Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Zero-configuration networking wikipedia , lookup
Computer network wikipedia , lookup
Airborne Networking wikipedia , lookup
TCP congestion control wikipedia , lookup
Recursive InterNetwork Architecture (RINA) wikipedia , lookup
Internet protocol suite wikipedia , lookup
Network tap wikipedia , lookup
CYGNUS 1110 Modbus Router and TCP/UDP/IP based Terminal Server with Built-in Network ports, RS232 ports and Ethernet ports monitoringervers\\\\\\\ontrol and Monitoring Applications FEATURES Single-box Modbus Router solution for allowing a number of user devices to communicate over an IP-based network in wide-area Access, Control and Monitoring applications that have RS232/RS485 and Ethernet based hosts and clients. A built-in IP routing function allows the CYGNUS 1110 units to either connect to an existing IP-based network, or be interconnected among themselves to form a new IP-based network. Two Network Ports with V.35 interface are provided. These can operate over leased lines at speeds up to 2 Mbps. Salient Features of Ethernet ports: Built-in 4-port managed switch for 10/100 Base-T devices Can connect to PCs, or TCP/IP clients or servers MAC address based port security to minimise chances of misuse Salient features of RS232 ports: Four RS232 compatible Terminal Ports (higher port models available), These ports can also be used by 2 wire RS485 devices using external Cygnus Converters. Provides different modes for handling RS232 port data. Modbus TCP/IP and Serial RTU/ASCII based packetization for handling terminal port data: This is suitable for control and monitoring of multiple Modbus Serial slave devices connected to one or more RS232 ports. It also supports conversion from one form of Modbus like Modbus TCP to Modbus Serial and vice-versa. UDP based packetization for handling raw RS232 port data, with versatile data forwarding methods to replace party line master-slave network formed out of multidrop analog modems. TCP based packetization for handling RS232 port data for an error-free, in-sequence delivery of data between two RS232 ports, or between an RS232 port and a remote TCP/IP host. The unit can also be used as a standalone Terminal Server with TCP/UDP-over-IP based data forwarding between RS232 user devices and an Ethernet host Menu-based supervisor, with commands for configuration, diagnostics, statistics and status reports are provided. 1500 VAC isolation option on RS232 ports A separate RS232 compatible console port is provided for supervisory configuration and monitoring. In addition, the unit can also be configured and monitored from a central NMS using Telnet. Support is provided to generate SNMP “Traps” on user-selectable events Field upgradable firmware External converters available from CYGNUS for RS232 to 2-wire RS485, 4-wire RS422 or 20mA current loop interface. MOD B U S SER IA L MA STER R S 485 R S 232 C YGN U S 1110 N P /V.35 N P /V.35 N P/ NP/ V.35 V.35 L eased Lines N P /V.35 R S 232 R S 232 891 MOD B U S S E R IAL R T U IP N etw ork M OD B U S T C P S L AV E E thernet E thernet N P /V.35 C YGN U S 1110 C Y GN U S R S 2 3 2 -to -R S 4 8 5 C o n ve rte r E thernet N P/ V.35 NP/ V.35 MOD B U S TC P MA STER MOD B U S TC P MA STER 891 CYGNUS 1110 E thernet CYGNUS 1110 C Y GN U S R S 2 3 2 -to -R S 4 8 5 C o n verte r M OD B U S E T H TC P S LAV E R S 48 5 Bu s M OD B U S MOD B U S S E R IAL R TU S E R IAL R T U An stan d alo n e IP b ased N etw o rk o f C Y GN US 1110 th at fo rm s a M o d b u s m o n ito rin g n etw o rk w ith o n e M o d b u s T C P M aster an d several Mo d b u s RT U slaves o n R S 485 b u s o r R S 232. A Mo d b u s S erial M aster is also sh o w n . C YGN U S 1110 C YGN U S R S 23 2 -to -R S4 8 5 C o n ve rte r R S 232 891 R S4 8 5 Bu s M OD B U S M OD B U S S E R IAL R T U S E R IAL R TU M OD B U S S E R IAL R T U A C Y GN U S 1110 M o d b u s R o u ter w ith several Mo d b u s R T U slave d evices co n n ected to an existin g IP R o u ter n etw o rk u sin g E th ern et p o rt. The CYGNUS 1110 Modbus Router is ideal for commissioning an independent IP-based wide area network, or for extending an existing IP-based network to carry out Access, Control and Monitoring of slave devices and hosts. provides a configurable list of Modbus slave IP address and port number. Modbus Router will enhance system maintenance capabilities. It has port specific diagnostics that display status, message response timing, timeout and error counts and message statistics. For connection to the IP network through leased lines, the CYGNUS 1110 has two V.35 compatible WAN ports. These ports can be connected to WAN ports of existing routers in the user’s IP network using leased lines and external modems or can form a network amongst themselves. Configurations such as redundant ring can be formed out of cascading units interconnected through their V.35 