MDW1210W
Dome Mount
Installation Manual
HDMU000958 - May 2004 - Rev. A
ISSUE
DATE
A
May 2004
Rev. A
REVISIONS
Initial Release
ii
HDMU000958
5/14/04
EXPLANATION OF GRAPHICAL SYMBOLS
The lightning flash with arrowhead symbol within an equilateral triangle is intended to
alert the user to the presence of uninsulated "dangerous voltage" within the product's
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instruction in the literature
accompanying the product.
Rev. A
iii
HDMU000958
5/14/04
TABLE OF CONTENTS
1.0
PRODUCT DESCRIPTION ............................................................................................................ 1
2.0
INSTALLING THE MOUNT............................................................................................................ 1
LIST OF FIGURES
Figure 1. MDW1210W Outdoor Dome Wall Mount (519380-2420).......................................................... 1
Figure 2. KD6 Series Weather Dome Wiring ............................................................................................ 2
Rev. A
iv
HDMU000958
5/14/04
1.0
PRODUCT DESCRIPTION
The MDW1210W wall mount is for mounting 9" outdoor KD6 domes. This mount is for
use only with later revisions of the weather and pressurized domes with extended pigtail
cable lengths.
The MDW1210W is compatible with the CMA18W corner mount adapter (used for
installing the mount on the corner of a building) and the PMA18W pole mount adapter
(for pole mount applications).
The outdoor wall mount must be installed by qualified service and installation personnel.
The installation must be in accordance with all local and national electrical and
mechanical codes.
2.0
INSTALLING THE MOUNT
1. Select the location of the mount and ensure that a 110-120V ac, 60 Hz or 220-240 V
ac, 50/60 Hz to 24V ac power source is available in a dry protected environment.
Refer to Figure 1-2 for the amperage required for your specific weather dome and for
the maximum wiring distances to maintain the required voltage for your specific
weather dome.
CAUTION: This mount must be tied to a true earth
ground. If the structure is not at ground potential, an
electrical connection must be made from the mounting
flanges to earth ground.
CAUTION: Surge protection on the data, video, and
power lines is recommended. Honeywell will not
warranty any equipment damaged by lightning induced
electrical surges if surge protection is not provided. A
power supply with surge protection is available to protect
the domes. This power supply is available with an output
for a 115V or 24V heater/blower. Installation procedures
for this power supply are provided in Manual Number
517899-1960.
2. Mount the neoprene gasket and wall mount to the wall using the appropriate
hardware for the surface. The hardware is supplied by the installer. The mount
must be able to support four (4) times the maximum load specified. Refer to the
installation drawings for maximum load.
NOTE: A 1-inch hole is required in the wall or mounting surface to accommodate the
field run cabling.
Rev. A
1
HDMU000958
5/14/04
2.0
INSTALLING THE MOUNT, CONTINUED
3. Secure a safety cable to a building support structure. The safety cable and
hardware required to secure it are the responsibility of the installer. Ultrak
recommends using 3/32" plastic coated aircraft cable, Diamond part number
849518-0311. If a looping sleeve is required, use Ultrak part number 849511-0057.
The tool required to crimp the looping sleeve is part number 941508-0049.
4. Route the field wiring (data, video, scan power, heater power and alarms) through
the wall or mounting surface, into the mount, and out the access hole on the bottom
side of the mount. Remove the access hole cover plate by removing the two #8-32
screws attaching it to the mount. Refer to Figure 2 for HD6 Series Wiring
Information.
Route the safety cable through the wall or mounting surface, into the mount and out
the threaded dome mounting hole at the end of the mount.
5. Seal all joints and screws in the outdoor mount. Use Dow 3145 RTV for screws,
bolts, joints, and all mounting surfaces. Use Teflon tape for screw-together joints.
CAUTION: . All JOINTS, BOLTS, AND SCREWS IN THE
WALL MOUNT MUST BE SEALED TO PREVENT WATER
(MOISTURE) FROM ENTERING DOME.
6. Refer to the weather dome instructions for mounting the dome on the mount.
Rev. A
2
HDMU000958
5/14/04
Figure 1. MDW1210W Outdoor Dome Wall Mount (519380-2420)
Rev. A
1
HDMU000958
5/14/04
Figure 2. KD6 Series Weather Dome Wiring
Rev. A
2
HDMU000958
5/14/04
NOTES:
Rev. A
3
HDMU000958
5/14/04
Video Systems
www.honeywellvideo.com
1-800-796-CCTV
© 2004 Honeywell International Inc.
All rights reserved. No part of this publication may be reproduced by any means without written
permission from Honeywell Video Systems. The information in this publication is believed to be accurate
in all respects. However, Honeywell Video Systems cannot assume responsibility for any consequences
resulting from the use thereof. The information contained herein is subject to change without notice.
Revisions or new editions to this publication may be issued to incorporate such changes.
Rev. A
4
HDMU000958
5/14/04