Download MCL2 UK - Fil Control

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Flip-flop (electronics) wikipedia , lookup

Analog-to-digital converter wikipedia , lookup

Power MOSFET wikipedia , lookup

Lego Mindstorms wikipedia , lookup

Amplifier wikipedia , lookup

Surge protector wikipedia , lookup

Radio transmitter design wikipedia , lookup

Integrating ADC wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Immunity-aware programming wikipedia , lookup

CMOS wikipedia , lookup

Wilson current mirror wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Voltage regulator wikipedia , lookup

Operational amplifier wikipedia , lookup

Schmitt trigger wikipedia , lookup

Current mirror wikipedia , lookup

Power electronics wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Rectiverter wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
FIL CONTROL REV : 5
FIL CONTROL
Application
The MCL2 is a yarn break capacitive sensor useful for assembling, and winding applications.
MAIN FUNCTION: To control the linear motion of two textile yarns when assembling.
When a yarn breaks or stops, the MCL2 will inform the user (flashing LED) that a position is defective. It
can also activate a yarn cutter or stop the position giving a LOW signal to an automate.
Any kind of material able to keep electrostatic charge can be checked by the MCL2.
PRINCIPLE: The MCL2 probe will check the tension variations produced by the electrical charges into the
yarn in motion. The MCL2 is insensitive to dust and vibrations.
ELECTRICAL PROTECTION: The MCL2 is protected against reversed polarity and high level overload on
output. It shows a very high level of EMC, electromagnetic compatibility : >4 kV.
Characteristics :
Power supply : 18 to 30 V DC
NPN output
Inhibition switch
External programming or inhibition input
1 or 2 thread supervising mode can be selected
Visual alarm (red LED)
Connection cable, Lumberg 2,5 MSFW 5 connector or any kind
of connector on request
Sensor sensibility can be adapted to operator’s requirement
These characteristics are adapted to operator’s requirements. (Referenced to the
codification board)
Dimensions (mm)
One of these guides can be adapted on the MCL2 :
CA9-TD011 (Aluminium oxide)
CA9-TD016 (Titanium oxide)
CA9-TD003 (Aluminium oxide)
CA9-TD013 (Zirconium aluminium)
CA9-TD014 (Zirconium aluminium)
CA9-TD015 (Aluminium oxide)
Fil Control is not liable for any errors or omissions this document may be contain, or for any damage resulting from this application or of the information
herein. Fil Control reserves the right to change the specifications of its products at any time without notice.
FIL CONTROL REV : 5
FIL CONTROL
Characteristic codification
MCL2-
X
X
X
X
X
Inhibition / Pilot light / Programming
External input
Push button
LED
Without
With
Without
With
Without
With
Without
With
Without
Without
With
With
Without
Without
With
With
Without
Without
Without
Without
With
With
With
With
1
2
3
4
5
6
7
8
Number of supervised thread
auto-set at start-up
Number of supervised thread
set by remote control input
Guides
Without guide
CA9-TD011
CA9-TD003
CA9-TD013
CA9-TD014
CA9-TD015
CA9-TD016
0
1
2
3
4
5
6
Connections
By cable
By connector
1
2
Response time (ms)
100
200
600
900
3
4
5
6
Output
NPN Normally open (NO)
NPN Normally close (NC)
1
3
Example
MCL2-84261
-
8 : with push-button, LED and external inhibition or programming input
4 : with guide CA9-TD014
2 : with Lumberg 2,5 MSFW 5 connector
6 : response time of 900 ms
1 : NPN output Normally Open (NO)
Sensors from the new range can be mounted on the FIL CONTROL standard rail (ref. : 423800), by the
mean of bracket (ref. : 423802).
FIL CONTROL - SA au capital de 114 336.76 Euros - Le Plantier - F - 16220 MONTBRON
Téléphone : ++ 33 (0) 545 239 502 - Télécopie :++ 33 (0) 545 239 385 - E.Mail : [email protected] - Site Web : www.filcontrol.com
TVA Intracom : FR 89 379 592 389 - RCS 379 592 389 00017 - Code APE 295 G - Siège social : Les Loges - F - 86300 Sainte Radegonde
FIL CONTROL REV : 5
FIL CONTROL
Technical characteristics
Parameters
Power supply voltage (V)
Sensor consumption (mA)
Conditions
Min
18
Typ
24
Max
30
Own current consumption at 24 V DC
Indicator light ON and at 25°C. Input and output not
22
25
11,5 14,5
Indicator light OFF connected
Ripple voltage at 100 Hz
Supply voltage peaks < 30 V
80%
Delay between detection and move start (s)
On request
2
Low level output voltage (V)
Output current < 1 A
0,5 1,1
Min. current driven by the output (A)
Voltage at the output < 32 V
1
Max. voltage at the output (V)
50
Logical level on the configuration input (V)
Supply voltage = 24 V
High level
10,7
Low level
3,8
Current in the configuration input (mA)
Supply voltage = 24 V
Low level
5,3
Immunity to the perturbations (kV)
Positive and negative
Injected
4
Inducted
4
Radiated
4
Temperature range (°C)
For storage
-25
85
For operation
0
50
Relative humidity
80%
Setting up procedure
Standard connection
VCC
Standard configuration
Output NPN-NO
VCC
VCC or power supply
VCC or power supply
5
2
Load
Sensor
Load
Sensor
1
3
Switch
0V
0V
1 : External programming or inhibition input
2 : NPN output
Presence of yarn(s)
Global Operations
LED
Output
If external control input :
Programmation
Switch-on
Inhibition
Presence of 1 yarn
Light-on
Light-on
Light-off
Inactive
Inactive
Inactive
X
X
Low level (0V)
Presence of 2 yarns
Absence of a yarn(s)
Light-off
Blinking
Inactive
Active
High level (24V)
X
State
X : any state.
Fil Control is not liable for any errors or omissions this document may be contain, or for any damage resulting from this application or of the information
herein. Fil Control reserves the right to change the specifications of its products at any time without notice.