Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Magellan QT ® Quick Install Thermoplastic Exit Sign housing. Housing design simplifies installation, and does not require hard wire terminations inside of the exit housing. MQTELNCWSRSC The installation process enables the installer to easily make all wiring connections in the junction box, while all mechanical connections between the exit housing and canopy are made tool free. The standard product can be top, end, or back-to-wall mounted, simply by selecting the access port located on the top, end or back of the exit enclosure. All access ports incorporate mechanical connections for direct installation to standard junction boxes via the mounting canopy. Illumination Illumination of the exit stencil face is accomplished with long lasting, high output Light Emitting Diodes (LEDs). Hot spots and striations are eliminated by the internal “light chamber” especially designed around the high performance LED array. MQTDL12WSRSC General Description The Magellan QT Thermoplastic LED exit sign combines an appealing design, high impact thermoplastic and high performance electronics to ensure reliability. Softly rounded corners and the universal mounting configuration allow the product to blend nicely with all modern interiors. The Magellan QT has been engineered to ensure ease of installation, as well as provide years of low cost, efficient service. The simplified installation process makes the Magellan QT LED exit both a preferred specification product and electrical contractor favorite. Housing Impact resistant, UL 94 V-0, 5 VA thermoplastic housing with NFPA-type field selectable chevrons. Chevrons can be installed/removed from outside the exit housing. White and black housing finish is available. Installation The canopy installs to a standard junction box by using screws supplied with the junction box, or by utilizing “no tools” connectors supplied with the Magellan QT luminaire. Electrical power supply connections are made using the modular plug assemblies supplied with the product, and are routed though the center of the canopy for connection to the mating plug assembly furnished with the exit housing. The Magellan QT exit housing will mechanically “snapfit” to the canopy. Once connected the Magellan QT exit will route AC normal utility power and begin charging the battery when it recognizes AC utility power is available. Electronics AC Only and Emergency Operation Units Dual voltage 120/277 VAC input with surge protection is standard. Self-Powered Units All components are located within exit housing. An indicator light is located on the bottom of the housing to signify that AC utility is present. UL damp location listing is available. (DL option on select models) AC lockout prevents battery drain prior to the initial energizing of utility power. Mechanical and electrical connections allow installation to a standard ceiling or wall mounted junction box without the need to make hard wire terminations within the exit The low voltage disconnect (LVD) feature will disconnect the battery prior to an unacceptable deep discharge, but not before the required 90 minute emergency operation. HL-1908 Rev. 5/2/13 The brownout protection circuitry will automatically switch the unit into the emergency mode if the utility voltage sags below 20% of nominal. Exits Battery charging circuitry is entirely solid-state, and of a constant current design. Battery recharge time after a complete discharge is less than the required UL 924 standard. Solid-state circuitry causes an instantaneous transfer to battery power if either the loss of AC utility, or a brownout condition is detected. When line voltage is present and stabilized, the transfer circuitry switches back to normal operation and begins recharging the battery. The transfer circuitry can be tested via a momentary test switch located on the bottom of the housing. Battery A maintenance free, sealed nickel cadmium battery is standard. Construction is of the sintered plate design and the battery assembly is equipped with a quick connect plug assembly for easy installation. Standard sustained emergency operation is for 90 minutes with the illumination source providing full light output. Batteries can be serviced by easily removing the exit stencil front for battery inspection and/or replacement. The suggested operating temperature range is 20°F (-7°C) to 95°F (35°C). Typical life of lead calcium battery is up to 5 years; for nickel cadmium battery up to 10 years. Electrical Specifications AC Only Operation Input Power Requirements at 120 VAC Red – .89 watts Green – 2.17 watts Self-Powered Operation Input Power Requirements at 120 VAC Red – 3.62 watts Green – 2.79 watts Listings •UL 924 listed • UL Damp Location listing optional • NFPA 101, NEC, BOCA, OSHA and IBC illumination standards Warranty 3-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Actual performance may differ as a result of end-user environment and application. Note: Specifications are subject to change without notice. Magellan QT ® ® Quick Install Thermoplastic Exit Sign Dimensions Suggested Specification Circuitry shall include both a “push-to-test” switch and “utility power present” indicator LED. Furnish and install Holophane’s LED exit sign model _______________________. The exit shall be constructed to meet Underwriter’s Laboratories, Inc. Standard #924 and the National Electrical Code (NEC). Battery (Self-powered operation only) 15.5” (393.7mm) 13.75” (349.2mm) 9.5” (241.3mm) The battery shall be maintenance free, sealed nickel cadmium utilizing sintered plate construction and polypropylene separators for trouble-free operation in ambient temperatures up to 95ºF (35ºC). 