firmware. www.rockwellautomation.com/global/support/pcdc.page Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/ documents/du/ra-du002_-en-e.pdf. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainabilityethics/product-environmental-compliance.page. Allen-Bradley, ControlLogix, LISTEN. THINK. SOLVE, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication 1492-SG121E-EN-P - July 2016 Supersedes Publication 1492-SG121D-EN-P - October 2014 Copyright © 2016 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.