ports. . The CYGNUS 1110 can also be connected to an existing TCP/IP network using 10/100 Base-T Ethernet ports through which it can connect to devices such as PCs, Ethernet based RTUs, Modbus/TCP Servers and Masters etc. A Modbus Serial Master connected to one terminal port of the CYGNUS 1110 is defined to send data to other Modbus TCP Slaves or Modbus Router devices connected in an IP based network. By this the Modbus Serial Master can poll its slave devices which are distributed across the IP network. On the other hand multiple Modbus Serial Slaves connected to terminal ports using an RS232 interface or RS485 interface through external RS232 to RS485 adapter (available from CYGNUS) are mapped to a well know socket of the CYGNUS 1110 to which remote Modbus Master (Serial or TCP) can send its data. The responses from the Modbus Serial slaves are collected and sent to the remote Modbus Master using Modbus (TCP) response packets. Asynchronous RS232 ports of the CYGNUS 1110 can be used by a variety of serial user devices such as RTUs, Dataloggers, start-stop character based dumb terminals and PC’s COM ports. The functionality offered by the unit to RS232 devices is what makes it versatile. It provides Modbus TCP, UDP or raw TCP modes for encapsulating RS232 port traffic for sending to or receiving from a destination host over the IP network. The host system (master) itself can be configured for connection to a RS232 port of a CYGNUS 1110 unit in the network. If UDP mode of RS232 port traffic handling is selected, a network of CYGNUS 1110 can transparently replace a one-master multiple-slave mutidrop party line network of devices which uses analog modems. A UDP packets formed out of Host system’s poll on its RS232 port is sent almost simultaneously to multiple slaves which are connected to RS232 ports of different CYGNUS 1110 units. The response, which is given only by the addressed RTU/Datalogger is received by its connected CYGNUS 1110 unit and forwarded to the Master’s RS232 port in a UDP packet, thereby completing the poll/response cycle. The unit has ability to connect a remote Modbus Master to multiple Modbus Slave devices that can connect to different RS232 ports of the unit. It supports conversion from one form of Modbus, such as Modbus TCP to Modbus RTU or Modbus ASCII. One Terminal port of CYGNUS 1110 can be configured to a Modbus Serial Master and remaining all ports can be configured as Modbus Serial Slaves. The CYGNUS 1110 If guaranteed delivery of user data from devices such as RS232 transaction processing terminals, TCP mode should be used. This mode provides error-free in-sequence character stream transfer between two RS232 ports of this units in the network, or between a RS232 port and a remote host with Ethernet interface. SPECIFICATIONS Ethernet Ports (EPs) No. of ports Compliance/ features Connector Terminal Ports (TPs) No. of ports Compliance Connector Data Forwarding (for UDP encapsulation) Protocol support WAN Ports No. of WAN ports Compliance Connector Function Four 10/100 Base-T, IEEE 802.3u, Auto negotiation, Auto MDIX RJ 45 socket Four (higher ports model is available) Asynchronous RS232 with TxD, RxD, DTR, DSR, RTS, CTS, DCD signals. Speed up to 57,600 bps. Note: If the optional 1500 VAC isolation is provided on RS232 ports, only Tx, Rx and Ground signals are available RJ 45 socket Programmable Idle timeout, one character or two character sequence, fixed timeout Modbus serial RTU, Modbus ASCII (Master and Slave) Speed Two ITU-T V.35 synchronous ports 25 pin D type Male with adapter cable for V.35 connection. Up to 2 Mbps Console Port Character format Compliance Connector 9600 bps, 8 bits, no parity Asynchronous RS232 RJ45 socket Giving commands for configuring, monitoring and diagnosing the unit Management and Control of the Unit Supervisory access Menu based, password protected supervisory function accessed via Console Port or via Telnet over the network Supervisory Enable/disable ports, select port parameters commands for EPs (flow control, speed, duplex), name port, view statistics Supervisory Enable/disable ports, select port parameters commands for TPs (speed, parity, flow control, etc.), view statistics Protocol Support TCP/IP protocols TCP, IP, PPP, UDP, ICMP, IGMP, ARP, DHCP, BOOTP Routing protocols Static Routing, RIP V1, RIP V2, OSPF Application protocols Modbus TCP Indicators For each EP Link, Activity For each TP Transmit, Receive For WAN Ports Transmit, Receive, Link General Power Operating environment Option for AC (230 V, 50 Hz, single phase) or DC (-48 V) power supply 0-50 deg C, 5-95% RH (non condensing) Note: Specifications are subject to change without notice Ref.: 140530 CYGNUS MICROSYSTEMS (P) LIMITED 93, IDA Phase II, Cherlapally, Hyderabad 500 051, India Tel: +91 (40) 2726 1326 Fax: +91 (40) 2726 1167 URL: www.cygnusmicro.com e-mail: [email protected] ISO 9001:2008 Registered