Download S60DC40 Datasheet - Mouser Electronics

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts
no text concepts found
Transcript
Series S60DC40
Output to 40A, 600 Vdc
DC Solid-State Relay
FEATURES/BENEFITS
• Latest generation MOSFET technology
• Ultra low on-state resistance
• Innovative isolated driver ensures fast power transistor turn on and off and thus low
power transient
• Ultra low output leakage current
• Low control current consumption
• Triggered control input to avoid linear control risks
• Low conducted and radiated disturbances
Part Number
Description
MECHANICAL SPECIFICATION
S60DC40
40A, 600 Vdc Solid-State Relay
1.10 (28)
.089(22.8)
±.02 Ø0.5
0.89 (22.8)
Part Number Explanation
DC
40
2.29 (58.2)
Switch Type2
Line Voltage
Output Current – Amps
Series
1
NOTES
1) Line Voltage (peak): 60 = 600 Vdc
2) Switch Type: DC = DC
1+
2–
4–
3+
1.87 (47.6)
60
M5
1.7 (43.2)
S
1.10 (28)
ø0.19(ø
4.7)
Ø4.7
0.77
(19.6)
1.01 (25.8)
Max
Units
Control Range
4.5
32
Vdc
Input Current Range
25
42
mAdc
Typical Turn-On Voltage
4.3
Vdc
1
Vdc
Reverse Voltage
32
Vdc
Reverse Leakage Current
100
μA
CONTROL CHARACTERISTIC
Figure 1
BLOCK DIAGRAM
+3
CONTROL
Control Current (mAdc)
40
35
Driver
(OFF)
Single pulse
turn
LED ON & OFF
@25°C
circuit
1+
MOSFET
PHV
|Scst
25
M3
Tolerances: ±.001
Ø0.3
Dimensions in inches (mm)
Weight: 3.52 oz. (100g)
45
30
1.0 (25.4)
1.75 (44.5)
OUTPUT
Min
Must Turn-Off Voltage
0.29
(7.5)
INPUT (CONTROL) SPECIFICATIONS
0.20
(5.1)
ELECTRICAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
2–
–4
20
Figure 3
15
10
5
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32
Control Voltage (V)
Figure 2
© 2016 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
S60DC40 Page 1
S60DC40\012016\Q1
Series S60DC40
Output to 40A, 600 Vdc
DC Solid-State Relay
ELECTRICAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
DC Control
Power Supply
OUTPUT (LOAD) SPECIFICATIONS
Operating Range
DC Mains
Min
Max
0
350*
Vdc
600
Vpeak
Peak Voltage
Reverse Voltage (Internal Diode) 1.2
HIGH SIDE WIRING DIAGRAM
(Load Connected to “—”)
Units
20
A
Vc
(Red paths as
short as possible)
Ic
D2
2-
1800
C1
D1
or
Vt
3+
Maximum Single Pulse
Avalanche Energy
or
On-Off
Control
mJ
or
Maximum Repetitive Pulse
Avalanche Energy
1
mJ
Maximum Nominal Currents
(Resistive)
40
A
Non-Repetitive Peak
Overload Current
140
A
Leakage Current
250
μAdc
On-State Resistance
70
mΩ
Output Capacitance (Typical)
2.2
Load
Figure 4
LOW SIDE WIRING DIAGRAM
(Load Connected to “+”)
DC Control
Power Supply
nF
DC Mains
°C/W
8
°C/W
Ie
Ve
On-Off
Control
C1
2-
Heat Sink Thermal
Time Constant
Control Inputs/Power Outputs
Insulation Voltage
min
D1
or
D2
4
kV
or
Turn-On Time
10
μs
or
Turn-On Delay
600
μs
Turn-Off Time
10
μs
Turn-Off Delay
100
μs
On-Off Frequency
700
Hz
*Recommend 275 Vrms size 20 varistor as protection across the output.
Ic
Vt
1+
10
3+
Built-In Heat Sink Thermal
Resistance (Vertically Mounted)
0.4
Vc
(Red paths as
short as possible)
4-
Junction-Case
Thermal Resistance
S60DC40 Page 2
1+
4-
Maximum Repetitive
Avalanche Current
Ve
Ie
V
Load
Figure 5
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2016 TELEDYNE RELAYS
S60DC40\012016\Q1
Series S60DC40
Output to 40A, 600 Vdc
DC Solid-State Relay
GENERAL SPECIFICATIONS
(+25°C ambient temperature unless otherwise specified)
TIME DIAGRAMS
TURN-ON
ENVIRONMENTAL SPECIFICATIONS
Min
Vc
(control)
t
Vt
(switch)
t
tdon
ton
Units
Operating Temperature
–40
+90
°C
Storage Temperature
–55
+100
°C
Input-Output Isolation
4000
Vrms
Insulation Resistance
1
GΩ
Insulation Capacitance
8
pF
Junction Temperature
TURN-OFF
150
°C
CONNECTIONS
Power
Vc
(control)
Screwdriver
t
1.8 N.m
0.8 N.m
M5
M3
Insulated crimp terminals
(Round Tabs, Eyelet Type)
t
Control
Phillips NR2 Phillips NR1
Tightening Torque
Vt
(switch)
tdoff
Max
toff
MISCELLANEOUS
Figure 6
Display
Housing
ON RESISTANCE VS. TEMPERATURE
200
RDSon (mOhms)
Green LED (ON)
UL94V0
Mounting
2 screws (M4x12mm)
Noise Level
No audible noise
GENERAL
160
Standards
120
80
IEC60947-1
Protection Level
IP00
Protection Against Direct Touch
None
CE Marking
Yes
UL, cULUS & VDE Approvals
40
Pending
0
–50
0
50
100
Junction Temperature (°C)
Figure 7
© 2016 TELEDYNE RELAYS
E.M.C. EMISSION
150
Radiated & Conducted Disturbances
NFEN55011
(800) 284-7007 • www.teledynerelays.com
S60DC40 Page 3
S60DC40\012016\Q1
Series S60DC40
Output to 40A, 600 Vdc
DC Solid-State Relay
POWER DISSIPATION AND LOAD CURRENT LIMIT VS. TEMPERATURE
Please refer to the installation notice for
precautions about mounting the device on a heat sink.
45
284
1.2°C/W
1.1°C/W
0.9°C/W
0.75°C/W 0.55°C/W
0.3°C/W
0.2°C/W
0.1°C/W
40
224
35
172
30
126
25
87.5
20
56
15
31.5
10
14
5
Power Dissipation (W)
Load Current (Arms)
1.3°C/W
3.5
8°C/W
4°C/W
2.4°C/W
2.2°C/W
2.1°C/W
1.95°C/W
1.5°C/W
0
0
10
20
30
40
50
60
70
80
90
0
110
100
Ambient Temperature (°C)
Figure 8
PROTECTIVE COVER AVAILABLE
Add -14 to part number
Apeak
CURRENT OVERLOAD CHARACTERISTICS
Figure 9
NOTES
1. For additional/custom options, contact factory.
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
Non-repetitive peak overload
switching current vs. overvoltage
protection clamping voltage (D1)
Single pulse
F(on-off)=50Hz
F(on-off)=100Hz
F(on-off)=700Hz
0
100
200
300
400
500
600
Vtpk (V)
140
Non-repetitive
on-state (no switching)
max. peak current
vs.
overload pulse duration
120
APeak
100
80
60
40
20
0
0.1
1
10
100
1000
t(ms)
Figure 10
S60DC40 Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2016 TELEDYNE RELAYS
S60DC40\012016\Q1
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Teledyne Relays:
S60DC40
Related documents