Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
CDN Resource Laboratories Ltd. #2, 20148 - 102nd Avenue, Langley, B.C., Canada, V1M 4B4, Ph: 604-882-8422 Fax: 604-882-8466 (www.cdnlabs.com) GOLD ORE REFERENCE STANDARD: CDN-GS-10E Recommended value and the "Between Laboratory" two standard deviations Gold 9.59 g/t ± 0.53 g/t Certified value 30g FA / Gravimetric PREPARED BY: CDN Resource Laboratories Ltd. CERTIFIED BY: Duncan Sanderson, B.Sc., Licensed Assayer of British Columbia INDEPENDENT GEOCHEMIST: Dr. Barry Smee., Ph.D., P. Geo. DATE OF CERTIFICATION: October 1, 2015 ORIGIN OF REFERENCE MATERIAL: Standard CDN-GS-10E was prepared by blending 430 kg of gold ore with 370 kg of granite. METHOD OF PREPARATION: Reject ore material was dried, crushed, pulverized and then passed through a 270 mesh screen. The +270 material was discarded. The -270 material was mixed in a double-cone blender for 5 days. Splits were taken and sent to 15 commercial laboratories for round robin assaying. Round robin results are displayed below: Lab 1 Lab 2 Lab 3 Lab 4 Lab 5 Lab 6 Lab 7 Lab 8 Lab 9 Lab 10 Lab 11 Lab 12 Lab 13 Lab 14 Lab 15 SAMPLE Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t Au g/t GS-10E-1 9.62 10.30 9.59 9.76 9.88 9.22 9.33 10.25 9.54 9.82 10.09 9.15 9.93 9.24 9.58 GS-10E-2 9.29 10.10 10.00 9.69 9.52 9.28 9.84 9.88 9.50 9.75 10.03 9.58 9.33 9.29 9.40 GS-10E-3 9.42 9.97 9.67 9.06 9.34 9.49 9.81 9.86 9.89 9.71 10.05 9.26 9.57 9.82 9.53 GS-10E-4 9.14 9.66 9.87 9.98 9.37 9.24 9.43 10.40 9.56 9.70 9.76 9.10 9.27 9.84 9.49 GS-10E-5 9.58 9.67 9.43 9.38 9.98 9.23 9.50 9.96 9.92 9.66 9.69 9.26 9.27 9.31 9.72 GS-10E-6 8.81 9.76 9.53 9.47 9.32 9.80 9.70 9.71 9.46 9.71 9.01 9.15 9.77 9.35 9.42 GS-10E-7 9.45 10.00 9.53 9.30 9.40 9.68 10.00 9.49 9.76 9.74 9.81 9.59 10.00 8.87 9.43 GS-10E-8 9.42 9.81 10.10 9.09 9.60 9.83 9.50 9.51 9.68 9.74 9.99 9.19 9.47 9.52 9.64 GS-10E-9 9.75 10.00 9.47 9.59 9.79 9.37 10.10 9.56 9.40 9.82 9.94 9.28 9.63 10.05 9.61 GS-10E-10 10.29 9.66 9.55 9.12 9.52 9.48 9.46 9.91 9.55 9.66 9.13 9.49 9.33 9.41 9.46 Mean Std. Dev'n %RSD 9.48 9.89 9.67 9.44 9.57 9.46 9.67 9.85 9.63 9.73 9.75 9.30 9.56 9.47 9.53 0.3898 0.2161 0.2336 0.3113 0.2364 0.2361 0.2621 0.3033 0.1792 0.0543 0.3825 0.1812 0.2717 0.3479 0.1067 4.11 2.18 2.42 3.30 2.47 2.49 2.71 3.08 1.86 0.56 3.92 1.95 2.84 3.67 1.12 APPROXIMATE CHEMICAL COMPOSITION (by whole rock analysis): SiO2 Al2O3 Fe2O3 CaO MnO Total S Percent 61.8 14.0 7.2 4.2 <0.1 2.3 Na2O MgO K2O TiO2 LOI Total C Percent 1.6 3.7 2.9 0.4 2.5 <0.1 GOLD ORE REFERENCE STANDARD: CDN-GS-10E Statistical Procedures: The final limits were calculated after first determining if all data was compatible within a spread normally expected for similar analytical methods done by reputable laboratories. Data from any one laboratory was removed from further calculations when the mean of all analyses from that laboratory failed a t test of the global means of the other laboratories. The mean and standard deviation were calculated using all remaining data. Any analysis that fell outside of the mean ±2 standard deviations was removed from the ensuing data base. The mean and standard deviations were again calculated using the remaining data. This method is different from that used by Government agencies in that the actual “between-laboratory” standard deviation is used in the calculations. This produces upper and lower limits that reflect actual individual analyses rather than a grouped set of analyses. The limits can therefore be used to monitor accuracy from individual analyses, unlike the Confidence Limits published on other standards. Participating Laboratories: (not in same order as table of assays) Bureau Veritas, Vancouver, British Columbia, Canada Accurassay, Thunder Bay, Ontario, Canada Activation Laboratories, Ancaster, Ontario, Canada Activation Laboratories, Thunder Bay, Ontario, Canada American Assay Laboratories, Nevada, United States ALS Canada, North Vancouver, British Columbia, Canada ALS Reno, Nevada, United States Argetest, Ankara, Turkey Certimin, Lima, Peru Met-Solve Analytical, Langley, British Columbia, Canada ALS Loughrea (OMAC), Ireland Skyline Assayers & Laboratories Ltd, Arizona, United States SGS, Vancouver, British Columbia, Canada SGS, Lima, Peru TSL Laboratories Ltd., Saskatoon, Saskatchewan, Canada Legal Notice: This certificate and the reference material described in it have been prepared with due care and attention. However CDN Resource Laboratories Ltd. nor Barry Smee accept any liability for any decisions or actions taken following the use of the reference material. Our liability is limited solely to the cost of the reference material. Certified by _____________________________________ Duncan Sanderson, Certified Assayer of B.C. Geochemist _____________________________________ Dr. Barry Smee, Ph.D., P. Geo.