Survey
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
SENTRON 5SU9 Residual Current Circuit Breakers with Overcurrent Protection Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. siemens.com/answers 5SU9 Residual Current Circuit Breakers with Overcurrent Protection Residual Current Operated Circuit Breakers (RCBOs) are a combination of an RCCB and MCB in a compact design for personnel, fire and line protection. For personnel protection and fire protection, the residual current part of the type AC trips in the event of sinusoidal AC residual currents, type A also trips in the event of pulsating DC residual currents. RCBOs with a rated residual current of maximum 30 mA are used for personnel, material and fire protection, as well as for protection against direct contact. The MCB part of the 5SU9 RCBOs protects lines against overload and short circuits and is available in characteristics B, C and D. RCBOs comprise one part for fault-current detection and one part for overcurrent detection. They are equipped with a delayed overload/time-dependent thermal release (thermal bimetal) for low overcurrents and with an instantaneous electromagnetic release for higher overload and short-circuit currents. Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. Residual Current Circuit Breakers with Overcurrent Protection Portfolio Overview 5SU9, 5SV9 (electronic, voltage dependant) [1-4] Lines [5] Rated fault current (mA) 1MW 1MW 10 30 100 300 1+N 1+N 2P 1 5SU9 1 5SU9 5SU9 5SU9 5SU9 5SU9 5SU9 5SU9 5SU9 5SU9 5SU9 5SV9 5 5 5 5 6 6 6 6 0 0 0 4 0 6 5SU9 1 0 0 3 3 3 6 0 0 1 10 6 6 6 6 6 6 6 5 3 5SU9 5SU9 3P 4P 1+N 4,5 5 1 5SU9 Type AC 5 4 [8] RCD Type / MCB Characteristic - 2MW 5 3 3 3 3 3 3 3 5SU9 [7] Rated S.C. current Icn (kA) [6] No. of Poles 3 4 4 4 4 4 4 4 4 16 - B C 1 1 1 D [9-10] Suffix [11-12] Rated current Certifications Remarks Type A B C D 7 7 7 7 7 7 7 0 1 1 1 1 1 7 7 7 Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 8 2 KK VK KK KN KX KM KP KK KK KK KK KK KK KK KK KX NK 4 6 10 16 20 25 32 40 45 50 63 06 06 06 06 06 06 06 06 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 06 06 06 06 06 06 16 16 16 16 20 20 20 20 16 16 16 16 16 16 16 16 16 16 16 16 20 20 20 20 20 20 20 20 20 20 20 20 25 25 25 25 25 25 25 25 25 25 25 25 25 32 32 32 32 40 40 40 40 50 50 50 50 63 63 63 63 32 32 32 32 32 32 32 32 32 32 32 32 40 40 40 50 63 40 40 45 40 45 40 40 40 45 40 40 CE CCC RCM Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y N N N Y N N N N N N N N N s wi tched N N del a yed [K], s wi tched N N s wi tched N N OVP, s wi tched N N 110V, s wi tched N N s wi tched N Y Ta i l 300mm, s wi tched N Y s wi tched N N Ta i l 600mm, s ol i d N Y Ta i l 600mm, s ol i d N Y Ta i l 600mm, s ol i d N Y Ta i l 600mm, s ol i d N Y Ta i l 600mm, s ol i d N Y Ta i l 600mm, s ol i d N Y Ta i l 600mm, s ol i d N Y N T. 600mm 110/120V, 50/60Hz, s o. N s wi tched N, compa ct Y 5SU9 RCBOs Overview 5SU9 1+N solid N (5SU9.0.-.KK..) • • • • • • • • • • • • • • • Rated current: 6A ... 45A Rated switching capacity: 6kA , 10kA acc. IEC 60898-1 MCB tripping characteristics: B, C Rated voltage: AC 230V RCD Type Type AC, Type A I∆n: 10mA, 30mA, 100mA, 300mA Poles: 1P+N (solid N) Switching cycles: >10.000 (electrical & mechanical) Ambient temperature range: -25°C to +45°C Dimensions (HxWxD): 125mm x 18mm x 77mm Terminal conductor cross-sections: • Solid and stranded wire: 0,75 ... 35mm² • Finely stranded with end sleeve: 0,75 ... 25mm² • Outgoing: 0,75 ...16mm² N- and FE wire length: 600mm Environmental awareness: Compliance with RoHS Approvals & markings: CE Compliance with standards: IEC 61009-1, IEC 61009-2-2 Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5SU9 RCBOs Overview 5SU9 solid N special voltage (5SU9 304-7KX..) • • • • • • • • • • • • • • • Rated current: 6A ... 40A Rated switching capacity: 10kA acc. IEC 60898-1 MCB tripping characteristics: C Rated voltage: AC 110V / 120V; 50/60Hz RCD Type Type A I∆n: 30mA Poles: 1P+N (solid N) Switching cycles: >10.000 (electrical & mechanical) Ambient temperature range: -25°C to +45°C Dimensions (HxWxD): 125mm x 18mm x 77mm Terminal conductor cross-sections: • Solid and stranded wire: 0,75 ... 35mm² • Finely stranded with end sleeve: 0,75 ... 