15.0” (381mm) Installation and Operation 1.66” (4.2mm) 8.05” (204.47mm) 7.3” (185.4mm) 5.05” (128.2mm) 15.5” (393.7mm) 13.75” (349.2mm) 9.5” (241.3mm) 15.0” (381mm) 1.66” (4.2mm) 8.05” (204.47mm) 1.55” (39.3mm) 5.05” (128.2mm) 13.75” (349.2mm) Illumination The Magellan QT exit sign shall incorporate high intensity LEDs. The LEDs shall be designed so that the unlikely failure of the LED will not affect the integrity of the total sign in the emergency mode. The Magellan QT exit equipped with red LEDs shall consume .89 watts (120 VAC) or 3.62 watts (120 VAC Self-powered). If equipped with green LEDs, it shall consume 2.17 watts (120 VAC) or 2.79 watts (Self-powered). Housing The Magellan QT LED exit housing shall be constructed of impact resistant, UL 94 V-0, 5 VA thermoplastic, with NFPAtype field selectable chevrons. The chevrons can be configured for direction in the field without removal of the exit stencil. The housing, stencil and canopy finish shall be either white or black. Mechanical connection of the exit housing to the junction box shall be accomplished without any requirement to open the exit housing for wiring or mechanical terminations. Charger (Self-powered only) 1.66” (4.2mm) 7.3” (185.4mm) Exit shall be easily field connected to a 120 or 277 VAC, 60 1.66” hertz, unswitched power source. Installation must comply (4.2mm) with the NEC as well as other applicable codes. Product installation should not require entry inside of the exit housing .60” (15.2mm) wiring connections in the field. Mechanical to make or arrange connections to standard junction boxes shall be accomplished 5.05” (128.2mm) by utilizing the access ports and canopy connector supplied with the product. (Self-Powered Only) - Upon utility power failure or brownout, the unit shall automatically transfer to battery power and maintain the required illumination level for a minimum period of 90 minutes. Upon restoration of utility power, the charger shall restore the battery to full charge within UL 924 requirements following a rated discharge of not more than 90 minutes. 13.75” (349.2mm) 1.55” (39.3mm) Product shall utilize a constant current charging system which will maintain the battery at full capacity without the need of periodic exercising or equalization. The following features shall be standard: low voltage disconnect (LVD), brownout protection and AC lockout. .60” (15.2mm) 5.05” (128.2mm) Exits Ordering Data MQTE Series MQTE Magellan QT thermoplastic exit MQTD Magellan QT thermoplastic double head exit with 2 T6, 5.4 watt tungsten lamps L How to construct a catalog number Example: MQTE L NC W SR S C NK NC W SR S C C1 Frame Number of Faces Letter/Face Color Mounting S Single face C Canopy mount W White thermoplastic SGThermoplastic D Double face B Black thermoplastic stencil face, green letU1 Universal face ter 1 1 door kit, 2 stencil SRThermoplastic Operation faces, 2 lenses stencil face, red letter 1 Options (Factory installed) AM AC only multi-voltage 120/277 VAC input C1 120VAC two circuit wiring (Available with “AM” operation only) 1 NC Nickel cadmium emergency 120/277 VAC input C2 277 VAC, two circuit wiring (Available with “AM” operation only) 122 Lead calcium emergency 12 watt head capacity 120/277VAC input BFBuzzer/flasher (Not available with “AM” or “NK”) 2 BZ Buzzer (Not available with “AM” or “NK”) 14N Nickel cadmium emergency 14 watt head capacity 120/277VAC input DL Damp location (Not available with options NK, ST, or MQTDL12, MQTDL18) 182 Lead calcium emergency 18 watt head capacity 120/277VAC input F Fire alarm interface (Not available with “AM” or “NK”) 18N2 Nickel cadmium emergency 18 watt head capacity 120/277VAC input FL Flasher (Not available with “AM” or “NK”) 252 Lead calcium emergency 25 watt head capacity 120/277VAC input VRS Vandal resistant lens (Available with MQTD only) order 1 per face Lamp Type L LED direct 1 “MQTE” only 2 “MQTD” only X1 X2 X3 LL 1 200 volt 50/60 Hz transformer 220 volt 50/60 Hz transformer 240 volt 50/60 Hz transformer Matching low level remote exit, thermoplastic frame (“MQTD” 18, 18N or 25 operation only, not available with NK) available with NK) LP 1 EX NK TP T7 T9 H7 H12 ST Matching low level remote exit, aluminum frame (“MQTD” 18, 18N or 25 operation only, not Special input transformer (specify voltages and frequency). Consult factory Self diagnostics (not available with “AM” operation) Tamperproof screws (includes tamperproof bit) Tungsten 7 watt, optional heads for MQDT only Tungsten 9 watt, optional heads for MQDT only Halogen 7 watt, optional heads for MQDT only Halogen 12 watt, optional heads for MQDT only Quick check self diagnostics with 15 minute time delay 1 “LP” and “LL” options reflect price of remote exit and wiring harness only to be added to price of master exit 2 Available on 25 watt lead calcium and nickel cadmium batteries 3 Available with AM operation only Accessories (Ships separately) Available with MQTE series only HPSPKIT12WH 1,2 Unison exit pendant kit, 12 inch, white finish HPSPKIT12BK 1,2 Unison exit pendant kit, 12 inch, black finish HPT15TPTOOL Tamper-proof screwdriver HPWG4 Wire guard for exit wall mounting HPWG10 Wire guard for exit end mounting PVS Polycarbonate vandal shield (“MQTE” only) Acuity Brands Lighting, Inc. Holophane Headquarters, 3825 Columbus Road, Granville, OH 43023 Acuity Brands Lighting Canada, Inc., 35B Minthorn Blvd., Markham, ON., L3T 7N5 Holophane Europe Limited, Bond Ave., Milton Keynes MK1 1JG, England Holophane, S.A. de C.V., Km. 31 Carretera Mexico-Cuautitlan 54900 Tultitlan Edo. De Mexico 1 Consult factory for special pendant lengths 2 Not available with NK option Contact your local Holophane factory sales representative for application assistance, and computer-aided design and cost studies. For information on other Holophane products and systems, call the Inside Sales Service Department at 740-345-9631. In Canada call 905-886-8967. HL-1908 Rev. 5/2/13 ©2012-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Visit our web site at www.holophane.com Luminaires may utilize fluorescent or high intensity discharge sources that contain small amounts of mercury. New disposal labeling for these lamps includes the mercury identifier shown on the left to indicate that the lamp contains mercury and should be disposed of in accordance with local requirements. Information sources regarding lamp recycling and disposal are included on the packaging of most mercury-containing lamps and also can be located at www.lamprecycle.org.