FM-A038□□-5CN
IR Receiver Modules for Remote Control Systems
Description
The FM-A038□□-5CN is a Bi-CMOS IC for use in infrared
remote control system.
Small-sized, light-weight, and low current consumption.
modules have been achieved by using resin mold.
The demodulated output signal can directly be decoded
by a microprocessor. The main benefit is the reliable
function even in disturbed ambient and the protection
against uncontrolled output pulses.
Features
 Photo detector and preamplifier in one package.
 Supply Voltage Range: 2.7V to 5.5V
 Internal filter for PCM frequency
 Insensitive to supply voltage ripple and noise
 Improved shielding against EMI (Built-in Shield Case)
 Improved immunity against ambient light
 Open collector output [ built-in Pull-up resistor(40K) ]
 Enhanced Immunity against all kinds of disturbance light
 Meet RoHS
Applications
Block Diagram
 TV, VCR, AUDIO
 Home Appliances
 Remote Control Equipment
Application Circuit (for power supply ripple suppression & ESD protection)
Component
Recommend
1) RS
Typ. 100Ω (47Ω~470Ω)
2) Cp1
Typ. 100uF (47uF~470uF)
3) Rp
Optional (10kΩ or more)
4) Cp2
Typ. 1nF (1nF~10nF)
5) D1~D3
Zener diode or TVS
(ESD Protection device)
Note:
A further influence to the IR receiver modules may come from a supply voltage which is not stable. Such a disturbed supply voltage can caused by
switching power supply. which is not filtered well or by other components in the circuit which produced spikes on the supply line.
This disturbed supply will reduce the sensitivity of receiver modules.
This application circuit will filter the disturbed supply voltage.
Page 1
光電企業有限公司
September 2012 Rev 1.0
www.opto-sensor.com.tw
FM-A038□□-5CN
Absolute Maximum Ratings
(Ta = 25℃)
Parameter
Symbol
Ratings
Unit
Supply Voltage
VCC
6.5
V
Supply Current
ICC
3.0
mA
Operating Temperature
Topr
-20 ~ +80
℃
Storage Temperature
Tstg
-30 ~ +85
℃
Soldering Temperature
Tsd
260℃, Max 5 sec
℃
Electro-optical Characteristics
(Ta = 25℃)
Parameter
Symbol
Min.
Typ.
Max.
Unit
Conditions
Supply Current
ICC
0.7
1
1.3
mA
No signal
Voh
Vcc-0.5
-
-
V
Vol
-
0.2
0.4
V
No external
pull-up resistor
(Isink<1mA)
Peak Wave Length
λp
-
940
-
nm
B.P.F. Center frequency
Fo
-
37.9
-
kHz
±0˚
20
-
-
m
±30˚
14
-
-
m
±45˚
10
-
-
m
400
600
800
us
Output Voltage
Arrival Distance
Output Pulse width
L
TWH / TWL
Fig 1,2,3
Burst Wave =600us
Period = 1.2ms
Note :
1) Arrival Distance Effected by Environment
2) While the device is operational across the temperature range, functionality will vary with temperature.
Specifications are stated only at 25°C unless otherwise noted.
3) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device.
These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated
under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Page 2
光電企業有限公司
September 2012 Rev 1.0
www.opto-sensor.com.tw
FM-A038□□-5CN
[ Fig.1 ] Data Signal diagram
t Pause
Data Word
enlarge
t Burst
Carrier Frequency : fo
t Gap
(Output pulse)
 t Gap : Signal gap time between two burst in pulses of carrier. Minimum Gap Time ≧ 300us
 t Burst : Length of a burst in pulses of the carrier frequency. Minimum Burst ≧ 300us
 t pause : Data pause between two data words. Minimum Data PauseTime ≧ 20ms
[ Fig.2 ] Transmitter
10K
PD
S/Transmitter
VCC
100uf
VOUT
10K
GND
30㎝
※ The specifications shall be satisfied under the following conditions. The standard transmitter
shall be specified of the burst wave form adjusted to VOUT 200mVp-p upon Po measuring
circuit Standard Transmitter
[ Fig.3 ] Test condition of arrival distance
Vout
Transmitter
osc
GND
Vcc
: Indicates horizontal and
vertical directions
[ Measurement condition for arrival distance ]
☞ Ambient light source : Detecting surface illumination shall be irradiate 200±50Lux
under ordinary white fluorescence lamp without high frequency lighting
Page 3
光電企業有限公司
September 2012 Rev 1.0
www.opto-sensor.com.tw
FM-A038□□-5CN
Electrical/Optical Characteristics
[ Fig.4 ] Supply Current vs. Voltage
[ Fig.5 ] Relative Spectral Sensitivity vs.
Wavelength
Supply Current(㎃)
2.5
2.0
1.5
1.0
0.5
0.0
2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
Supply Voltage(V)
[ Fig.6 ] Output Pulse Width vs. Distance
[ Fig.8 ] B.P.F Fc Curve
[ Fig.7 ] Directivity
ESD Test Results
Parameter
Page 4
Conditions
Specification
Results
Machine Model
C=200㎊,
R=0Ω
Min ±200V
>±200V
Human Body
Model
C=100㎊,
R=1.5㏀
Min ±2000V
>±2000V
光電企業有限公司
September 2012 Rev 1.0
www.opto-sensor.com.tw
FM-A038□□-5CN
FM-A038LM-5CN
FM-A038TM2-5CN
NOTE:
1.PIN CONFIG
①Vout
②GND
③Vcc
2.G.T±0.3
3.Internal metal Shielding
(UNIT: mm)
NOTE:
1.PIN CONFIG
①Vout
②GND
③Vcc
2.G.T±0.3
3.Internal metal Shielding
(UNIT: mm)
FM-A038TM2S2-5CN
NOTE:
1.PIN CONFIG
①Vout
②GND
③Vcc
2.G.T±0.3
3.Internal metal Shielding
(UNIT: mm)
Page 5
光電企業有限公司
September 2012 Rev 1.0
www.opto-sensor.com.tw