25mm² • Outgoing: 0,75 ...16mm² N- and FE wire length: 600mm Environmental awareness: Compliance with RoHS Approvals & markings: CE Compliance with standards: IEC 61009-1, IEC 61009-2-2 Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5SU9 RCBOs Overview 5SU9 1+N switched N (5SU9.5.-.K...) • • • • • • • • • • • Rated current: 6A ... 63A Rated switching capacity: 6kA , 10kA acc. IEC 60898-1 MCB tripping characteristics: C, D Rated voltage: AC 230V, AC 110V RCD Type Type AC, Type A I∆n: 10mA, 30mA Poles: 1P+N (switched N) Switching cycles: >10.000 (electrical & mechanical) Ambient temperature range: -25°C to +45°C Dimensions (HxWxD): 90mm x 36mm x 77mm Terminal conductor cross-sections: • Solid and stranded wire: 0,75 ... 35mm² • Finely stranded with end sleeve: 0,75 ... 25mm² • Environmental awareness: Compliance with RoHS • Approvals & markings: CE • Compliance with standards: IEC 61009-1, IEC 61009-2-2 Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5SU9 RCBOs Dimensions – Symbols 5SU9.0.-.KK.. Dimensions Symbols / Connection diagram and lettering Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5SU9 RCBOs Dimensions – Symbols 5SU9.5.-.K... Dimensions Symbols / Connection diagram and lettering Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5SU9 RCBOs Terminals and busbar compatibility • Terminal capacity • Solid and stranded wire: 0,75 ... 35mm² • Finely stranded with end sleeve: 0,75 ... 25mm² • Outgoing: 0,75 ...16mm² • Busbar compatibility • 5ST36 fixed length busbar system • 5ST37 busbar system suitable for cutting at desired lengths Example image depicting busbar capabilities, here shown at MCB 5ST3601 • By overlapping of fixed length busbars, quite boundless possiblilities for device combinations can be realized. • Overlapping of busbars can also be used for conductor-crosssection increase up to 32mm² (by use of adequate busbars from the 10mm² and 16mm² portfolio) Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5SU9 RCBOs Additional Components Busbar systems for 5SU9.0.-.KK.. (RCBO 1+N solid N) 5ST37 busbar system, single-phase, 10mm², for MCB 1P or 5SU9 RCBO 1+N solid N, can be cut, with end caps 10mm², for 12 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3730 (1 per pack) 16mm², for 12 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3700 (1per pack) 5ST360 busbar system, single-phase, for MCB 1P or 5SU9 RCBO 1+N solid N, can not be cut, fully insulated 10mm², for 2 MCBs or RCBOs 5SU9.0.-.KK.. : 10mm², for 6 MCBs or RCBOs 5SU9.0.-.KK.. : 10mm², for 12 RCBOs 5SU9.0.-.... : 5ST3600 (10 per pack) 5ST3601 (10 per pack) 5ST3602 (10 per pack) 16mm², for 2 MCBs or RCBOs 5SU9.0.-.KK.. : 16mm², for 6 MCBs or RCBOs 5SU9.0.-.KK.. : 16mm², for 12 MCBs or RCBOs 5SU9.0.-.KK.. : 5ST3630 (10 per pack) 5ST3631 (10 per pack) 5ST3632 (10 per pack) Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5SU9 RCBOs Additional Components Busbar systems for 5SU9.5.-.K... 5ST36 busbar system, four-phase, 10mm², for MCB 1P+N or 5SU9 RCBO 1+N switched N, can not be cut, fully insulated 10mm², for 6 MCBs 1P+N or RCBOs 5SU9.5.-.K... : 5ST3623 (10 per pack) 5ST36 busbar system, four-phase, 16mm², for MCB 1P+N or 5SU9 RCBO 1+N switched N, can not be cut, fully insulated 16mm², for 6 MCBs 1P+N or RCBOs 5SU9.5.-.K... : Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5ST3653 (10 per pack) 5SU9 RCBOs Additional Components Handle locking system for 5SU9 RCBOs Handle locking device, suitable for all padlocks from 3mm to 6mm: 5ST3801 5SU9 RCBOs are lockable in ON and OFF position Padlock for 5ST3806 handle locking device: Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. 5ST3802 Residual Current Circuit Breakers with Overcurrent Protection Tripping characteristic type "B" Tripping characteristic type "C" For universal use in socket outlet and lighting circuits For lamp circuits and motor circuits with high starting currents Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. Residual Current Circuit Breakers with Overcurrent Protection Tripping characteristic type "D" For electrical circuits with strong pulse-generating equipmentsuch as transformers or solenoid valves. Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten. Contact Page Peter Karl Product Manager IC LMV LP IEC P CP Siemensstrasse 10 93055 Regensburg Phone: +49 (941) 790-2066 Fax: +49 (941) 790-2227 Mobile: +49 (173) 7337767 E-mail: [email protected] Answers for infrastructure and cities. Frei verwendbar / © Siemens AG 2014. Alle Rechte vorbehalten.